제품명

TSKgel® G3000SWXL HPLC Column, phase diol, L × I.D. 30 cm × 7.8 mm, 5 μm particle size

material

stainless steel

Agency

suitable for USP L20
suitable for USP L59

제품 라인

TSKgel®

제조업체/상표

Tosoh 08541

파라미터

≤0.5 M salt concentration
0-100% aqueous soluble organic solvents
1.2 mL/min flow rate
10-30 °C temperature
72 bar max. pressure

기술

HPLC: suitable

길이 × I.D.

30 cm × 7.8 mm

Matrix

silica particle platform

기질 활성군

diol phase

입자 크기

5 μm

공극 크기

250 Å

작동 pH

2.5-7.5

분리 기술

size exclusion (SEC)

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

Widely considered the premium columns for analyzing biopolymers by GFC, TSKgel SWXL columns feature high pore volume per unit column volume, low sample adsorption and excellent column efficiency, all contributing to unsurpassed sample resolution. With 5μm particles and 250Å pores, TSKgel G3000SWXL is an excellent choice for protein and large peptide separations. The fractionation range is applicable for globular protein samples up to 0.5 million Da.

물리적 형태

Shipped in 0.05% NaN3 and 0.1 M Na2SO4 in 0.1 M phosphate buffer, pH 6.7.

추천 제품

Discover LiChropur reagents ideal for HPLC or LC-MS analysis

법적 정보

TSKgel is a registered trademark of Tosoh Corporation

가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 문서 section.

도움이 필요하시면 연락하세요. 고객 지원 부서

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

질문

1–4 / 4 질문  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 답변
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      도움이 되었습니까?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 답변
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      도움이 되었습니까?

  3. Can this column be used on an Aekta system (FPLC)? Or is an HPLC required?

    1 답변
    1. This product is intended for use in HPLC. However, the item may be functional under FPLC conditions with the appropriate ÄKTA adapters.

      도움이 되었습니까?

  4. Dears, Please advise whether or not Pre-column is required to be used with this item (Tosoh G3000 SWXL TSK Gel 7.8 mm x 30 cm, 5 µm)

    1 답변
    1. This product does not require a pre-column, it is used as an analytical column.

      도움이 되었습니까?