KHVEG3TTT1H
Millipore Express® SHR High Area with prefilter 0.5/0.1µm, Opticap® XLT 30 Capsule
Fittings 1-1/2 in. TC, Gamma Compatible
About This Item
Nazwa produktu
Millipore Express® SHRP High Area, Opticap® XLT Capsule, Opticap® XLT 30, cartridge nominal length 30 in. (75 cm), filter diam. 4.2 in. (10.7 cm)
Materiały
polyester support
polypropylene housing
silicone seal
vent cap (gamma stable polypropylene)
Poziom jakości
zgodność regionalna
meets FDA 21 CFR 177-182 (all component materials)
sterylność
non-sterile
Kompatybilność ze sterylizacją
gamma compatible
linia produktu
Opticap® XLT 30
Właściwości
hydrophilic
producent / nazwa handlowa
Millipore Express®
Parametry
≤162.6 mL/min air diffusion at 3.45 bar (50 psig) (in water)
1 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet pressure
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 25 °C (intermittent)
80 psig max. inlet pressure
metody
sterile filtration: suitable
Długość
34.3 in.
Szerokość
7.8 in.
długość nominalna kartridża
30 in. (75 cm)
śr. filtra
4.2 in. (10.7 cm)
rozmiar filtra
30 in.
powierzchnia filtracyjna
3.0 m2
zanieczyszczenia
≤0.25 EU/mL bacterial endotoxins (LAL test, aqueous extraction)
Matryca
Millipore Express® SHR ((w/Prefilter High Area))
pore size
0.5/0.1 μm pore size
punkt pęcherzykowania
≥2586 mbar (37.5 psig), nitrogen with 70/30% IPA/water
dopasowywanie
1/4 in. drain/vent connection ( hose barb with double o-ring seal)
(38 mm (1 1/2 in.) Sanitary Flange Inlet and Outlet)
Zastosowanie
filtration
Szukasz podobnych produktów? Odwiedź Przewodnik dotyczący porównywania produktów
Opis ogólny
Cechy i korzyści
Opakowanie
Uwaga dotycząca przygotowania
This product was manufactured with a MILLIPORE EXPRESS® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).
Komentarz do analizy
TOC/Conductivity: After sterilization and a controlled water flush of 60 L, samples exhibited <500 ppb TOC per USP 643 and <1.3 μS/cm per USP 645 at 25 °C.
Bacterial Retention: Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 107 CFU/cm2 using ASTM® F838 methodology.
Inne uwagi
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer wetting instructions of Filters with MILLIPORE EXPRESS® Membrane user guide
- Storage Statement: Please refer Filters with MILLIPORE EXPRESS® Membrane user guide
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations
Informacje prawne
Certyfikaty analizy (CoA)
Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.
Skontaktuj się z zespołem ds. pomocy technicznej