콘텐츠로 건너뛰기
Merck
모든 사진(3)

주요 문서

MAK052

Sigma-Aldrich

ALT Activity Assay

sufficient for 100 colorimetric or fluorometric tests

동의어(들):

Alanine Aminotransferase Activity Assay Kit, SGPT Activity Assay Kit, Serum Glutamic-Pyruvic Transaminase Activity Assay Kit

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
12161503
NACRES:
NA.84
가격 및 재고 정보를 현재 이용할 수 없음

사용

sufficient for 100 colorimetric or fluorometric tests

검출 방법

colorimetric
fluorometric

관련 질환(들)

gastrointestinal diseases

배송 상태

wet ice

저장 온도

−20°C

유전자 정보

human ... GPT(2875)
mouse ... GPT(76282)
rat ... GPT(81670)

일반 설명

Alanine Aminotransferase (ALT), also known as serum glutamic-pyruvic transaminase (SGPT), is a pyridoxal-phosphate-dependent enzyme that catalyzes the reversible transfer of an amino group from alanine to α-ketoglutarate, generating pyruvate and glutamate. ALT is found primarily in liver and serum, but occurs in other tissues as well. Hepatocellular injury often results in an increase of serum ALT levels and serum ALT levels can be used as a marker for liver injury.

애플리케이션

ALT Activity Assay kit has been used to determine the activity of alanine aminotransferase (ALT) in serum samples.[1][2][3]

특징 및 장점

Compatible with high-throughput handling systems.

적합성

Suitable for the measurement of alanine aminotransferase (ALT) activity in biological samples including tissue, cells and serum.

원리

The ALT Activity Assay Kit provides a simple and direct procedure for measuring ALT activity in a variety of biological samples.

ALT activity is determined by a coupled enzyme assay, which results in a colorimetric (570 nm)/ fluorometric (λex = 535/λem = 587 nm) product, proportional to the pyruvate generated. One unit of ALT is defined as the amount of enzyme that generates 1.0 μmole of pyruvate per minute at 37 °C.

관련 제품

제품 번호
설명
가격

픽토그램

Health hazard

신호어

Danger

유해 및 위험 성명서

Hazard Classifications

Aquatic Chronic 3 - Resp. Sens. 1 - Skin Sens. 1

Storage Class Code

10 - Combustible liquids

WGK

WGK 3


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

L Bočkor et al.
Gene therapy, 24(10), 649-660 (2017-08-15)
Adeno-associated virus (AAV) -mediated gene therapy is a promising strategy to treat liver-based monogenic diseases. However, two major obstacles limit its success: first, vector dilution in actively dividing cells, such as hepatocytes in neonates/children, due to the non-integrating nature of
Resolvin D1 and E1 alleviate the progress of hepatitis toward liver cancer in long-term concanavalin A-induced mice through inhibition of NF-KB activity.
Kuang H, et al.
Oncology Reports, 35(1), 307-317 (2016)
Investigation of Therapeutic Effects of $\alpha$-Mangostin on Thioacetamide-Induced Cirrhosis in Rats
Nilbunga S.
Journal of the Medical Association of Thailand = Chotmaihet Thangphaet, 98(9), S91-S97 (2015)
Brett Palaschak et al.
Molecular therapy. Methods & clinical development, 5, 142-152 (2017-05-10)
Multiple independent adeno-associated virus (AAV) gene therapy clinical trials for hemophilia B, utilizing different AAV serotypes, have reported a vector dose-dependent loss of circulating factor IX (FIX) protein associated with capsid-specific CD8
Pratiksha I Thakore et al.
Nature communications, 9(1), 1674-1674 (2018-04-28)
CRISPR-Cas9 transcriptional repressors have emerged as robust tools for disrupting gene regulation in vitro but have not yet been adapted for systemic delivery in adult animal models. Here we describe a Staphylococcus aureus Cas9-based repressor (dSaCas9KRAB) compatible with adeno-associated viral

질문

1–8 / 8 질문  
  1. Hi, Does this ALT kit depend on LDH for the ultimate readout? Our goal is to measure liver dysfunction in serum of mice. Would differences in serum LDH influence the results? Thanks Ricky

    1 답변
    1. This kit does not use lactate dehydrogenase (LDH) itself, but the measured results are proportional to the concentration of pyruvate generated. Because LDH (in the presence of NADH) can influence the concentration of pyruvate present, the presence of LDH in a sample may influence the assay results.

      LDH was not assessed in the development of this kit, but the kit has been used to test serum samples directly. It is recommended to perform several sample dilutions to determine the optimal sample concentration and ensure measured values fall within the linear range of the standard curve. Liver cell and liver-derived cell line lysates are more commonly measured, as serum levels of ALT are normally low. Regardless, considering the effect of LDH on pyruvate in the presence of NADH, a variable concentration of LDH and/or NADH may impact the ALT assay results.

      도움이 되었습니까?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 답변
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      도움이 되었습니까?

  3. How can I determine the shelf life / expiration / retest date of this product?

    1 답변
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      도움이 되었습니까?

  4. Can I know the specific activity of this ALT mix sample? In unit of U/mg

    1 답변
    1. The ALT Enzyme Mix included in this kit is a lyophilized mixture of enzymes. The components include Pyruvate Oxidase, Cocarboxylase, and Sucrose. The concentration and activity of each enzyme are considered proprietary. Please see the link below to review the product datasheet:
      https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/731/802/mak052bul.pdf

      도움이 되었습니까?

  5. How does the presence of pyruvate in the Krebs buffer affect the final reaction of the kit, and why is its removal recommended? Additionally, what is the significance of the absence of enzymes in the kit for converting glucose and lactate to pyruvate in relation to the buffer?

    1 답변
    1. The kit's final reaction is dependent on the oxidation of pyruvate, so its presence in the buffer may interfere with the assay. If possible, it is recommended to remove pyruvate from the Krebs buffer. However, the kit does not contain enzymes that can convert glucose to pyruvate or lactate to pyruvate, so the presence of these should not pose an issue in the buffer.

      도움이 되었습니까?

  6. Is the ALT activity assay kit MAK052 compatible with EDTA plasma? Does EDTA interfere with the activity of the assay?

    1 답변
    1. EDTA has the potential to deactivate the enzyme. ​Therefore, it is recommended not to use samples containing EDTA for performing the AST and ALT assay kits, including the MAK055 kit.

      도움이 되었습니까?

  7. Can I use the kit for both mouse and human serum?

    1 답변
    1. This kit is suitable for mouse and human serum. As mentioned on the Product Detail Page, this item is suitable for measuring alanine aminotransferase (ALT) activity in biological samples including tissue, cells, and serum.

      도움이 되었습니까?

  8. Can it be used for measuring on supernatant from liver cells

    1 답변
    1. The kit is optimized for use in determination of alanine aminotransferase in biological samples (e.g. plasma, serum, cell lysate, tissue samples.) This kit has not been tested for use with cell culture supernatant. The presence of phenol red may interfere with results. In addition, the cultured cell line may not secrete sufficient ALT to be detected. It would be up to the end user to determine suitability.

      도움이 되었습니까?

후기

평점 값 없음

활성 필터

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.