Quality Segment

autoignition temp.

800 °F

technique(s)

LPLC: suitable

surface area

750 m2/g

matrix

styrene-divinylbenzene

matrix active group

polymer

particle size

20-60 mesh

pore size

~0.98 mL/g pore volume, 100 Å mean pore size

density

1.02 g/mL (true wet)(lit.), 1.08 g/mL (skeletal)(lit.)

separation technique

reversed phase

General description

Nonionic macroreticular resin that adsorbs and releases ionic species through hydrophobic and polar interactions; usually used under isocratic conditions.

Application

Polyaromatic adsorbent for small hydrophobic compounds, surfactants, pharmaceutical manufacturing, phenols, chlorinated organics, pesticide removal and recovery, and organic removal from aqueous food streams.

Other Notes

Hydrophobic polyaromatic resin
Two particle sizes are available:
Mesh 20-60 are Cat. Nos. 20276, 10358, XAD4
Mesh 20-50 is Cat. No. 06444

Legal Information

Amberlite is a trademark of DuPont de Nemours, Inc.

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
103582027606444
particle size

20-60 mesh

particle size

20-60 mesh

particle size

20-60 mesh

particle size

20-60 mesh

separation technique

reversed phase

separation technique

reversed phase

separation technique

reversed phase

separation technique

reversed phase

matrix active group

polymer

matrix active group

polymer

matrix active group

polymer

matrix active group

polymer

pore size

~0.98 mL/g pore volume, 100 Å mean pore size

pore size

~0.98 mL/g pore volume, 100 Å mean pore size

pore size

~0.98 mL/g pore volume, 100 Å mean pore size

pore size

~0.98 mL/g pore volume, 100 Å mean pore size

matrix

styrene-divinylbenzene

matrix

styrene-divinylbenzene

matrix

styrene-divinylbenzene

matrix

styrene-divinylbenzene

form

beads

form

solid

form

solid

form

beads


Still not finding the right product?

Explore all of our products under Amberlite XAD4


Storage Class

11 - Combustible Solids

wgk

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

Eyeshields, Gloves, type N95 (US)



Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library


Related Content


Mariafrancesca Scalise et al.
International journal of molecular sciences, 19(3) (2018-03-03)
The human plasma membrane transporter ASCT2 is responsible for mediating Na- dependent antiport of neutral amino acids. New insights into structure/function relationships were unveiled by a combined approach of recombinant over-expression, site-directed mutagenesis, transport assays in proteoliposomes and bioinformatics. WT
ZhiRong Liu et al.
The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians, 33(4), 693-705 (2018-10-26)
Introduction: We carried out a systematic review and meta-analysis to assess the safety and effectiveness of uterine artery embolization (UAE) compared with conventional hysterectomy on refractory postpartum hemorrhage (PPH).Methods: We searched PubMed, Embase, Chinese National Knowledge Infrastructure database (CNKI), Cochrane
Marlen Kücklich et al.
PloS one, 12(8), e0183440-e0183440 (2017-08-26)
Previous studies showed that olfactory cues are important for mammalian communication. However, many specific compounds that convey information between conspecifics are still unknown. To understand mechanisms and functions of olfactory cues, olfactory signals such as volatile compounds emitted from individuals



Global Trade Item Number

SKUGTIN
XAD4-500G04061838552129
XAD4-1KG04061838552112
06444-500G04061838504593
06444-100G04061838504586
1035804061833665404
2027604061833665589

Questions

1–4 of 4 Questions  
  1. Do usage instructions exist for using this product with assisting the debittering of olives on your side? If so, what is the recommended ratio of resin to brine to olives?

    1 answer
    1. No protocol describing the use of this product to debitter olives is available.

      A literature search shows that Amberlite XAD4 resins have been used for phenolic removal to assist in the debittering processes. Please keep in mind that this product is not food grade and is supplied for research and development purposes. Please review the citation below for more details on this application.

      J. Agric. Food Chem. 2019, 67, 5, 1546–1553
      https://doi.org/10.1021/acs.jafc.8b06014

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  3. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  4. What is the recommended method for cleaning XAD4 before use?

    1 answer
    1. The following pretreatment is recommended:
      1.The adsorbent is shipped as a water-wet product with sodium chloride (NaCl) and sodium carbonate (Na2CO3) salts to prevent bacterial growth. These salts need to be washed from the adsorbent before use, and it is suggested that this be achieved by washing with water at a linear flow rate of 5-10 m/h until the required level is achieved.
      2.For sensitive applications, residual monomeric or oligomeric compounds may need to be removed from the adsorbent.
      3.A regeneration with the proposed regenerant is also recommended before the first service cycle. If the regenerant is an alcohol, it must be displaced with water before the first loading cycle.

      Helpful?