コンテンツへスキップ
Merck
  • Adsorbent phases with nanomaterials for in-tube solid-phase microextraction coupled on-line to liquid nanochromatography.

Adsorbent phases with nanomaterials for in-tube solid-phase microextraction coupled on-line to liquid nanochromatography.

Journal of chromatography. A (2016-01-23)
R A González-Fuenzalida, E López-García, Y Moliner-Martínez, P Campíns-Falcó
要旨

Following the present trends in miniaturization, a methodology that combines on-line In-Tube Solid-Phase Microextraction (IT-SPME) with Liquid Nanochromatography (nano-LC) and UV-vis diode array detection (DAD) was developed. This coupling was achieved by using two interconnected valves (i.e. conventional and micro-automatic valves) in the system of injection. As for IT-SPME, different materials, containing in some cases nanostructures or nanoparticles and in other cases polymeric adsorbent phases immobilized on capillary columns, were tested in order to improve extraction efficiencies of organic compounds; diclofenac was selected as the target analyte. Additionally, the transfer time of the sample between the two injection valves, as well as the lengths and the internal diameters of the capillary columns, was optimized. Under the selected conditions, the resulting IT-SPME-nano-LC-DAD method showed great potential to become a powerful analytical tool as it was successfully applied to the determination of diclofenac in pharmaceutical and water samples. For comparison purposes, IT-SPME coupled to Capillary Liquid Chromatography (Cap-LC) was used. The extraction yield of diclofenac reached near 80%, a high value for techniques that involve IT-SPME. Good accuracy (recoveries near 100%) and precision (4% RSD) were obtained.

材料
製品番号
ブランド
製品内容

Supelco
SPMEファイバーアセンブリー ジビニルベンゼン/カルボキセン/ポリジメチルシロキサン (DVB/CAR/PDMS), needle size 24 ga, StableFlex
Supelco
SPMEファイバーアセンブリー ジビニルベンゼン/カルボキセン/ポリジメチルシロキサン (DVB/CAR/PDMS), needle size 24 ga, for use with manual holder
Supelco
SPMEファイバーアセンブリー ジビニルベンゼン/カルボキセン/ポリジメチルシロキサン (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with autosampler
Supelco
SPMEファイバーアセンブリー ジビニルベンゼン/カルボキセン/ポリジメチルシロキサン (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with manual holder or autosampler, fiber L 2 cm
Supelco
SPMEファイバーアセンブリー ジビニルベンゼン/カルボキセン/ポリジメチルシロキサン (DVB/CAR/PDMS), needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPMEファイバーアセンブリー ポリジメチルシロキサン(PDMS), df 100 μm(PDMS, for use with autosampler, needle size 23 ga
Supelco
SPMEファイバーアセンブリー ポリジメチルシロキサン(PDMS), df 100 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
SPMEファイバーアセンブリー ポリジメチルシロキサン(PDMS), df 100 μm(PDMS, for use with autosampler, needle size 24 ga
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), df 75 μm(CAR/PDMS, for use with manual holder, needle size 24 ga
Supelco
SPMEファイバー・ポリジメチルシロキサン/ジビニルベンゼン(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPMEファイバーアセンブリー ポリアクリラート (PA), df 85 μm(PA, for use with autosampler, needle size 23 ga
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), df 85 μm(CAR/PDMS, needle size 23 ga, StableFlex, for use with autosampler
Supelco
SPMEファイバー・ポリジメチルシロキサン/ジビニルベンゼン(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with manual holder
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), df 75 μm(CAR/PDMS, needle size 24 ga, for use with autosampler
Supelco
SPMEファイバー・ポリジメチルシロキサン/ジビニルベンゼン(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 23 ga, PDMS/DVB StableFlex, for use with autosampler
Supelco
SPMEファイバー・ポリジメチルシロキサン/ジビニルベンゼン(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with manual holder
Supelco
SPMEファイバーアセンブリー ポリアクリラート (PA), df 85 μm(PA, for use with autosampler, needle size 24 ga
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, for use with manual holder, StableFlex fiber
Supelco
SPMEファイバー・ポリジメチルシロキサン/ジビニルベンゼン(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with autosampler
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with autosampler
Supelco
SPMEファイバーアセンブリー ポリジメチルシロキサン(PDMS), df 100 μm(PDMS, for use with manual holder, needle size 23 ga
Supelco
SPMEファイバー・ポリジメチルシロキサン/ジビニルベンゼン(PDMS/DVB), df 65 μm(PDMS/DVB, for use with autosampler, needle size 23 ga
Supelco
SPME StableFlexファイバー組み合わせキット, for use with manual holder
Supelco
SPMEファイバーアセンブリ、Carbowax・ポリエチレングリコール(PEG)コーティング, needle size 23 ga, df 60 μm(PEG, for use with autosampler
Supelco
SPME StableFlexファイバー組み合わせキット, needle size 23 ga, for use with autosampler
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with manual holder
Supelco
SPMEファイバー・ポリジメチルシロキサン/ジビニルベンゼン(PDMS/DVB), fused silica fiber, df 65 μm(PDMS/DVB, for use with manual holder, needle size 23 ga
Supelco
SPMEファイバーアセンブリー ポリアクリラート (PA), df 85 μm(PA, for use with manual holder, needle size 24 ga
Supelco