Yes, we have guard columns available for Ascentis® Express F5 HPLC Column . Product 53500-U is the Ascentis® Express Guard Holder and Product 53594-U Ascentis® Express F5 Guard Cartridge is a package of three guard cartridges, 2.7 μm particle size, L 5mm × I.D. 2.1 mm .
₩918,778
추천 제품
제품명
Ascentis® Express F5, 2.7 μm HPLC Column, 2.7 μm particle size, L × I.D. 5 cm × 2.1 mm
material
stainless steel column
Agency
suitable for USP L43
제품 라인
Ascentis®
특징
endcapped
제조업체/상표
Ascentis®
포장
1 ea of
파라미터
60 °C temp. range
600 bar max. pressure (9000 psi)
기술
HPLC: suitable
LC/MS: suitable
UHPLC-MS: suitable
UHPLC: suitable
길이 × I.D.
5 cm × 2.1 mm
표면적
135 m2/g
불순물
<5 ppm metals
Matrix
Fused-Core particle platform
superficially porous particle
기질 활성군
PFP (pentafluorophenyl) phase
입자 크기
2.7 μm
공극 크기
90 Å pore size
작동 pH
2-8
응용 분야
food and beverages
분리 기술
reversed phase
유사한 제품을 찾으십니까? 방문 제품 비교 안내
1 of 4
이 품목 | 53581-U | 53579-U | 53568-U |
---|---|---|---|
matrix active group PFP (pentafluorophenyl) phase | matrix active group PFP (pentafluorophenyl) phase | matrix active group PFP (pentafluorophenyl) phase | matrix active group PFP (pentafluorophenyl) phase |
L × I.D. 5 cm × 2.1 mm | L × I.D. 3 cm × 4.6 mm | L × I.D. 15 cm × 3 mm | L × I.D. 7.5 cm × 2.1 mm |
particle size 2.7 μm | particle size 2.7 μm | particle size 2.7 μm | particle size 2.7 μm |
pore size 90 Å pore size | pore size 90 Å pore size | pore size 90 Å pore size | pore size 90 Å pore size |
product line Ascentis® | product line Ascentis® | product line Ascentis® | product line Ascentis® |
일반 설명
법적 정보
가아드 카트리지
관련 제품
애플리케이션
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
가장 최신 버전 중 하나를 선택하세요:
시험 성적서(COA)
문서
This study demonstrates the impact of various mobile phase modifiers on the separation; formate modifiers outperform acetate in terms of MS signals (or sensitivity) and chromatographic resolution.
This article highlights the impact that sample matrix effects can have on LC/MS response and discusses two novel approaches to reduce it.
Enhanced selectivity for stereoisomers and closely related compounds with alternate selectivity from C18 phases for basic, acidic, or neutral compounds
프로토콜
Fast and Accurate LC-MS Analysis of Vitamin D Metabolites, Using Ascentis® Express F5 HPLC Columns from Supelco®
Chromatograms
application for HPLC-
Are guard columns available for Ascentis® Express F5 2.1 mm ID HPLC Columns?
1 답변-
도움이 되었습니까?
-
-
What is the carbon load for Ascentis® Express F5 HPLC Columns?
1 답변-
Carbon load which is commonly referred to as %Carbon is misleading and not meaningful for Ascentis Express. Since Fused-Core™ particle is unique in the sense that it has a solid core and porous shell, the %Carbon number can not be compared to traditional porous particles. The carbon coverage for Ascentis® Express F5 HPLC columns is 3.5 micromoles/meter-squared.
도움이 되었습니까?
-
-
What flow rate should I use with Ascentis® Express F5 HPLC columns?
1 답변-
Based on the minimum in the van Deemter curves, higher flows than 5um particle columns are required in order to maximize Ascentis® Express F5 HPLC column efficiency. The suggested starting point for flow rate for Ascentis® Express columns: 1.6 mL/min for 4.6 mm ID; 0.8 mL/min for 3.0 mm ID; and 0.4mL/min for 2.1 mm ID.
도움이 되었습니까?
-
-
What is the pressure rating for Ascentis® Express F5 HPLC Columns?
1 답변-
Ascentis® Express F5 HPLC Columns are stable to operating pressures up to 600 bar (9000 psi).
도움이 되었습니까?
-
-
How can I measure my instrument bandwidth (IBW) and determine what columns can be used with minimal efficiency loss created by too much internal instrument volume?
1 답변-
The Guide to Dispersion Measurement has simple instructions on how to measure IBW and can be found at sigma-aldrich.com/express.
도움이 되었습니까?
-
-
Do I need special fittings and tubing to connect Ascentis® Express F5 HPLC Columns?
1 답변-
While operating pressures may not exceed the 400 bar (6,000 psi) capability of your traditional instruments, sustained pressures of about 200 bar (3,000 psi) will exceed the recommended pressure for conventional PEEK tubing and fittings at the column inlet. We recommend changing to stainless steel fittings in all high pressure locations and have designed special High Performance HPLC Fittings/Interconnects that will stay tight at pressures of 1,000 bar (15,000 psi) or greater, even when elevated column temperatures are employed.
도움이 되었습니까?
-
-
Can I use Ascentis® Express F5 HPLC Columns on a UHPLC system?
1 답변-
Ascentis® Express F5 HPLC columns are packed in a way making them suitable for these ultra high pressure instruments. In fact, Ascentis® Express F5 HPLC Columns outperform sub-2 μm micron columns on many applications since Ascentis® Express F5 HPLC Columns provide the benefits of sub-2 μm particles but at much lower back pressure. These benefits include the capability of providing fast HPLC and higher resolution chromatography. The Fused-Core particle consists of a 1.7 μm solid core and a 0.5 μm porous shell. A major benefit of the Fused-Core particle is the small diffusion path (0.5 μm) compared to conventional fully porous particles. The shorter diffusion path reduces axial dispersion of solutes and minimizes peak broadening.
도움이 되었습니까?
-
-
Can Ascentis® Express F5 HPLC columns be used for LC-MS?
1 답변-
Yes, Express Fused-Core™ particles were designed with LC-MS in mind. Even extremely short column lengths exhibit sufficient plate counts to show high resolving power. The flat van Deemter plots permit resolution to be maintained at very high flow rates to maximize sample throughput. All Ascentis stationary phases have been evaluated for MS compatibility during their development, and the Express phases are no exception. You can expect extremely low column bleed and background while maintaining longest possible column lifetime. A bonus of Ascentis® Express F5 HPLC Columns for high throughput UHPLC and LC-MS are that they are extremely rugged and highly resistant to plugging, a very common failure mode for competitor columns.
도움이 되었습니까?
-
-
What is the Department of Transportation shipping information for this product?
1 답변-
Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.
도움이 되었습니까?
-
-
Is there anything special I need to do to my HPLC system to use Ascentis® Express F5 HPLC Columns?
1 답변-
Nothing special is required to use Ascentis® Express F5 HPLC Columns. To obtain the full benefits of Ascentis® Express Columns, one should minimize dispersion or instrument bandwidth in the HPLC system (tubing, detector flow cell) as well as confirm the detector response system is set at a fast level. For more information, request Guidelines for Optimizing Performance with Ascentis® Express HPLC Columns (T407102).
도움이 되었습니까?
-