Przejdź do zawartości
Merck

CHGE75TE3

Millipore

Millipore Express® SHC 0.5/0.2µm Cartridge 5

Code 7 EPDM, Autoclavable and SIP

Synonim(y):

Millipore Express SHC Cartridge Filter 5 in. 0.5/0.2 μm Code 7 EPDM

Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych

Wybierz wielkość

3 EA
4980,00 zł

4980,00 zł


Przewidywany termin wysyłki10 kwietnia 2025Szczegóły



Wybierz wielkość

Zmień widok
3 EA
4980,00 zł

About This Item

Kod UNSPSC:
23151806
eCl@ss:
32031690

4980,00 zł


Przewidywany termin wysyłki10 kwietnia 2025Szczegóły


Nazwa produktu

Millipore Express® SHC, Cartridge, pore size 0.5/0.2 μm, cartridge nominal length 5 in. (12.5 cm), Code 7, EPDM rubber seal

Materiały

EPDM rubber seal
polyethersulfone
polypropylene
polypropylene support
polysulfone

Poziom jakości

zgodność regionalna

meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

sterylność

non-sterile

Kompatybilność ze sterylizacją

autoclavable compatible
steam-in-place compatible

linia produktu

EMPROVE® Filter
Millipore Express®

Właściwości

hydrophilic

producent / nazwa handlowa

Millipore Express®

Parametry

≤13.3 mL/min air diffusion at 2.8 bar (40 psig) and 23 °C (in water)
0.07 bar max. inlet pressure (1 psi) at 135 °C (Reverse)
1.0 bar max. inlet pressure (15 psi) at 135 °C (Forward)
1.7 bar max. inlet pressure (25 psi) at 80 °C (Forward)
1700 bar max. differential pressure (25 psi) at 80 °C (Forward)
2.07 bar max. inlet pressure (30 psi) at 25 °C (Reverse)
2100 mbar max. differential pressure (30 psi) at 25 °C (Reverse)
340 mbar max. differential pressure (5 psi) at 135 °C (Forward)
69 mbar max. differential pressure (1 psi) at 135 °C (Reverse)
6900 mbar max. differential pressure (100 psi) at 25 °C (Forward)
7 bar max. inlet pressure (100 psi) at 25 °C (Forward)

metody

sterile filtration: suitable

Długość

5 in.

Szerokość

2.75 in.

długość nominalna kartridża

5 in. (12.5 cm)

Średnica

6.9 cm (2.7 in.)

powierzchnia filtracyjna

0.23 m2

zanieczyszczenia

≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

Matryca

Millipore Express® SHC

pore size

0.5/0.2 μm pore size

moc wejściowa

sample type liquid

punkt pęcherzykowania

≥4000 mbar (58 psig), air with water at 23 °C

kod wkładu

Code 7

Opis ogólny

Millipore Express® SHC filters have an on-board polyethersulfone membrane prefilter which protects the 0.2 μm membrane from premature plugging and extends filtration capacity, so you get sterilizing-grade performance with superior throughput. The CHGE75TE3 cartridge filter features a 0.5/0.2 μm pore size, a filtration area of 0.23 m2 and a Code 7 cartridge configuration.

Millipore Express® SHC filters provide you with a single solution for a range of process fluids, minimizing validation efforts and simplifying filter inventory and stocking requirements. With Millipore Express® SHC filters, you increase productivity, shorten cycle-time and reduce cost.

Zastosowanie

  • Media additives
  • Column protection
  • Concentrated protein streams
  • Cell harvest (post clarification)
  • Caustics/pH adjusters
  • Buffers
  • CIP solution

Cechy i korzyści

  • High capacity, high flux hydrophilic PES membranes
  • Validated sterilizing-grade performance
  • Easy wetting and integrity testing
  • Superior throughput in high fouling streams, including media and protein containing solutions
  • Increased capacity for improved process efficiency and economy
  • Broad chemical compatibility across a wide pH range (1-14) — caustic compatible

Opakowanie

Double Easy-Open bag

Inne uwagi

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Directions for Use

  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer wetting instructions of Filters with MILLIPORE EXPRESS® Membrane user guide
  • Storage Statement: Please refer Filters with MILLIPORE EXPRESS® Membrane user guide
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Uwaga dotycząca przygotowania

Sterilization Method
25 forward or 22 forward and 3 reverse SIP cycles of 30 min @ 135 °C and 0.35 bar (5) or 3 forward SIP cycles of 30 min @ 135 °C and 1 bar (15 psid); 25 autoclave cycles of 60 min @ 126 °C
This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Komentarz do analizy

Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
TOC/Conductivity
After sterilization and a controlled water flush of 9.5 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥2 L

Informacje prawne

ASTM is a registered trademark of American Society for Testing and Materials
Emprove is a registered trademark of Merck KGaA, Darmstadt, Germany
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany
Ta strona może zawierać tekst przetłumaczony maszynowo.

Czym jest program Emprove®?

Program Emprove® jest systemem zapewniającym kompleksową i dokładną dokumentację naszych filtrów i komponentów jednorazowego użytku, surowców farmaceutycznych oraz materiałów wsadowych.

Material Qualification Dossier

Bezpłatnie – Zaloguj się, aby pobrać

Quality Management Dossier (Open Access)

Bezpłatnie – Zaloguj się, aby pobrać

Operational Excellence Dossier

Dostępne w ramach subskrypcji lub za opłatą

Dowiedz się więcej o korzyściach płynących z subskrypcji programu Emprove®
Dlaczego te dokumenty są niedostępne?
Dokumentacja Emprove® zawiera informacje poufne, a także informacje mające na celu wsparcie producentów farmaceutyków w procesie rejestracji i oceny ryzyka. Jeśli chcesz uzyskać dostęp, skontaktuj się z nami.

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

Questions

Reviews

No rating value

Active Filters

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej