콘텐츠로 건너뛰기
Merck
모든 사진(1)

주요 문서

GE29-1081-07

illustra Single Cell GenomiPhi DNA Amplification Kit

Cytiva 29-1081-07, sufficient for 25 reactions sufficient, storage temp.:-70°C

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
41106100
가격 및 재고 정보를 현재 이용할 수 없음 고객지원팀으로 연락바랍니다.

사용

sufficient for 25 reactions sufficient

제조업체/상표

Cytiva 29-1081-07

재고 정보

not available in Japan

저장 온도

−70°C

일반 설명

Genomic analysis from single cells is an emerging area as researchers focus in on differences within cell populations. The amount of genomic DNA needed to carry out a full range of testing has impacted progress, and while techniques become more sensitive, sharing a single cell′s DNA across platforms is not possible.

At very low levels of input DNA, successful amplification relies on reagent quality. Single Cell GenomiPhi has been developed with this in mind. Lysis reagents are optimized to fully release genomic DNA from the cell and subsequently denature the DNA to enable optimal amplification and coverage. Background amplification, often associated with Multiple Displacement Amplification (MDA), is suppressed throughout the incubation so that only input DNA is amplified.

High quality reagents and an optional, proprietary enzymatic clean-up step in the protocol ensure that any potential DNA contaminants introduced during set-up are removed before each individual reaction. In addition, our manufacturing processes, including UV and enzymatic reagent cleanup, help to ensure that all kits are free from any detectable DNA contamination and enable sensitivity of amplification down to fg of gDNA.

High quality reagents and an optional, proprietary enzymatic clean-up step in the protocol ensure that any potential DNA contaminants introduced during set-up are removed before each individual reaction. In addition, our manufacturing processes, including UV and enzymatic reagent cleanup, help to ensure that all kits are free from any detectable DNA contamination and enable sensitivity of amplification down to 1 fg of gDNA.

애플리케이션

Single Cell GenomiPhi offers a simple two-step workflow for whole genome amplification. The amplification process is 2 to 4 hours depending on the amount of starting DNA and yields of 4 to 7 μg can be achieved.

Amplification is highly uniform over the entire genome so that locus representation remains extremely close to the original DNA sample. Furthermore, amplification is carried out with very high fidelity due to Phi29 DNA polymerase proofreading activity. DNA from single cells can be reproducibly and reliably amplified for use in many downstream applications. Single Cell GenomiPhi has been successfully used to generate template for SNP array genotyping, array CGH, and next-generation sequencing.

특징 및 장점

Single Cell Genomiphi DNA Amplification kit combines the unique capabilities of Phi29 DNA polymerase with an optimized formulation to amplify genomic DNA from 1-1000 cells without background interference.



  • Whole Genome Amplification of genomic DNA from as little as a single cell.
  • Novel clean-up process supresses background allowing sensitivity down to 1 fg of input DNA.
  • Simple isothernal strand displacement (MDA) technology using Phi29 DNA polymerase.
  • Amplifications can be completed in less than 3 hours with less than 15 minutes hands on time.
  • Optimized to promote complete cell lysis with uniform denaturation of DNA prior to amplification.

분석 메모

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

법적 정보

GenomiPhi
On packaging and insert:
For use only as licensed by Qiagen GmbH. and Cytiva. The Phi 29 DNA polymerase may not be re-sold or used except in conjunction with the other components of this kit. See US patent numbers 5,854,033, 6,124,120, 6,143,495, 6,323,009, 5,576,204, and equivalent patents and patent applications in other countries.
On container:
Subject to proprietary rights of Cytiva. May not be re-sold or used except with the other components of this kit. See US patent numbers 5,576,204, and equivalent patents and patent applications in other countries.
GenomiPhi is a trademark of Cytiva
illustra is a trademark of Cytiva

가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 문서 section.

도움이 필요하시면 연락하세요. 고객 지원 부서

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.