If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf
추천 제품
사용
sufficient for 2,500 colorimetric tests
검출 방법
colorimetric
관련 질환(들)
cardiovascular diseases; gastrointestinal diseases
저장 온도
2-8°C
일반 설명
애플리케이션
- Phosphatase Assays: liberation of phosphate from peptide, protein, or small molecule substrate.[1][3]
- Lipase Assays: liberation of phosphate from phospholipids
- Nucleoside Triphosphatase Assays: liberation of phosphate from nucleoside triphosphates (ATP, GTP, TTP, CTP etc).
- Quantitation of phosphate in phospholipids, proteins and DNAs, etc.
- Drug Discovery: high-throughput screen for phosphatase inhibitors.
특징 및 장점
적합성
원리
신호어
Warning
유해 및 위험 성명서
Hazard Classifications
Eye Irrit. 2 - Flam. Liq. 3 - Met. Corr. 1 - Skin Irrit. 2
Storage Class Code
3 - Flammable liquids
Flash Point (°F)
82.4 °F
Flash Point (°C)
28 °C
가장 최신 버전 중 하나를 선택하세요:
시험 성적서(COA)
-
How can I determine the shelf life / expiration / retest date of this product?
1 답변-
도움이 되었습니까?
-
-
Is this kit able to detect pyrophosphate too?
1 답변-
This kit is intended for the detection of free orthophosphate and has not been tested for pyrophosphate detection. There are other products available that are specifically for use in pyrophosphate detection. Please see the links below to review each item:
MAK168, Pyrophosphate Assay Kit
https://www.sigmaaldrich.com/product/sigma/mak168
MAK169. High Sensitivity Pyrophosphate Assay Kit
https://www.sigmaaldrich.com/product/sigma/mak169도움이 되었습니까?
-
-
Does the product MAK307 contain magnesium?
1 답변-
Magnesium is not included as a component in any of the reagents provided with the kit for product MAK307. If magnesium serves as an essential cofactor for the enzyme, it is recommended to supplement it in the buffer before conducting the phosphate determination assay.
도움이 되었습니까?
-
-
What are the reasons behind the suggestion to use lower concentrations than 0.25mM? Are there potential unwanted biochemical reactions between GTP and malachite green/molybdate if GTP concentration exceeds 0.25mM?
1 답변-
The kit operates by releasing free orthophosphate from ATP or GTP, followed by the creation of a green complex involving the orthophosphate, molybdate, and Malachite green. It has been observed that samples containing ATP and GTP at concentrations exceeding 0.25mM result in the measurement of free phosphate levels falling outside the detection range of the kit (0.02 µM and 40 µM phosphate), and hence should be avoided.
도움이 되었습니까?
-
-
Why is it necessary to dilute the ATP concentration to <0.25 mM before the assay? Does ATP interfere with the assay?
1 답변-
BioAssay Support recommends reducing the ATP concentration before the assay to minimize background interference resulting from non-enzymatic ATP hydrolysis and to decrease the likelihood of reagent precipitation with unhydrolyzed ATP.
도움이 되었습니까?
-
-
our kit expired, when I used to measure extracted polyphosphate degraded by the enzyme, the results were so different compared to the precious ones (when the kit was not expired), this means the result was not reliable after it expired?
1 답변-
Correct, products used beyond the expiration date will likely offer poor results.
도움이 되었습니까?
-
-
Does Malachite Green interact with glycerol?
1 답변-
The Malachite Green Phosphate Assay Kit is based on the quantification of the green complex formed between Malachite Green, molybdate, and free orthophosphate. No specific compatibility study has been done with this kit and glycerol. This would need to be tested empirically, in a sample with a known phosphate concentration, with and without glycerol at the desired concentration.
도움이 되었습니까?
-
-
Can we test the same MG in shrimp matrix ?
1 답변-
This product is suitable for a variety of sample types. There is no reason to suspect a problem with shrimp matrix. Attention should be given to sample preparation, handling, and dilution. See the link below to review the product datasheet which includes the protocol and troubleshooting tips:
https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/171/212/mak307bul.pdf도움이 되었습니까?
-
-
How is shipping temperature determined? And how is it related to the product storage temperature?
0 답변
활성 필터
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.