콘텐츠로 건너뛰기
Merck
모든 사진(3)

문서

441791

Sigma-Aldrich

Tris(2,4-di-tert-butylphenyl) phosphite

동의어(들):

2,4-Bis(1,1-dimethylethyl)phenol phosphite (3:1), Tri(2,4-di-tert -butylphenyl) phosphite, Tri(2,4-di-t -butylphenyl) phosphite

로그인조직 및 계약 가격 보기


About This Item

Linear Formula:
[[(CH3)3C]2C6H3O]3P
CAS Number:
Molecular Weight:
646.92
EC Number:
MDL number:
UNSPSC 코드:
12162002
PubChem Substance ID:
NACRES:
NA.23

mp

181-184 °C (lit.)

SMILES string

CC(C)(C)c1ccc(OP(Oc2ccc(cc2C(C)(C)C)C(C)(C)C)Oc3ccc(cc3C(C)(C)C)C(C)(C)C)c(c1)C(C)(C)C

InChI

1S/C42H63O3P/c1-37(2,3)28-19-22-34(31(25-28)40(10,11)12)43-46(44-35-23-20-29(38(4,5)6)26-32(35)41(13,14)15)45-36-24-21-30(39(7,8)9)27-33(36)42(16,17)18/h19-27H,1-18H3

InChI key

JKIJEFPNVSHHEI-UHFFFAOYSA-N

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

Tris(2,4-di-tert-butylphenyl) phosphite is a triaryl based phosphite that can be used in catalysis and metallation. Its characteristic to undergo metallation reaction and provide a cost effective synthetic processes allows it to be useful in biaryl coupling reactions.

애플리케이션

It may be used as a chain extender and a processing stabilizer that facilitate the production of stable polymeric materials, which include polylactic acid (PLA), polyolefins, etc.

Storage Class Code

13 - Non Combustible Solids

WGK

nwg

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable

개인 보호 장비

Eyeshields, Gloves, type N95 (US)


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Study of the high temperature reactions of a hindered aryl phosphite (Hostanox PAR 24) used as a processing stabiliser in polyolefins.
Kriston I, et al.
Polymer Degradation and Stability, 95(9), 1883-1893 (2010)
Orthopalladated triarylphosphite complexes as highly efficient catalysts in the Heck reaction.
Albisson DA
Tetrahedron Letters, 39(52), 9793-9796 (1998)
Orthopalladated triaryl phosphite complexes as highly active catalysts in biaryl coupling reactions.
Albisson DA, et al.
Chemical Communications (Cambridge, England), 19, 2095-2096 (1998)
Structure effect of phosphite on the chain extension in PLA.
Meng X, et al.
Polymer Degradation and Stability, 120(52), 283-289 (2015)
Ebru Oral et al.
Journal of orthopaedic research : official publication of the Orthopaedic Research Society, 32(6), 757-761 (2014-02-19)
Antioxidant stabilization of radiation cross-linked ultrahigh molecular weight polyethylene (UHMWPE) has been introduced to improve the oxidative stability of total joint implant bearing surfaces. Blending of an antioxidant with UHMWPE resin powder followed by consolidation and radiation cross-linking has been

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.