跳转至内容
Merck

MAK309

Sigma-Aldrich

胆汁酸检测试剂盒

sufficient for 100 fluorometric tests

别名:

胆汁酸定量试剂盒

登录查看公司和协议定价

选择尺寸

1 KIT
$1,020.00

$1,020.00


国内现货,预计发货时间2025年4月09日详情


获取大包装报价

选择尺寸

变更视图
1 KIT
$1,020.00

About This Item

UNSPSC代码:
12161503
NACRES:
NA.84

$1,020.00


国内现货,预计发货时间2025年4月09日详情


获取大包装报价

检测方法

fluorometric

相关疾病

gastrointestinal diseases; cancer; cardiovascular diseases

储存温度

−20°C

一般描述

通常在哺乳动物中发现十二种不同类型的胆汁酸,其中两种主要类型是胆酸和鹅去氧胆酸。[1]这些可以脱羟基成次级胆汁酸。最后,这四种可以与牛磺酸或甘氨酸结合,产生 8 种不同的结合胆汁酸。粪便、血液、尿液和胆汁中的胆汁酸水平可用作各种疾病的标志物,例如高脂血症、胆汁淤积、胆结石、结肠癌等。[2][3]胆汁酸也以硫酸盐形式存在,称为胆汁酸硫酸盐。胆汁酸的硫酸化增加了它们的溶解度,并减少了肠道吸收,从而增强了粪便和尿液的排泄。

应用

胆汁酸检测试剂盒已被用于量化血浆中的胆汁酸水平。[4]

特点和优势

兼容高通量处理系统。

适用性

适用于总胆汁酸的定量测定和药物对血清、血浆、尿液和其他生物样品中胆汁酸代谢的影响评估。

原理

该胆汁酸检测试剂盒提供了一种方便的荧光测定方法来测量生物样品中的总胆汁酸。在该检测中,3-羟基类固醇脱氢酶与所有十二种胆汁酸反应,将 NAD 转化为 NADH,这将探针还原为高度荧光的产物。得到的荧光强度(γex = 530 nm/γem = 585 nm)与样品中的胆汁酸浓度成线性关系。

储存分类代码

10 - Combustible liquids


历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Tarek Besheer et al.
The Turkish journal of gastroenterology : the official journal of Turkish Society of Gastroenterology, 29(3), 299-307 (2018-05-15)
Chronic hepatitis C (CHC)-related mortality generally results from cirrhosis and subsequent complications. We aimed to investigate the potential role of plasma bile acid levels and ABCB11 1331T > C (V444A, rs2287622) (ATP-binding cassette subfamily B, member 11) gene polymorphism in
Approach to a patient with elevated serum alkaline phosphatase.
Siddique A and Kris V K
Clinics in Liver Disease, 16(2), 199-229 (2012)
Ahmed Dawood Mohammed et al.
Nature communications, 13(1), 525-525 (2022-01-28)
Mucosal antibodies maintain gut homeostasis by promoting spatial segregation between host tissues and luminal microbes. Whether and how mucosal antibody responses influence gut health through modulation of microbiota composition is unclear. Here, we use a CD19-/- mouse model of antibody-deficiency
Bile acids: chemistry, physiology, and pathophysiology.
Monte M J, et al.
World Journal of Gastroenterology, 15(7), 804-804 (2009)
Hung Phuc Nguyen et al.
Journal of animal science, 98(12) (2020-11-18)
A 16-wk growth trial was conducted to examine the effects of dietary replacement of fish meal by defatted soybean meal (SBM) and fermented soybean meal (FSBM) with taurine supplementation on growth performance, nutrient apparent digestibility coefficient (ADC) and biological parameters

Questions

1–8 of 8 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  3. Is a solid, black round 96-well bottom plate sufficient for the assay, or is a 96-well black plate with a clear bottom necessary?

    1 answer
    1. A black, round-bottom plate can be used for this assay instead of a black, clear-bottom plate. Although there may be slight variations in the standard curve (resulting in a higher slope compared to a black flat-bottom plate), the standard curve remains linear, making the black round-bottom plate suitable for use.

      Helpful?

  4. Is it feasible to dilute mouse plasma 20X for use with the Bile Acid quantification kit (catalog number: MAK309), considering that it requires a significant amount of samples (20 µl per well, in duplicate)?

    1 answer
    1. The sample volume required for Kit MAK309 is optimized as per the specifications provided in the kit bulletin. Diluting the plasma 20X is not advisable as it would result in a loss of assay sensitivity. Upon confirming with the vendor, it was advised that the sample volume can be scaled down to half the volume in each step, with the other components adjusted accordingly. However, diluting the samples is not recommended as it would compromise sensitivity. Alternatively, the assay can be adapted for use in a 384-well plate or a half-area 96-well plate, such as CLS3880, which have smaller well volumes and can accommodate smaller sample volumes. For further details, refer to the Scaling Down Volume Procedure from the Vendor document.

      Helpful?

  5. Can bile acids from HepG2 cell culture supernatants be checked using this kit?

    1 answer
    1. Unfortunately, the kit has not been validated with cell culture supernatant, and there are no relevant citations for this particular use. While the expected level of bile acid in HepG2 cell culture supernatant is unknown, given that significant amounts of unconjugated bile acids are released into the medium of HepG2 cell cultures, the sample might be compatible with the kit. It is advisable to conduct an initial serial dilution of the sample to identify the appropriate dilution factor that yields results within the linear detection range (1-150 uM bile acid). The Sample Blank should be adjusted to accommodate possible interference in the sample matrix. If the initial results are not satisfactory, further dilution of the sample may be necessary.

      Helpful?

  6. Is it possible to use the MAK309 bile acid assay kit to measure unknown quantities of bile acids in a solution, such as NaOH? Would NaOH interfere with the assay, and can standards of known bile acid concentration in the same solution be used to address this?

    1 answer
    1. The MAK309 assay has not been tested in a NaOH solution. It is believed that it should work, but if the NaOH solution is basic, it may interfere with the enzymes in the kit. Neutralizing the pH of the NaOH solution before performing the assay is recommended if possible. Additionally, a test run of the kit could be conducted by preparing the internal standard in NaOH. It is important to use NaOH as the blank instead of water to adjust for any changes in the measured bile acid concentration due to the use of NaOH.

      Helpful?

  7. I am looking for the protocol for this bile acids kits MAK309-1KT

    1 answer
    1. The technical bulletin for the Product MAK309 can be accessed in the DOCUMENTATION section of the Product Detail Page under 'More Documents'. Please see the links below:

      https://www.sigmaaldrich.com/product/sigma/mak309#product-documentation
      https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/350/583/mak309bul.pdf

      Helpful?

  8. Hi, I'm looking for a Bile Acid Assay Kit to detect bile acids in stool. Do you have any information/products that may be useful for this purpose? Thanks, Alicia

    1 answer
    1. Product MAK309, Bile Acid Assay Kit, is a fluorometric assay kit that is suitable for the quantitative determination of total bile acids and evaluation of drug effects on bile acid metabolism in serum, plasma, urine and other biological samples. For assay information, please review this data sheet: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/350/583/mak309bul.pdf

      If you would like to search other options , we also offer product MAK382, Total Bile Acids (TBA) Assay kit (Colorimetric), which is a kit that can detect as little as 1μM of bile acids in biological fluids such as serum, plasma, bile, urine, saliva, etc. For assay information, please review this data sheet: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/401/650/mak382bul-ms.pdf

      Helpful?

Reviews

No rating value

Active Filters

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系客户支持