コンテンツへスキップ
Merck
  • The influence of secondary processing on the structural relaxation dynamics of fluticasone propionate.

The influence of secondary processing on the structural relaxation dynamics of fluticasone propionate.

AAPS PharmSciTech (2014-11-16)
Roberto Depasquale, Sau L Lee, Bhawana Saluja, Jagdeep Shur, Robert Price
要旨

This study investigated the structural relaxation of micronized fluticasone propionate (FP) under different lagering conditions and its influence on aerodynamic particle size distribution (APSD) of binary and tertiary carrier-based dry powder inhaler (DPI) formulations. Micronized FP was lagered under low humidity (LH 25 C, 33% RH [relative humidity]), high humidity (HH 25°C, 75% RH) for 30, 60, and 90 days, respectively, and high temperature (HT 60°C, 44% RH) for 14 days. Physicochemical, surface interfacial properties via cohesive-adhesive balance (CAB) measurements and amorphous disorder levels of the FP samples were characterized. Particle size, surface area, and rugosity suggested minimal morphological changes of the lagered FP samples, with the exception of the 90-day HH (HH90) sample. HH90 FP samples appeared to undergo surface reconstruction with a reduction in surface rugosity. LH and HH lagering reduced the levels of amorphous content over 90-day exposure, which influenced the CAB measurements with lactose monohydrate and salmeterol xinafoate (SX). CAB analysis suggested that LH and HH lagering led to different interfacial interactions with lactose monohydrate but an increasing adhesive affinity with SX. HT lagering led to no detectable levels of the amorphous disorder, resulting in an increase in the adhesive interaction with lactose monohydrate. APSD analysis suggested that the fine particle mass of FP and SX was affected by the lagering of the FP. In conclusion, environmental conditions during the lagering of FP may have a profound effect on physicochemical and interfacial properties as well as product performance of binary and tertiary carrier-based DPI formulations.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
メタノール, JIS special grade, ≥99.8%
Sigma-Aldrich
ポリ(テトラフルオロエチレン), powder (free-flowing), 1 μm particle size
Sigma-Aldrich
D-ラクトース 一水和物, ≥99% (HPLC), BioUltra
Sigma-Aldrich
アセトン, JIS special grade, ≥99.5%
Sigma-Aldrich
D-ラクトース 一水和物, ≥98.0% (HPLC)
Sigma-Aldrich
メタノール, SAJ first grade, ≥99.5%
Sigma-Aldrich
D.E.R. 332, used as embedding medium
Sigma-Aldrich
アセトニトリル, anhydrous, 99.8%
Sigma-Aldrich
メタノール, anhydrous, 99.8%
Sigma-Aldrich
ポリ(テトラフルオロエチレン), powder, >40 μm particle size
Sigma-Aldrich
アセトン, natural, ≥97%
Sigma-Aldrich
アセトン, SAJ first grade, ≥99.0%
Sigma-Aldrich
アセトン, ≥99%, meets FCC analytical specifications
Sigma-Aldrich
アセトニトリル, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
ポリ(テトラフルオロエチレン), powder, 200 μm particle size
Sigma-Aldrich
メタノール, SAJ special grade
Sigma-Aldrich
メタノール, suitable for HPLC
Sigma-Aldrich
アセトニトリル, ≥99.8%, suitable for HPLC
Sigma-Aldrich
シクロヘキサン, anhydrous, 99.5%
Sigma-Aldrich
ポリ(テトラフルオロエチレン), beads
Sigma-Aldrich
ポリ(テトラフルオロエチレン), powder, 35 μm particle size
Sigma-Aldrich
シクロヘキサン, JIS special grade
Sigma-Aldrich
アセトン, ≥99.5%, for residue analysis
Sigma-Aldrich
ポリ(テトラフルオロエチレン), powder (free-flowing), ≤12 μm particle size
Sigma-Aldrich
ポリ(テトラフルオロエチレン), powder, ≥350 μm particle size
Sigma-Aldrich
メタノール, NMR reference standard
Sigma-Aldrich
アセトニトリル, ≥99.8%, for residue analysis, JIS 300
Sigma-Aldrich
アセトニトリル, JIS special grade, ≥99.5%
Sigma-Aldrich
アセトン, for residue analysis, ≥99.5%
Sigma-Aldrich
D-ラクトース 一水和物, ACS reagent