Przejdź do zawartości
Merck

GF60379982

Lead

foil, 0.5m coil, thickness 1.0mm, as rolled, 99.5%

Synonim(y):

Lead, PB000413

Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych


About This Item

Wzór empiryczny (zapis Hilla):
Pb
Numer CAS:
Masa cząsteczkowa:
207.20
Numer MDL:
Kod UNSPSC:
12141723
Identyfikator substancji w PubChem:
NACRES:
NA.23

Próba

99.5%

Postać

foil

producent / nazwa handlowa

Goodfellow 603-799-82

rezystywność

20.65 μΩ-cm

śr. × grubość

0.5 m × 1 mm

tw

1740 °C (lit.)

mp

327.4 °C (lit.)

ciąg SMILES

[Pb]

InChI

1S/Pb

Klucz InChI

WABPQHHGFIMREM-UHFFFAOYSA-N

Opis ogólny

For updated SDS information please visit www.goodfellow.com.

Informacje prawne

Product of Goodfellow
This page may contain text that has been machine translated.

Piktogramy

Health hazardEnvironment

Hasło ostrzegawcze

Danger

Zwroty wskazujące rodzaj zagrożenia

Zwroty wskazujące środki ostrożności

Klasyfikacja zagrożeń

Aquatic Acute 1 - Aquatic Chronic 1 - Lact. - Repr. 1A - STOT RE 1 Oral

Organy docelowe

Central nervous system,Blood,Immune system,Kidney

Kod klasy składowania

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

Klasa zagrożenia wodnego (WGK)

nwg

Temperatura zapłonu (°F)

Not applicable

Temperatura zapłonu (°C)

Not applicable


Wybierz jedną z najnowszych wersji:

Certyfikaty analizy (CoA)

Lot/Batch Number

Przepraszamy, ale COA dla tego produktu nie jest aktualnie dostępny online.

Proszę o kontakt, jeśli potrzebna jest pomoc Obsługa Klienta

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

Motoaki Kato et al.
Nihon Hoshasen Gijutsu Gakkai zasshi, 61(8), 1158-1169 (2005-09-01)
In projection radiography, stationary grids are indispensable accessories to the improvement of diagnostic imaging. On the other hand, they are becoming one of the issues facing digital image processing. The lead foil that composes the grid can produce moiré on
M Bourgeois et al.
Health physics, 62(6), 546-552 (1992-06-01)
A significant amount of radiation escapes the rear of an image receptor in conventional dental radiographic procedures despite the placement of a lead-containing backing at the rear of the film pack. The purpose of this investigation was to place additional
D W Rogers
Medical physics, 26(4), 533-537 (1999-05-05)
Data are presented to allow the photon beam quality specifier being used in the new AAPM TG-51 protocol, %dd(10)x, to be extracted from depth-dose data measured with a 1 mm lead foil either 50 cm or 30 cm from the
George X Ding
Medical physics, 29(11), 2459-2463 (2002-12-05)
This study investigates a possible cause of reported significant dose discrepancies between Monte Carlo calculations and measurements in the buildup region for high-energy photon beams in large fields. A proposed hypothesis was that the discrepancy was caused by a source
I Sewerin
Tandlaegebladet, 94(12), 483-486 (1990-09-01)
The lead foil of dental x-ray film packets may cause a number of artifacts; especially well known are the "tractor treads" and "herringbone patterns" following a backward filmpositioning in the patient's mouth. In the present paper a specific and seldomly

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej