品質等級
化驗
99%
形狀
liquid
折射率
n20/D 1.305 (lit.)
bp
142 °C (lit.)
密度
1.93 g/mL at 25 °C (lit.)
官能基
bromo
fluoro
SMILES 字串
FC(F)(F)C(F)(F)C(F)(F)C(F)(F)C(F)(F)C(F)(F)C(F)(F)C(F)(F)Br
InChI
1S/C8BrF17/c9-7(22,23)5(18,19)3(14,15)1(10,11)2(12,13)4(16,17)6(20,21)8(24,25)26
InChI 密鑰
WTWWXOGTJWMJHI-UHFFFAOYSA-N
尋找類似的產品? 前往 產品比較指南
訊號詞
Warning
危險聲明
危險分類
Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3
標靶器官
Respiratory system
儲存類別代碼
10 - Combustible liquids
水污染物質分類(WGK)
WGK 3
閃點(°F)
Not applicable
閃點(°C)
Not applicable
個人防護裝備
Eyeshields, Gloves, type ABEK (EN14387) respirator filter
客戶也查看了
Odile Diou et al.
European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V, 87(1), 170-177 (2013-12-18)
PEGylated polyester nanocapsules of perfluorooctyl bromide (PFOB) were surface-decorated with a RGD (arginine-glycine-aspartic acid) peptide by either pre-functionalization or post-functionalization strategies using carbodiimide-assisted chemistry. Both strategies allowed successful linkage of RGD at the surface of nanocapsules with up to 600-950
Sheng Wang et al.
Nan fang yi ke da xue xue bao = Journal of Southern Medical University, 31(10), 1718-1720 (2011-10-27)
To investigate the effect of temperature on the partition coefficient of isoflurane and sevoflurane in perflurocarbonate emulsion (Oxygent(TM)). The partition coefficients of isoflurane and sevoflurane in perflurocarbonate emulsion (Oxygent(TM)) were measured at different temperatures (4, 22, 27, 32 and 37
Dorota Bartusik et al.
Journal of pharmaceutical and biomedical analysis, 51(4), 894-900 (2009-11-10)
The aim of this study was to assess the herceptin efficacy in ex vivo cultures of MCF-7 breast carcinoma cells. Herceptin was used with perfluorooctyl bromide (PFOB) and conjugated with lipoplex, containing plasmid DNA and lipofectamine (LipA), to allow fluorine-19
Céline Giraudeau et al.
NMR in biomedicine, 25(4), 654-660 (2011-09-29)
We have recently developed an optimized multi-spin echo (MSE) sequence dedicated to perfluorooctyl bromide (PFOB) imaging yielding an excellent sensitivity in vitro. The aim of the present study was to apply this sequence to quantitative measurements in the mouse liver
Alexander-Wigbert K Scholz et al.
Anesthesia and analgesia, 110(6), 1661-1668 (2010-05-08)
Functional magnetic resonance imaging (fMRI) of fluorine-19 allows for the mapping of oxygen partial pressure within perfluorocarbons in the alveolar space (Pao(2)). Theoretically, fMRI-detected Pao(2) can be combined with the Fick principle approach, i.e., a mass balance of oxygen uptake
Active Filters
我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.
聯絡技術服務