29546-U

Supelco

High Capacity Gas Purifier, Starter Kit

AC/DC input 230 V AC, size 1/8 in., CE Approved

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
41121813
NACRES:
SB.54
가격 및 재고 정보를 현재 이용할 수 없음 고객지원팀으로 연락바랍니다.

크기

1/8 in.

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

Conformity Marks: CE Approved
No other purifier removes both moisture and oxygen in such large quantities (35 liters of moisture, 14 liters of oxygen ).

Protects GC columns and detectors from damage caused by moisture and oxygen in the carrier gas stream, even when present up to 100 ppm levels. The clam-shell oven heats a converter tube to 580°C, causing moisture and oxygen to irreversibly react with the reactant material. This chemical reaction prevents contaminants from returning to the gas stream, even when the material approaches saturation, or when the oven is cooled. Carbon monoxide and carbon dioxide are also removed.

It is recommended to install 4 ft. (1.2 m) of tubing downstream of the oven to allow heat to dissipate from the gas stream. This tubing can be coiled to reduce space.

The starter kit includes a clam-shell oven, two elements (installed), and a converter tube.

Note: Not for use with hydrogen gas.

Clam-Shell Oven:
  • Length: 14 1/2 in. (36.8 cm)
  • Height: 5 1/4 in. (13.3 cm)
  • Depth: 6 in. (15.2 cm)
  • Operating Temp.: 580°C
  • Power Consumption: 90 watt
  • Conformity marks: CE Approved
  • Mounting: Horizontally only (bench or wall) using integral bracket
  • Warranty: 1 year

Converter Tube:
  • Length inside column oven: 10 in. (25.4 cm)
  • Diameter: 1/2 in. (12.7 mm)
  • Max. Inlet Pressure: 150 psi
  • Max. Flow Rate: 1100 mL/min

픽토그램

Flame

신호어

Danger

유해 및 위험 성명서

Hazard Classifications

Flam. Sol. 1

Storage Class Code

4.1B - Flammable solid hazardous materials

WGK

WGK 1

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 문서 section.

도움이 필요하시면 연락하세요. 고객 지원 부서

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

질문

1–2 / 2 질문  
  1. What is the Department of Transportation shipping information for this product?

    1 답변
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      도움이 되었습니까?

  2. Does the High Capacity Gas Purifier contain asbestos?

    1 답변
    1. The High Capacity Gas Purifier does not contain asbestos.

      도움이 되었습니까?

후기

평점 값 없음

활성 필터

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.