コンテンツへスキップ
Merck
  • Determination of transformation products of unsymmetrical dimethylhydrazine in water using vacuum-assisted headspace solid-phase microextraction.

Determination of transformation products of unsymmetrical dimethylhydrazine in water using vacuum-assisted headspace solid-phase microextraction.

Journal of chromatography. A (2018-05-03)
Dina Orazbayeva, Bulat Kenessov, Elefteria Psillakis, Dayana Nassyrova, Marat Bektassov
要旨

A new, sensitive and simple method based on vacuum-assisted headspace solid-phase microextraction (Vac-HSSPME) followed by gas chromatography-mass-spectrometry (GC-MS), is proposed for the quantification of rocket fuel unsymmetrical dimethylhydrazine (UDMH) transformation products in water samples. The target transformation products were: pyrazine, 1-methyl-1H-pyrazole, N-nitrosodimethylamine, N,N-dimethylformamide, 1-methyl-1Н-1,2,4-triazole, 1-methyl-imidazole and 1H-pyrazole. For these analytes and within shorter sampling times, Vac-HSSPME yielded detection limits (0.5-100 ng L-1) 3-10 times lower than those reported for regular HSSPME. Vac-HSSPME sampling for 30 min at 50 °C yielded the best combination of analyte responses and their standard deviations (<15%). 1-Formyl-2,2-dimethylhydrazine and formamide were discarded because of the poor precision and accuracy when using Vac-HSSPME. The recoveries for the rest of the analytes ranged between 80 and 119%. The modified Mininert valve and Thermogreen septum could be used for automated extraction as it ensured stable analyte signals even after long waiting times (>24 h). Finally, multiple Vac-HSSME proved to be an efficient tool for controlling the matrix effect and quantifying UDMH transformation products.

材料
製品番号
ブランド
製品内容

Supelco
SPMEファイバーアセンブリー ジビニルベンゼン/カルボキセン/ポリジメチルシロキサン (DVB/CAR/PDMS), needle size 24 ga, StableFlex
Supelco
SPMEファイバーアセンブリー ジビニルベンゼン/カルボキセン/ポリジメチルシロキサン (DVB/CAR/PDMS), needle size 24 ga, for use with manual holder
Supelco
SPMEファイバーアセンブリー ジビニルベンゼン/カルボキセン/ポリジメチルシロキサン (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with autosampler
Supelco
SPMEファイバーアセンブリー ジビニルベンゼン/カルボキセン/ポリジメチルシロキサン (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with manual holder or autosampler, fiber L 2 cm
Supelco
SPMEファイバーアセンブリー ジビニルベンゼン/カルボキセン/ポリジメチルシロキサン (DVB/CAR/PDMS), needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPMEファイバーアセンブリー ポリジメチルシロキサン(PDMS), df 100 μm(PDMS, needle size 24 ga, for use with manual holder
Supelco
SPMEファイバーアセンブリー ポリジメチルシロキサン(PDMS), df 100 μm(PDMS, for use with autosampler, needle size 23 ga
Supelco
SPMEファイバーアセンブリー ポリジメチルシロキサン(PDMS), df 100 μm(PDMS, for use with autosampler, needle size 24 ga
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), df 75 μm(CAR/PDMS, for use with manual holder, needle size 24 ga
Sigma-Aldrich
オクタメチルトリシロキサン, viscosity 1.0 cSt (25 °C)
Supelco
SPMEファイバー・ポリジメチルシロキサン/ジビニルベンゼン(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), df 85 μm(CAR/PDMS, needle size 23 ga, StableFlex, for use with autosampler
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler
Supelco
SPMEファイバー・ポリジメチルシロキサン/ジビニルベンゼン(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with manual holder
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), df 75 μm(CAR/PDMS, needle size 24 ga, for use with autosampler
Supelco
SPMEファイバーアセンブリー ポリアクリラート (PA), df 85 μm(PA, for use with autosampler, needle size 23 ga
Supelco
SPMEファイバー・ポリジメチルシロキサン/ジビニルベンゼン(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 23 ga, PDMS/DVB StableFlex, for use with autosampler
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, for use with manual holder, StableFlex fiber
Supelco
SPMEファイバーアセンブリー ポリアクリラート (PA), df 85 μm(PA, for use with autosampler, needle size 24 ga
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with autosampler
Supelco
SPMEファイバー・ポリジメチルシロキサン/ジビニルベンゼン(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, for use with autosampler
Supelco
SPMEファイバー・ポリジメチルシロキサン/ジビニルベンゼン(PDMS/DVB), df 65 μm(PDMS/DVB, needle size 24 ga, StableFlex, for use with manual holder
Supelco
SPMEファイバーアセンブリー ポリジメチルシロキサン(PDMS), df 100 μm(PDMS, for use with manual holder, needle size 23 ga
Supelco
SPMEファイバーアセンブリ、Carbowax・ポリエチレングリコール(PEG)コーティング, needle size 23 ga, df 60 μm(PEG, for use with autosampler
Supelco
SPME StableFlexファイバー組み合わせキット, for use with manual holder
Supelco
SPMEファイバー・ポリジメチルシロキサン/ジビニルベンゼン(PDMS/DVB), df 65 μm(PDMS/DVB, for use with autosampler, needle size 23 ga
Supelco
SPMEファイバー・アセンブリカルボキセン/ポリジメチルシロキサン(CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with manual holder
Supelco
SPME StableFlexファイバー組み合わせキット, needle size 23 ga, for use with autosampler
Supelco
SPMEファイバー・ポリジメチルシロキサン/ジビニルベンゼン(PDMS/DVB), fused silica fiber, df 65 μm(PDMS/DVB, for use with manual holder, needle size 23 ga
Supelco
SPMEファイバーアセンブリー ポリアクリラート (PA), df 85 μm(PA, for use with manual holder, needle size 24 ga