KHGEG015FB3
Millipore Express® SHC, Opticap® XL Capsule
Opticap® XL 150, inlet connection diam. 3/4 in., pore size 0.5/0.2 μm, cartridge nominal length 3.8 in. (9.7 cm)
동의어(들):
Opticap Gamma Compatible XL 150 Millipore Express SHC 0.5/0.2 m 3/4 in. TC-9/16 in. HB with Bell
About This Item
추천 제품
material
polyethersulfone
polyethylene support
polypropylene (gamma-stable)
polypropylene housing
polypropylene vent cap (Gamma stable)
polysulfone
silicone seal
Quality Level
규정 준수
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
설명
19 mm (3/4 in.) Sanitary Flange Inlet and 14 mm (9/16 in.) Hose Barb Outlet with filling bell
무균
non-sterile
멸균 적합성
gamma compatible
제품 라인
Opticap® XL 150
특징
hydrophilic
제조업체/상표
Millipore Express®
파라미터
≤1.0 mL/min air diffusion at 2.8 bar (40 psig) and 23 °C (in water)
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
100 psi max. differential pressure (6.9 bar) (intermittent)
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 23 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 23 °C (intermittent)
80 psi max. differential pressure (5.5 bar) (continuous)
80 psig max. inlet pressure
기술
sterile filtration: suitable
길이
9.7 cm (3.8 in.)
너비
2.2 in.
카트리지 공칭 길이
3.8 in. (9.7 cm)
직경
5.6 cm (2.2 in.)
여과 면적
140 cm2
입구 연결 직경
3/4 in.
입구에서 출구 너비(W)
9.7 cm (3.8 in.)
출구 연결 직경
9/16 in.
불순물
≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
Matrix
Millipore Express® SHC
pore size
0.5/0.2 μm pore size
버블 포인트(bubble point)
≥4000 mbar (58 psig), air with water at 23 °C
피팅
1/4 in. drain/vent hose barb (with double O-ring seal)
inlet sanitary flange
outlet hose barb (with Bell)
일반 설명
포장
기타 정보
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
제조 메모
Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
분석 메모
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
After sterilization and a controlled water flush of 1.0 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
법적 정보
면책조항
Emprove® 프로그램이란?
Emprove® 프로그램은 자사의 필터 그리고 일회용 구성품, 제약용 원료 물질 및 시작 물질의 종합적이고 빈틈없는 문건을 제공하는 체계입니다.
무료 - 다운로드하려면 로그인하십시오
무료 - 다운로드하려면 로그인하십시오
구독하거나 수수료를 지급하시면 이용 가능
구독하거나 수수료를 지급하시면 이용 가능
활성 필터
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.