콘텐츠로 건너뛰기
Merck
모든 사진(1)

주요 문서

719900

Sigma-Aldrich

Resomer® RG 504 H, Poly(D,L-lactide-co-glycolide)

acid terminated, lactide:glycolide 50:50, Mw 38,000-54,000

동의어(들):

PLGA

로그인조직 및 계약 가격 보기

크기 선택

1 G
₩115,101
5 G
₩506,688

₩115,101


구입 가능 여부는 고객센터에 문의하십시오.

벌크 견적 요청

크기 선택

보기 변경
1 G
₩115,101
5 G
₩506,688

About This Item

Linear Formula:
[C3H4O2]x[C2H2O2]y
CAS Number:
MDL number:
UNSPSC 코드:
12162002
NACRES:
NA.23

₩115,101


구입 가능 여부는 고객센터에 문의하십시오.

벌크 견적 요청

Quality Level

양식

amorphous

피드(feed) 비율

lactide:glycolide 50:50

분자량

Mw 38,000-54,000

분해 기간

<3 months

점도

0.45-0.60 dL/g, 0.1 % (w/v) in chloroform(25 °C, Ubbelohde) (size 0c glass capillary viscometer)

전이 온도

Tg 46-50 °C

저장 온도

2-8°C

SMILES string

O2C(C(=O)OC(C2=O)C)C.O1CC(=O)OCC1=O

InChI

1S/C6H8O4.C4H4O4/c1-3-5(7)10-4(2)6(8)9-3;5-3-1-7-4(6)2-8-3/h3-4H,1-2H3;1-2H2

InChI key

LCSKNASZPVZHEG-UHFFFAOYSA-N

애플리케이션

Resomer® RG 504 H, Poly(D, L-Lactide-co-Glycolide) can be used to fabricate a biodegradable hemostyptic device for safe and locally controlled release of thrombin which promotes local blood clot formation.

It can be used to preparepolymer nanospheres for encapsulating CuO, to form stimuli-responsivemultifunctional nanocarriers.

법적 정보

Product of Evonik
RESOMER is a registered trademark of Evonik Rohm GmbH

Storage Class Code

11 - Combustible Solids

WGK

WGK 3

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Niranjan G Kotla et al.
Nanomaterials (Basel, Switzerland), 9(9) (2019-09-05)
There is a pressing clinical need for advanced colon-specific local drug delivery systems that can provide major advantages in treating diseases associated with the colon, such as inflammatory bowel disease (IBD) and colon cancer. A precise colon targeted drug delivery
Hossein Kamali et al.
Materials science & engineering. C, Materials for biological applications, 96, 561-575 (2019-01-05)
An in situ forming gel (ISFG) of buprenorphine (BP) was prepared using PLGA-PEG-PLGA (triblock) and N‑methyl‑2‑pyrrolidone as solvent for decreasing the initial burst release. Supercritical CO2 method was used for ring opening polymerization of triblock. The optimum formulation of ISFG
Teresa Musumeci et al.
International journal of pharmaceutics, 440(2), 135-140 (2012-10-20)
Melatonin, a neurohormone secreted by the pineal gland, is able to modulate intraocular pressure (IOP). The aim of this study was to generate nanoparticle (NPs) sustained release formulations that allow to extend the pre-corneal residence time of melatonin, thus prolonging
Igor Jeroukhimov et al.
Journal of the American College of Surgeons, 218(1), 102-107 (2013-11-12)
Chronic pain after inguinal hernia repair occurs in 16% to 62% of patients. The underlying mechanism probably involves sensory nerve damage and abnormal healing that might be influenced by the materials chosen for the procedure. We hypothesize that nonabsorbable sutures
Maria Kirzhner et al.
Ophthalmology, 120(6), 1300-1304 (2013-02-13)
To compare wrapped and polymer-coated hydroxyapatite implants in children undergoing primary enucleation with no adjuvant therapies. Retrospective, interventional cohort study. All children undergoing primary enucleation without adjuvant therapies between 1999 and 2009 at a tertiary pediatric cancer hospital. Review and

문서

Interest in utilizing biodegradable polymers for biomedical applications has grown since the 1960s.

Synthetic aliphatic polyesters dominate resorbable biomaterials in clinical use.

AliAliphatic polyesters, including polylactide and polyglycolide, are biodegradable polymers widely used in medical applications.

Immunosuppressive tumor-associated myeloid cells (TAMC) are responsible for glioblastoma (GBM) resistance to immunotherapies and existing standard of care treatments. This mini-review highlights recent progress in implementing nanotechnology in advancing TAMC-targeted therapies for GBM.

모두 보기

질문

1–4 / 4 질문  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 답변
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      도움이 되었습니까?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 답변
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      도움이 되었습니까?

  3. What is the degree of polydispersity of Resomer® RG 504 H, Poly(D,L-lactide-co-glycolide)?

    1 답변
    1. The degree of polydispersity for this product is calculated as the weight average molecular weight divided by the number average molecular weight (Mw/Mn). The specific value can be found on the Certificate of Analysis (COA) for each lot.

      도움이 되었습니까?

  4. Is the unit of the PLGA molecular weight of Resomer® RG 504 H, Poly(D, L-lactide-co-glycolide) Da?

    1 답변
    1. Yes, the molecular weight unit of this product is in Da or daltons.

      도움이 되었습니까?

후기

평점 값 없음

활성 필터

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.