D9777

Sigma-Aldrich

Dialysis tubing cellulose membrane

avg. flat width 25 mm (1.0 in.)

동의어(들):

Cellulose dialysis tubing, Dialysis membrane

로그인조직 및 계약 가격 보기

크기 선택

100 FT
₩333,631

₩333,631


예상 입고일2025년 4월 17일세부사항



크기 선택

보기 변경
100 FT
₩333,631

About This Item

UNSPSC 코드:
41123100
NACRES:
NB.22

₩333,631


예상 입고일2025년 4월 17일세부사항


평균 직경

16 mm , when full

평균 평폭

25 mm (1.0 in.)

용량

~60 mL/ft

유사한 제품을 찾으십니까? 방문 제품 비교 안내

관련 카테고리

일반 설명

Typical molecular weight cut-off = 14,000.

포장

Supplied in rolls, dry

품질

May contain glycerin and sulfur compounds in more than trace amounts.

제조 메모

Removal of glycerol included as a humectant can be accomplished by washing the tubing in running water for 3-4 hours. Removal of sulfur compounds can be accomplished by treating the tubing with a 0.3% (w/v) solution of sodium sulfide at 80°C for 1 minute. Wash with hot water (60°C) for 2 minutes, followed by acidification with a 0.2% (v/v) solution of sulfuric acid, then rinse with hot water to remove the acid. This tubing will retain most proteins of molecular weight 12,000 or greater.

가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Maryam Tabassum Hussain et al.
International journal of pharmaceutics, 590, 119955-119955 (2020-10-10)
The addition of polyethylene glycol (PEG) on the surface of liposomes increases their circulation time when administered intravenously. However, the inclusion of PEG using PEGylated phospholipids could result in a possible micelles formation. The development of chimeric systems mixing synthetic
Urszula Gawlik-Dziki et al.
Molecules (Basel, Switzerland), 25(21) (2020-11-05)
Stratiotes aloides L. is common water plant in central Poland. Due to its expansive character, S. aloides L. can strongly affect the functioning of aquatic ecosystems. S. aloides L. was an important famine plant in central Poland. This plant was
E Benediktsdóttir et al.
Letters in applied microbiology, 70(4), 282-289 (2020-01-03)
Outbreaks of viral gastroenteritis are often connected to contaminated drinking water. The assessment of the water quality relies on the cultivation of indicator bacteria, and little is known of the fate of viruses in groundwater, especially in arctic regions. In
Vatanparast Mohammad et al.
Journal of invertebrate pathology, 169, 107309-107309 (2019-12-21)
Phospholipase A2 (PLA2) hydrolyzes the ester bond of phospholipids (PLs) at sn-2 and releases free fatty acids and lysophospholipids that are subsequently changed into various signal molecules to mediate various physiological processes. Numerous PLA2s are known in various biological systems
Ivars Petrovskis et al.
Microorganisms, 9(2) (2021-02-13)
The core proteins (HBc) of the hepatitis B virus (HBV) genotypes A, B, C, D, E, F, and G were cloned and expressed in Escherichia coli (E. coli), and HBc-formed virus-like particles (VLPs) were purified with ammonium sulfate precipitation, gel

관련 콘텐츠

Dialysis Tubing

질문

1–5 / 5 질문  
  1. Is this product ready to use?Do I need to boil it or place it into NaHCO3 before I use dialysis tube?

    1 답변
    1. Most applications will require pre-treatment prior to dialysis. As mentioned in the 'DESCRIPTION' section, under 'Preparation Note', for the removal of glycerol included as a humectant, wash the tubing in running water for 3-4 hours. To remove any residual sulfur, treat the tubing with a 0.3% (w/v) solution of sodium sulfide at 80°C for 1 minute. Wash with hot water (60°C) for 2 minutes, followed by acidification with a 0.2% (v/v) solution of sulfuric acid, then rinse with hot water to remove the acid. Wetted membranes may be stored in water containing benzoic acid or formaldehyde.

      도움이 되었습니까?

  2. can it seprate 5 nm gold particle from gold solution

    1 답변
    1. If the particle is larger than the tubing's 14 kDa molecular weight cut-off (MWCO) rating, it should be retained.

      도움이 되었습니까?

  3. what is the storage temperature of this membrane

    1 답변
    1. This product may be stored at room temperature. For products with no specified storage temperature given on the label or product page, ambient storage may be assumed. Products that require controlled temperature storage, such as refrigeration or freezer conditions, storage temperatures are published on the product label, Certificate of Analysis, and the Safety Data Sheet (SDS).

      도움이 되었습니까?

  4. Hello, I would like to ask what is the pore size (in nanometres) of the dialysis membrane? (SKU code: D9777 ,Dialysis tubing cellulose membrane, avg. flat width 25 mm (1.0 in.))

    1 답변
    1. The pore size is not determined for this product.

      도움이 되었습니까?

  5. What are the molecular weight cut-off and the pores size of this dialysis tubing cellulose membrane?

    1 답변
    1. As mentioned on the product detail page, the typical molecular weight cut-off is 14,000. However, this tubing will retain most proteins of molecular weight 12,000 or greater. The pore size has not been determined.

      도움이 되었습니까?

후기

평점 값 없음

활성 필터

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.