Przejdź do zawartości
Merck

GF61141621

Tantalum

rod, 100mm, diameter 1.5mm, annealed, 99.9%

Synonim(y):

Tantalum, TA007915, Ta

Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych


About This Item

Wzór empiryczny (zapis Hilla):
Ta
Numer CAS:
Masa cząsteczkowa:
180.95
Numer MDL:
Kod UNSPSC:
12141741
Identyfikator substancji w PubChem:
NACRES:
NA.23

ciśnienie pary

<0.01 mmHg ( 537.2 °C)

Próba

99.9%

Postać

rod

temp. samozapłonu

572 °F

producent / nazwa handlowa

Goodfellow 611-416-21

rezystywność

13.5 μΩ-cm, 20°C

dł. × śr.

100 m × 1.5 mm

tw

5425 °C (lit.)

mp

2996 °C (lit.)

gęstość

16.69 g/cm3 (lit.)

ciąg SMILES

[Ta]

InChI

1S/Ta

Klucz InChI

GUVRBAGPIYLISA-UHFFFAOYSA-N

Opis ogólny

For updated SDS information please visit www.goodfellow.com.

Informacje prawne

Product of Goodfellow
This page may contain text that has been machine translated.

Wybierz jedną z najnowszych wersji:

Certyfikaty analizy (CoA)

Lot/Batch Number

Przepraszamy, ale COA dla tego produktu nie jest aktualnie dostępny online.

Proszę o kontakt, jeśli potrzebna jest pomoc Obsługa Klienta

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

[Tantalum dust as a contrast substance for laryngography and bronchography (a review of the literature)].
R M Rabinovich
Vestnik rentgenologii i radiologii, (1)(1), 77-79 (1981-01-01)
Xiao-kang Tang et al.
Zhongguo gu shang = China journal of orthopaedics and traumatology, 26(7), 617-620 (2013-10-19)
Incorrect treatment for femur head necrosis can cause collapse of femoral head and tresult in severe harm for the patients (especially for the patient with middle-aged and young). The structure and mechanics characteristics of tantalum rod is similar to bone
Clinical use of porous tantalum in complex primary total knee arthroplasty.
Neil P Sheth et al.
American journal of orthopedics (Belle Mead, N.J.), 38(10), 526-530 (2009-12-17)
Ulrich Dorn et al.
The Journal of arthroplasty, 29(4), 831-835 (2013-10-09)
This study compared the corrosion behavior of tantalum-coated cobalt-chromium modular necks with that of titanium alloy modular necks at their junction to titanium-alloy femoral stem. Tests were performed in a dry assembly and two wet assemblies, one contaminated with calf
Metallosis and elevated serum levels of tantalum following failed revision hip arthroplasty--a case report.
George C Babis et al.
Acta orthopaedica, 85(6), 677-680 (2014-08-21)

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej