No, all Stericup® and Steritop® devices are Research Use Only.
SEGPU1145
Stericup® E-GP Funnel-less Sterile Vacuum Filtration System
pore size 0.22 μm, polyethersulfone membrane, capacity 1000 mL, 45 mm thread, pack of 12 ea
Synonim(y):
Stericup® E-GP Eco-friendly Filter Unit
Wybierz wielkość
Wybierz wielkość
About This Item
Polecane produkty
Materiały
polyethersulfone membrane
polystyrene bottle
polystyrene funnel(s)
polystyrene housing
Poziom jakości
sterylność
sterile; irradiated
linia produktu
Stericup®
Właściwości
hydrophilic
opakowanie
pack of 12 ea
charakterystyka ekologicznej alternatywy
Waste Prevention
Learn more about the Principles of Green Chemistry.
sustainability
Greener Alternative Product
Parametry
max. temp. at 45 °C
opis
2.4 mL (hold-up volume)
metody
sterile filtration: suitable
Wysokość
220 mm
pojemność
1000 mL
Średnica
11.3 cm
pojemność filtra
1000 mL
śr. filtra
73 mm
powierzchnia filtracyjna
40 cm2
Matryca
Express PLUS™
wielkość porów
0.22 μm pore size
dopasowywanie
inlet thread(s)
45 mm thread
kategoria ekologicznej alternatywy
Warunki transportu
ambient
Opis ogólny
For more information, please visit ACT DATABASE
The Stericup® E and Steritop® E sterile filters are designed as a Greener Alternative for vacuum sterile filtration that significantly reduces plastic and packaging.
This Stericup® E is a 45 mm thread collar which uses a 0.22 μm pore size polyethersulfone (PES) membrane filter unit combined with a 1000 mL receiver flask and cap for processing and storage. The 45 mm thread directly connects to wider neck media bottles (such as Gibco® or glass bottles).
Use only glass or plastic bottles designed for vacuum applications.
Zastosowanie
- Tissue culture media +/- additives
- Buffers
- Biological solutions
Cechy i korzyści
- The filter collar disconnects from the receiver bottle with just a quarter turn—reducing the likelihood of spillage and making it easier to manipulate on the bench or under the hood.
- Bold product identification on the filter collar plainly displays membrane characteristics, including composition and pore size, for rapid, application-appropriate product selection.
- Click seal cap is flanged and modified to enable a firm grip in wet or dry conditions—and a tactile stop confirms secure closure. Worry less about the possibility of spilling or contamination of sterilized contents.
- Frosted, ample writing surface on the receiver bottle and lighter cap color facilitate clear labelling to improve legibility and reduce unreadable smears.
- Click seal cap rests on the side to avoid risk of contamination.
- Receiver bottles are stackable to save storage space.
Informacje prawne
Certyfikaty analizy (CoA)
Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Klienci oglądali również te produkty
Produkty
Evaluation of sterile filtration devices for protein preservation in sterile filtration of cell culture media.
Powiązane treści
Sterylne filtry Stericup® E i Steritop® E pomagają zmniejszyć negatywny wpływ laboratorium na środowisko poprzez znaczne ograniczenie odpadów plastikowych i opakowaniowych. Oba filtry mocuje się bezpośrednio do komercyjnych butelek na pożywki, eliminując plastikowy lejek i usuwając zanieczyszczenia z pożywek i buforów.
Stericup® E and Steritop® E sterile filters help reduce laboratory environmental impact by significantly reducing plastic and packaging waste. Both attach directly to commercial media bottles, eliminating the plastic funnel while they eliminate contaminants from media and buffers.
-
Can Stericup® and Steritop® filters be used to prepare solutions that will be administered to patients?
1 answer-
Helpful?
-
-
What is the maximum vacuum pressure for filtration?
1 answer-
700 mm Hg (27.5” Hg, 0.9 bar) differential vacuum at 25 °C (77 °F)
Helpful?
-
-
What is the difference between classic Stericup® filters and Stericup® “Quick Release” filters?
