콘텐츠로 건너뛰기
Merck
모든 사진(1)

주요 문서

22147-U

Supelco

Gas Sampling Bulb

size 250 mL, glass stopcock

로그인조직 및 계약 가격 보기

크기 선택

1 EA
₩288,768

₩288,768


예상 입고일2025년 4월 21일세부사항


벌크 견적 요청

크기 선택

보기 변경
1 EA
₩288,768

About This Item

UNSPSC 코드:
41104008
NACRES:
NB.24

₩288,768


예상 입고일2025년 4월 21일세부사항


벌크 견적 요청

material

glass stopcock

Quality Level

기술

whole air sampling: suitable

크기

250 mL

응용 분야

air monitoring
environmental
industrial hygiene

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

Use these glass bulbs to trap and transport a gas sample, then remove an aliquot (through the plug-type septum) for analysis. Oven annealed to resist damage during transportation and on-site use. Available with PTFE or high vacuum glass stopcocks. One half-hole cylindrical Thermogreen septum is included with each bulb.

가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 문서 section.

도움이 필요하시면 연락하세요. 고객 지원 부서

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

질문

  1. Good morning, Could you tell me if they have a key with an escape valve for safety? How do I prevent the glass from breaking with the pressure of N2 gas? Thank you!

    1 답변
    1. There is no key mechanism on the gas sampling bulbs. These are intended for use at atmospheric pressure. The maximum psi has not been established. The way to keep from breaking the glass is to not overfill the apparatus.
      Directions for filling a Gas Sampling Bulb and Making a Standard:

      I. Flush the bulb with clean helium or nitrogen before collecting the sample.

      a. Open both stopcocks and flow at least on 1 1/2 to 2 bulb volumes.
      b. Close the outlet stopcock, then the inlet stop cock after turning the gas supply off.
      c. If pressure cannot be controlled then try the following:
      i. Attach a 1-2 foot piece of tubing to the outlet of the sampling bulb.
      ii. Close the inlet stopcock, then very quickly close the outlet stop cock (the tubing on the outlet will help prevent diffusion of the outside air entering the sampling bulb.
      1. Sample will be very close to atmospheric pressure after turning the gas supply off.
      iii. Inject a known quantity of compound
      iv. If necessary, heat the bulb in an oven to vaporize the compounds injected.

      도움이 되었습니까?