HKI2MAG-99K
MILLIPLEX® Human Kidney Injury Magnetic Bead Panel 2 - Toxicity Multiplex Assay
The analytes available for this multiplex kit are: α-1-Microglobulin, Albumin, Clusterin, Cystatin C, EGF, Lipocalin-2/NGAL, and Osteopontin (OPN).
동의어(들):
Human Kidney Toxicity Multiplex Assay, Luminex® Human Kidney Toxicity Assay, Millipore Human Kidney Toxicity Panel
About This Item
추천 제품
Quality Level
종 반응성
human
제조업체/상표
Milliplex®
assay range
accuracy: 95-109%
sensitivity: 0.015-5.359 ng/mL
(MinDC = 2SD)
standard curve range: 0.01-10 ng/mL
(EGF)
standard curve range: 0.02-20 ng/mL
(Lipocalin-2/ NGAL)
standard curve range: 0.20-200 ng/mL
(Cystatin C)
standard curve range: 0.59-600 ng/mL
(Osteopontin (OPN))
standard curve range: 0.98-1,000 ng/mL
(α-1-Microglobulin)
standard curve range: 3.91-4,000 ng/mL
(Albumin)
standard curve range: 4.88-5,000 ng/mL
(Clusterin)
inter-assay cv: <20%
intra-assay cv: <10%
기술
multiplexing: suitable
검출 방법
fluorometric (Luminex xMAP)
배송 상태
wet ice
일반 설명
The MILLIPLEX® portfolio provides valuable research assays to investigate multiple biomarkers of kidney injury in human urine samples using the Luminex® xMAP® instrument platform. The analytes available for this multiplex kit are: α-1-Microglobulin, Albumin, Clusterin, Cystatin C, EGF, Lipocalin-2/NGAL, and Osteopontin (OPN).
Panel Type: Toxicity
특이성
There was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes within a panel.
애플리케이션
- Analytes: α-1-Microglobulin, Albumin, Clusterin, Cystatin C, EGF, Lipocalin-2/NGAL, Osteopontin (OPN)
- Recommended Sample type: Urine
- Recommended Sample dilution: 1:100 in kit Assay Buffer. Customers need to determine the optimal dilution factor for their samples. Our recommendations are based on urine samples from normal subjects.
- Assay Run Time: Overnight
- Research Category: Toxicity
특징 및 장점
기타 정보
법적 정보
면책조항
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2
표적 기관
Respiratory Tract
Storage Class Code
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
관련 콘텐츠
Multiplex kidney toxicity assays detect nephrotoxicity biomarkers in small samples, minimizing time and costs for toxicity screening.
MILLIPLEX® toxicity assays advance liver, kidney, and genotoxicity research by simultaneously measuring multiple toxicity biomarkers.
Discover the benefits of MILLIPLEX® multiplex assays, based on Luminex® xMAP® multiplex assay technology, that provide consistent, high-quality results and see how these multiplex biomarker Luminex® assays are being used to advance research.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.