KHGLG10HH1
Multilayer Durapore® 0.45/0.22 µm, Opticap® XL Capsule
inlet connection diam. 9/16 in., Opticap® XL 10, pore size 0.45/0.22 μm, cartridge nominal length 10 in. (25 cm)
Synonim(y):
Opticap Gamma Compatible Multilayer XL10 Durapore 0.45/0.22 μm 9/16 in. HB/HB
About This Item
Polecane produkty
Materiały
PVDF
polyester support
polyethylene support
polypropylene
polypropylene housing
polypropylene vent cap
silicone outer O-ring
silicone-coated EPDM rubber lead O-ring
Poziom jakości
zgodność regionalna
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
sterylność
non-sterile
Kompatybilność ze sterylizacją
gamma compatible
linia produktu
Opticap® XL 10
Właściwości
gamma compatible
hydrophilic
producent / nazwa handlowa
Opticap®
Parametry
≤15.0 mL/min air diffusion at 2.75 bar (40 psig) and 23 °C (in water)
1.0 bar max. inlet pressure (15 psi) at 80 °C
1.05 bar max. differential pressure (15 psid) at 80 °C (Forward)
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
3.5 bar max. differential pressure (50 psid) at 25 °C (Reverse; intermittent)
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 23 °C
80 psig max. inlet pressure
metody
sterile filtration: suitable
Długość
33.5 cm (13.2 in.)
Szerokość
4.2 in.
długość nominalna kartridża
10 in. (25 cm)
Średnica
10.7 cm (4.2 in.)
powierzchnia filtracyjna
0.6 m2
śr. przyłącza doprowadzającego
9/16 in.
szer. od złącza doprowadzającego do złącza odprowadzającego
33.5 cm (13.2 in.)
śr. przyłącza odprowadzającego
9/16 in.
zanieczyszczenia
≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
macierz
Multilayer Durapore®
pore size
0.45/0.22 μm pore size
moc wejściowa
sample type liquid
punkt pęcherzykowania
≥3450 mbar (50 psig), air with water at 23 °C
dopasowywanie
1/4 in. drain/vent hose barb (with double O-ring Seal)
inlet hose barb
outlet hose barb
(14 mm (9/16 in.) Hose Barb Inlet and Outlet)
Opis ogólny
Opakowanie
Inne uwagi
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer Wetting Instructions for Filter Units with Durapore® Membrane user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Uwaga dotycząca przygotowania
Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
Komentarz do analizy
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
After sterilization and a controlled water flush, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 ºC.
Informacje prawne
Oświadczenie o zrzeczeniu się odpowiedzialności
Not finding the right product?
Try our Narzędzie selektora produktów.
Certyfikaty analizy (CoA)
Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.
Skontaktuj się z zespołem ds. pomocy technicznej