추천 제품
제품명
LiChrosorb® RP-18 (10 µm),
material
stainless steel column
Agency
suitable for USP L1
제품 라인
LiChrosorb®
특징
endcapped: no
파라미터
60 °C max. temp.
기술
HPLC: suitable
mass spectrometry (MS): suitable (Low)
Matrix
fully porous particle
기질 활성군
C18 bonding phase
입자 크기
10 μm
공극 크기
100 Å pore size
작동 pH 범위
2-7.5
벌크 밀도
200‑400 kg/m3
분리 기술
reversed phase
저장 온도
no temp limit
애플리케이션
- High-performance liquid chromatographic determination of the antifungal drug fluconazole in plasma and saliva of human immunodeficiency virus-infected patients.: This study highlights a method using RP-18 for the determination of fluconazole, demonstrating the column′s effectiveness in bioanalytical contexts (Beijnen JH et al., 1995).
- Determination of serum aluminium using an ion-pair reversed-phase high-performance liquid chromatographic-fluorimetric system with lumogallion.: This research utilizes RP-18 to analyze serum aluminum, showcasing its utility in trace metal analysis in clinical samples (Ong CN et al., 1995).
- A radiochemical high-performance liquid chromatographic method for the analysis of 2-fluoro-2-deoxy-D-glucose-derived metabolites in human chondrocytes.: The method developed employs RP-18, underscoring its role in the radiochemical analysis of complex biological matrices (Greiling H et al., 1993).
- Systematic approach to the determination of cephalosporins in biological fluids by reversed-phase liquid chromatography.: This study demonstrates the application of RP-18 in the pharmacokinetic analysis of cephalosporins, further proving the column′s broad applicability in pharmaceutical analyses (Juge F et al., 1983).
- Simultaneous determination of 3,4-dihydroxyphenylalanine, 5-hydroxytryptophan, dopamine, 4-hydroxy-3-methoxyphenylalanine, norepinephrine, 3,4-dihydroxyphenylacetic acid, homovanillic acid, serotonin, and 5-hydroxyindoleacetic acid in rat cerebrospinal fluid and brain by high-performance liquid chromatography with electrochemical detection.: This research uses RP-18 to simultaneously quantify multiple neurotransmitters, highlighting its sensitivity and specificity for neurochemical analysis (Huot S et al., 1982).
분석 메모
stability testing (performance): passes test
particle size (Malvern) (d10): 8.7 - 10.0 µm
particle size (Malvern) (d50): 12.0 - 14.0 µm
particle size (Malvern) (d90): 17.5 - 20.5 µm
법적 정보
Storage Class Code
11 - Combustible Solids
WGK
nwg
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
활성 필터
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.