vapor density
9.3 (vs air)
vapor pressure
<1 mmHg ( 20 °C)
분석
96%
양식
liquid
refractive index
n20/D 1.442 (lit.)
bp
150-159 °C/12 mmHg (lit.)
263-265 °C (lit.)
density
0.794 g/mL at 25 °C (lit.)
작용기
amine
SMILES string
CCCCCCN(CCCCCC)CCCCCC
InChI
1S/C18H39N/c1-4-7-10-13-16-19(17-14-11-8-5-2)18-15-12-9-6-3/h4-18H2,1-3H3
InChI key
DIAIBWNEUYXDNL-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
애플리케이션
Trihexylamine was used as extractant during isolation and purification of succinic acid from an Escherichia coli fermentation broth. It was employed as internal standard in screening of human hair specimens for designer drugs by ion mobility spectrometry. It was used in the synthesis of small diameter zinc oxide nanorods.
신호어
Warning
유해 및 위험 성명서
Hazard Classifications
Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3
표적 기관
Respiratory system
Storage Class Code
10 - Combustible liquids
WGK
WGK 3
Flash Point (°F)
235.4 °F - closed cup
Flash Point (°C)
113 °C - closed cup
개인 보호 장비
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
이미 열람한 고객
Biotechnology progress, 27(6), 1623-1628 (2012-01-13)
Biotechnologically produced succinic acid has the potential to displace maleic acid and its uses. Therefore, it is of high interest for the chemical, pharmaceutical, and food industry.In addition to optimized production strains and fermentation processes, an efficient separation of succinic
Forensic science international, 94(1-2), 55-63 (1998-07-22)
Since its inception in the early 1970s under the name plasma chromatography, ion mobility spectrometry (IMS) has undergone great changes. It is now utilized more and more in forensic science laboratories where it is used to detect explosives and environmental
Chemphyschem : a European journal of chemical physics and physical chemistry, 21(16), 1873-1881 (2020-03-17)
We outline two methodologies to selectively characterize the Brønsted acidity of the external surface of FAU-type zeolites by IR and NMR spectroscopy of adsorbed basic probe molecules. The challenge and goal are to develop reliable and quantitative IR and NMR
Diameter control and photoluminescence of ZnO nanorods from trialkylamines.
Journal of Nanomaterials, 2007 (2007)
Rapid communications in mass spectrometry : RCM, 34(5), e8608-e8608 (2019-11-11)
While liquid chromatography/high-resolution mass spectrometry (LC/HRMS) is a versatile analytical technique, it is also sensitive to trace impurities. These impurities may come from a variety of sources, including reagents, solvents, and the sample matrix itself. Impurities in reagents may become
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.