Millipore Express® SHR High Area with prefilter 0.5/0.1µm, Opticap® XLT 30 Capsule

Fittings 1-1/2 in. TC, Gamma Compatible

Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych


About This Item

Kod UNSPSC:
23151806

Nazwa produktu

Millipore Express® SHRP High Area, Opticap® XLT Capsule, Opticap® XLT 30, cartridge nominal length 30 in. (75 cm), filter diam. 4.2 in. (10.7 cm)

Materiały

polyester support
polypropylene housing
silicone seal
vent cap (gamma stable polypropylene)

Poziom jakości

zgodność regionalna

meets FDA 21 CFR 177-182 (all component materials)

sterylność

non-sterile

Kompatybilność ze sterylizacją

gamma compatible

linia produktu

Opticap® XLT 30

Właściwości

hydrophilic

producent / nazwa handlowa

Millipore Express®

Parametry

≤162.6 mL/min air diffusion at 3.45 bar (50 psig) (in water)
1 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet pressure
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 25 °C (intermittent)
80 psig max. inlet pressure

metody

sterile filtration: suitable

Długość

34.3 in.

Szerokość

7.8 in.

długość nominalna kartridża

30 in. (75 cm)

śr. filtra

4.2 in. (10.7 cm)

rozmiar filtra

30 in.

powierzchnia filtracyjna

3.0 m2

zanieczyszczenia

≤0.25 EU/mL bacterial endotoxins (LAL test, aqueous extraction)

Matryca

Millipore Express® SHR ((w/Prefilter High Area))

pore size

0.5/0.1 μm pore size

punkt pęcherzykowania

≥2586 mbar (37.5 psig), nitrogen with 70/30% IPA/water

dopasowywanie

1/4 in. drain/vent connection ( hose barb with double o-ring seal)
(38 mm (1 1/2 in.) Sanitary Flange Inlet and Outlet)

Zastosowanie

filtration

Szukasz podobnych produktów? Odwiedź Przewodnik dotyczący porównywania produktów

Opis ogólny

Device Configuration: Capsule

Cechy i korzyści

T-line/Gauge Port: T-line

Opakowanie

Double Easy-Open bag

Uwaga dotycząca przygotowania

Sterilization Method: Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min at 123 °C; not in-line steam sterilizable

This product was manufactured with a MILLIPORE EXPRESS® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Komentarz do analizy

Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥6 L

TOC/Conductivity: After sterilization and a controlled water flush of 60 L, samples exhibited <500 ppb TOC per USP 643 and <1.3 μS/cm per USP 645 at 25 °C.

Bacterial Retention: Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 107 CFU/cm2 using ASTM® F838 methodology.

Inne uwagi

Directions for Use
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer wetting instructions of Filters with MILLIPORE EXPRESS® Membrane user guide
  • Storage Statement: Please refer Filters with MILLIPORE EXPRESS® Membrane user guide
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

Informacje prawne

ASTM is a registered trademark of American Society for Testing and Materials
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany
Ta strona może zawierać tekst przetłumaczony maszynowo.

Certyfikaty analizy (CoA)

Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej