  • Fast determination of 22 sulfonamides from chicken breast muscle using core-shell nanoring amino-functionalized superparamagnetic molecularly imprinted polymer followed by liquid chromatography-tandem mass spectrometry.

Fast determination of 22 sulfonamides from chicken breast muscle using core-shell nanoring amino-functionalized superparamagnetic molecularly imprinted polymer followed by liquid chromatography-tandem mass spectrometry.

Journal of chromatography. A (2014-05-02)
Yong-Gang Zhao, Li-Xin Zhou, Sheng-Dong Pan, Ping-Ping Zhan, Xiao-Hong Chen, Mi-Cong Jin
摘要

A novel, simple and sensitive method was developed for the simultaneous determination of 22 sulfonamides (SAs) in chicken breast muscle by using the dispersive micro-solid-phase extraction (d-μ-SPE) procedure combined with ultra-fast liquid chromatography-tandem quadrupole mass spectrometry (UFLC-MS/MS). The excellent core-shell nanoring amino-functionalized superparamagnetic molecularly imprinted polymer (CS-NR-Mag-MIP) was used as sorbent, and the main factors affecting the extraction efficiency were investigated in detail. All target compounds showed good linearities in the tested range with correlation coefficients (r) higher than 0.9980. The mean recoveries were in the range of 85.0-112.2% at low, medium and high concentration levels (0.1, 1.0 and 5.0 ng/g). The intra-day and inter-day relative standard deviations (RSDs) were lower than 6.0% and 8.9%, respectively. The limits of quantification for the 22 SAs were between 0.013 and 0.099 ng/g. The developed d-μ-SPE-UFLC-MS/MS method had been successfully applied to the chicken breast muscle samples for food-safety risk monitoring in Zhejiang Province, China. The results showed sulfamethazine, sulfamethoxazole and sulfaquinoxaline in five out of three hundred collected samples were detected with concentrations of 0.418-2.28, 16.4 and 2.93 ng/g, respectively. It was confirmed that the CS-NR-Mag-MIP was a kind of highly effective d-μ-SPE materials used for the SAs analyses.

材料
货号
品牌
产品描述

Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
乙腈, HPLC Plus, ≥99.9%
Sigma-Aldrich
甲酸, reagent grade, ≥95%
Sigma-Aldrich
甲酸, ACS reagent, ≥96%
Sigma-Aldrich
乙酸铵, ACS reagent, ≥97%
Sigma-Aldrich
甲酸, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥98%
Sigma-Aldrich
乙腈, ACS reagent, ≥99.5%
Sigma-Aldrich
乙酸铵, ≥99.99% trace metals basis
Sigma-Aldrich
乙腈, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
油酸, technical grade, 90%
Sigma-Aldrich
甲基丙烯酸甲酯, contains ≤30 ppm MEHQ as inhibitor, 99%
Sigma-Aldrich
甲酸, puriss., meets analytical specifications of DAC, FCC, 98.0-100%
Sigma-Aldrich
二乙烯基苯, technical grade, 80%
Sigma-Aldrich
甲酸, ACS reagent, ≥88%
Sigma-Aldrich
四乙烯五胺, technical grade
Sigma-Aldrich
乙腈, anhydrous, 99.8%
Sigma-Aldrich
乙酸铵, for molecular biology, ≥98%
Sigma-Aldrich
甲基丙烯酸缩水甘油酯, ≥97.0% (GC)
Sigma-Aldrich
油酸, BioReagent, suitable for cell culture
Sigma-Aldrich
Luperox® A75, 过氧化苯甲酰, 75%, remainder water
Sigma-Aldrich
乙腈, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
乙酸铵 溶液, for molecular biology, 7.5 M
Sigma-Aldrich
氯化铁(III), sublimed grade, ≥99.9% trace metals basis
Sigma-Aldrich
乙腈, biotech. grade, ≥99.93%
Sigma-Aldrich
油酸, natural, FCC
Sigma-Aldrich
氯化铁(III), anhydrous, powder, ≥99.99% trace metals basis
Sigma-Aldrich
甲基丙烯酸缩水甘油酯, 97%, contains 100 ppm monomethyl ether hydroquinone as inhibitor
Sigma-Aldrich
三氯化铁 溶液, purum, 45% FeCl3 basis
Sigma-Aldrich
油酸, meets analytical specification of Ph, Eur., 65.0-88.0% (GC)
Sigma-Aldrich
乙酸铵, 99.999% trace metals basis