추천 제품
형태
liquid
농도
≥1 mg/mL (active substance)
형광
λex 566 nm; λem 576 nm in 0.1 M phosphate pH 7.0
저장 온도
2-8°C
일반 설명
Streptavidin-R-Phycoerythrin is a fluorescent labeling agent comprised of a biotin-binding protein (streptavidin) covalently attached to a fluorescent label ((R-phycoerythrin). Streptavidin-R-phycoerythrin complexes provide the measurement method for the target phosphoprotein. And, Streptavidin R-phycoerythrin extends the light tolerance of certain phycobiliproteins.
애플리케이션
Streptavidin-R-Phycoerythrin (R-PE) is used to label biotin-conjugated (biotinylated) molecules and biotin derivatized surfaces in a wide variety of immunofluorescence applications such as immunochemistry and histochemistry. Streptavidin-R-Phycoerythrin may be used in the development of bioassay devices such as Lab-on-a-chip (LoC) systems and microarrays.
법적 정보
Geniom is a registered trademark of Febit Biotech GmbH
Storage Class Code
12 - Non Combustible Liquids
WGK
WGK 1
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
이미 열람한 고객
Malaria journal, 19(1), 188-188 (2020-05-26)
While sub-microscopic malarial infections are frequent and potentially deleterious during pregnancy, routine molecular detection is still not feasible. This study aimed to assess the performance of a Histidine Rich Protein 2 (HRP2)-based ultrasensitive rapid diagnostic test (uRDT, Alere Malaria Ag
Biomedical microdevices, 13(5), 819-827 (2011-05-24)
Point-of-care (PoC) testing followed by personalized efficient therapy of infectious diseases may result in a considerable reduction of associated health care costs. Lab-on-a-chip (LoC) systems represent a potentially high efficient class of PoC tools. Here, we present a LoC system
Steroids, 75(13-14), 1089-1096 (2010-07-27)
The small blood volumes available in rodent studies often limit adequate quantification of all hormones of interest. We report here the development of two new assays combining an extraction step with multiplex immunoassay (MIA) technology for the simultaneous determination of
Clinical chemistry, 52(6), 1033-1039 (2006-03-25)
Genotyping of N-acetyltransferase-2 (NAT2) is useful in predicting the risk for toxicity of NAT2 substrates. Current methods cannot detect the 7 most important single-nucleotide variations in NAT2 simultaneously in 1 tube. We developed an assay that uses allele-specific primer extension
Vaccine, 39(4), 687-698 (2020-12-29)
The evaluation of immune responses to RTS,S/AS01 has traditionally focused on immunoglobulin (Ig) G antibodies that are only moderately associated with protection. The role of other antibody isotypes that could also contribute to vaccine efficacy remains unclear. Here we investigated
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..