1 answer-
Stericup® Quick Release, or “QR”, filters feature a connection between funnel filter and receiver bottle that requires only a quarter-turn release to facilitate funnel removal. These filters come fully engaged – there is no need to tighten before use. The receiver bottle cap has flanges on the top surface to improve grip, as well as a positive lock stop to ensure a leak-proof seal with the receiver bottle. Other improvements include a large, frosted writing surface on the receiver bottle and a lighter cap color to facilitate labelling, more prominent volume markings on the filtration funnel and receiver bottle, and a product label with a peel-off lot record strip on the bag for easy viewing in storage.
Helpful?
-
-
What is the expiration date of Stericup® and Steritop® filters?
1 answer-
Typically 3 years from sterilization.
Helpful?
-
-
Can we filter oil-type liquids with Stericup® filters?
Can we filter oil-type liquids with Stericup® filters?
1 answer-
Likely not, due to pore size/possible fouling/chemical compatibility. Refer to our guide, "Chemical compatibility of filter components": https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/302/855/membrane-chemical-compatibility-ds2532en-ms.pdf
Helpful?
-
-
What tubing can be used with Stericup® and Steritop® vacuum filters?
What tubing can be used with Stericup® and Steritop® vacuum filters?
1 answer-
Stericup® and Steritop® filters are fitted with a 1/4” tube adapter. We recommend 3/16 in. (4.8 mm) ID silicone tubing to fit this tube adapter: https://www.sigmaaldrich.com/product/mm/xx7100004
Helpful?
-
-
What is the maximum processing volume for Stericup® and Steritop® filters? Can I add more volume after initial filtration?
1 answer-
All Stericup® and Steritop® filters were developed for single-use application. The maximum volume is dependent on the receiver bottle capacity. Stericup® filters come with a receiver bottle with a specified maximum volume. For Steritop® filters, the maximum recommended volume is 2 L with an appropriate-sized receiver bottle. Larger processing volumes can result in membrane fouling, increase chance of spillage and contamination, and lead to possible airlock*.
*Note that devices with PES membranes can airlock if filtered to dryness. Some liquid must be left on top of the filter, then the system stopped, receiver changed or emptied, and more sample volume added before restart. This increases the chance of spillage.Helpful?
-
-
Can Stericup® and Steritop® filters be reused?
1 answer-
All Stericup® and Steritop® filters were developed for single use, disposable processing.
Helpful?
-
-
The User Guide says “Use only glass or plastic bottles designed for vacuum applications”. Can you specify which bottles are compatible?
1 answer-
Steritop® Quick Release bottle top units require a vacuum-rated receiver bottle with either a GL33 or GL45 mm closure thread as specified. Steritop® E bottle top units require a vacuum-rated receiver bottle with a GL45 mm closure thread. Bottles no larger than 2 L should be used.
Glass bottles, GL33:
• Wheaton media bottles (glass), 500 mL (Product Z364886)
• Wheaton media bottles (glass), 1 L (Product Z364894)
Glass bottles, GL45
• Corning® glass media storage bottle, 125 mL (Product CLS1399125)
• Corning® glass media storage bottle, 250 mL (Product CLS1399250)
• Corning® glass media storage bottle, 500 mL (Product CLS1399500)
• Corning® glass media storage bottle, 1 L (Product CLS13991L)
• Pyrex® round media storage bottle, 500 mL (Product CLS1395500)
• Pyrex® round media storage bottle, 1 L (Product CLS13951L)
• KIMBLE® KIMAX® Media bottle, 250 mL (Product DWK14395250)
• KIMBLE® KIMAX® Media bottle, 500 mL (Product DWK14395500)
• KIMBLE® KIMAX® Media bottle, 1 L (Product DWK143951000)
Plastic (pre-sterile) bottles, GL45:
• Stericup® Quick Release Receiver flask, 250 mL (Product S200B02RE)
• Stericup® Quick Release Receiver flask, 500 mL (Product S200B05RE)
• Stericup® Quick Release Receiver flask, 1000 mL (Product S200B10RE)Helpful?
-
-
What Bacterial Endotoxins Test is used?
1 answer-
The test method used complies with USP 85 and EP 2.6.14 to ensure the absence of endotoxin in our products.
Helpful?
-
Active Filters
Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.
Skontaktuj się z zespołem ds. pomocy technicznej