If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf
推薦產品
蒸汽壓力
17 mmHg ( 20 °C)
形狀
beads
柱尺寸
17 mm × 240 mm
SMILES 字串
[Al]21O[Al](O2)O1
InChI
1S/2Al.3O
InChI 密鑰
TWNQGVIAIRXVLR-UHFFFAOYSA-N
尋找類似的產品? 前往 產品比較指南
一般說明
• 用于需要在使用前除去稳定剂或抑制剂(氢醌 (HQ)、对苯二酚单甲醚(MEHQ、4-甲氧基苯酚)或 4-叔丁基邻苯二酚 (TBC))的应用。
• 使用后填充柱可丢弃1,或用新的填充料填充全部容量的大约 3/4 即可再次使用。HQ/MEHQ 柱再填充量:约 21g。TBC 柱再填充量:约 30g。
• 近似柱容量:
HQ/MEHQ:3L (100ppm)
TBC:4L (15ppm)
• 建议不要将 TBC 柱和填充料用于极性溶剂,包括丙烯酸。建议这些应用中采用真空蒸馏。
操作简便:
1. 建议用少量单体预清洗预包装玻璃柱。
2.将单体(或溶剂)加入固定在柱上方的加料漏斗中。
3.将单体逐滴加入柱中。注意滴加速度,防止溢出柱。用适当的容器收集单体。
4.对于低熔点固态单体,使用过程中使柱温保持在熔点以上。
小心:过热可能使单体在柱上发生聚合。粘稠或高熔点单体应当用适当的溶剂稀释后再加入柱。
1未使用的柱可随固体化学废物一起丢弃。用过的填充料或填充柱应考虑单体(即将除去其中的抑制剂)的毒性和危害,再决定如何处理。
儲存類別代碼
11 - Combustible Solids
水污染物質分類(WGK)
WGK 3
閃點(°F)
Not applicable
閃點(°C)
Not applicable
個人防護裝備
Eyeshields, Gloves, type N95 (US)
客戶也查看了
文章
An article regarding common FAQs for initiators and stabilizers.
一篇有關啟動劑和穩定劑常見問題的文章。
-
How can I determine the shelf life / expiration / retest date of this product?
1 answer-
Helpful?
-
-
How is shipping temperature determined? And how is it related to the product storage temperature?
1 answer-
Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf
Helpful?
-
-
Would these work for removal of Topanol A, 2,4-Dimethyl-6-tert-butylphenol CAS Number:1879-09-0?
1 answer-
This product is not tested for removal of Topanol A, but is expected to be suitable. The product is used for inhibitor removal for product 276685. Methacrylic anhydride, which contains 2,000 ppm Topanol A as inhibitor.
Helpful?
-
-
Which side of the column is the top versus the bottom?
1 answer-
The label is placed at the top of the column and will include the lot number. The column is provided with a cap on each end; these caps would need to be removed when the column is in use, but replaced between uses.
The glass wool plugs are present to hold the beads inside the column. Initially, a small volume of liquid will wet the glass wool. As more volume is added, the column will become saturated and then eventually pass through and out at the bottom of the column.
Helpful?
-
-
Can Product 306312, Inhibitor removers - Prepacked column for removing hydroquinone and monomethyl ether hydroquinone, be used to remove butylated hydroxytoluene (BHT)?
1 answer-
This inhibitor remover is not intended to remove BHT present in a monomer solution; little, if any, BHT will be removed with this column. Unfortunately, Sigma-Aldrich does not currently offer a inhibitor-remover column that will accomplish this purpose.
Helpful?
-
-
How much can Product 306312, Inhibitor removers - Prepacked column for removing hydroquinone and monomethyl ether hydroquinone, hold at one time?
1 answer-
This product has a bed volume of approximately 30 mL.
Helpful?
-
-
Can Product 306312, Inhibitor removers - Prepacked column for removing hydroquinone and monomethyl ether hydroquinone, be used more than once?
1 answer-
This pre-packed inhibitor remover column is meant for single use but can be rinsed and reused. If time will pass between uses, this column can be rinsed with methanol, dried, capped on both ends, and stored in a tightly sealed plastic bag in the freezer at -20°C.
Helpful?
-
-
What is the flow rate for Product 306312, Inhibitor removers - Prepacked column for removing hydroquinone and monomethyl ether hydroquinone?
1 answer-
According to the manufacturer of this inhibitor removal column, the maximum recommended flow rate is 4 bed volumes (approximately 120 mL) per hour.
Helpful?
-
-
What is the Department of Transportation shipping information for this product?
1 answer-
Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.
Helpful?
-
Active Filters
我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.
聯絡技術服務