추천 제품
Grade
certified reference material
형태
liquid
특징
(Snap-N-Spike®)
포장
ampule of 1 mL
제조업체/상표
Cerilliant®
농도
100 μg/mL in methanol
기술
gas chromatography (GC): suitable
liquid chromatography (LC): suitable
응용 분야
clinical testing
clinical testing
형식
single component solution
저장 온도
−20°C
InChI
1S/C21H32O3/c1-13(22)21(24)11-8-18-16-5-4-14-12-15(23)6-9-19(14,2)17(16)7-10-20(18,21)3/h4,15-18,23-24H,5-12H2,1-3H3/t15-,16+,17-,18-,19-,20-,21-/m0/s1
InChI key
JERGUCIJOXJXHF-TVWVXWENSA-N
일반 설명
17α-Hydroxypregnenolone is a steroid hormone produced in the adrenal glands. This hormone is monitored as an ancillary test for congenital adrenal hyperplasia (CAH), particularly in situations where diagnosis of 21-hydroxylase and 11-hydroxylase eficiency has been ruled out. This Certified Spiking Solution® is suitable for use as starting material in linearity standards, calibrators, and controls fo numerous LC-MS/MS applications in endocrinology, clinical chemistry, and neonatal screening.
애플리케이션
- Enhancement of Steroidogenic Enzyme Assays: The role of protein-protein and protein-membrane interactions in cytochrome P450 function, which is crucial for understanding the enzymatic activities involved in steroid biosynthesis, including those mediated by 17 alpha-Hydroxypregnenolone (Scott EE et al., 2016).
- Modeling Steroid Hormone Biosynthesis: Research explores how ligand and cytochrome b5 modulate the conformation of human cytochrome P450 17A1, a key enzyme in the biosynthesis of neurosteroids from precursors like 17 alpha-Hydroxypregnenolone, providing insights for biochemical steroidogenesis research (Estrada DF et al., 2014).
- Development of ELISA for Steroid Detection: The study demonstrate the covalent coupling of steroids to microwell plates, facilitating the use of 17 alpha-Hydroxypregnenolone in competitive enzyme-linked immunosorbent assays (ELISA) for steroid hormone precursor detection and quantification in biochemical assays (Yonezawa S et al., 1993).
법적 정보
CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
CERTIFIED SPIKING SOLUTION is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany
신호어
Danger
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1
표적 기관
Eyes
Storage Class Code
3 - Flammable liquids
WGK
WGK 1
Flash Point (°F)
49.5 °F - closed cup
Flash Point (°C)
9.7 °C - closed cup
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
이미 열람한 고객
[17alpha-hydroxypregnenolone].
Nihon rinsho. Japanese journal of clinical medicine, 63 Suppl 8, 340-343 (2005-09-10)
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.