コンテンツへスキップ
Merck
  • Does the experience level of the radiologist, assessment in consensus, or the addition of the abduction and external rotation view improve the diagnostic reproducibility and accuracy of MRA of the shoulder?

Does the experience level of the radiologist, assessment in consensus, or the addition of the abduction and external rotation view improve the diagnostic reproducibility and accuracy of MRA of the shoulder?

Clinical radiology (2014-09-15)
S van Grinsven, F Hagenmaier, C J M van Loon, M J van Gorp, M J van Kints, A van Kampen
要旨

To prospectively evaluate the influence of observer experience, consensus assessment, and abduction and external rotation (ABER) view on the diagnostic performance of magnetic resonance arthrography (MRA) in patients with traumatic anterior-shoulder instability (TASI). Fifty-eight MRA examinations (of which 51 had additional ABER views) were assessed by six radiologists (R1-R6) and three teams (T1-T3) with different experience levels, using a seven-lesion standardized scoring form. Forty-five out of 58 MRA examination findings were surgically confirmed. Kappa coefficients, sensitivity, specificity, and differences in percent agreement or correct diagnosis (p-value, McNemar's test) were calculated per lesion and overall per seven lesion types to assess diagnostic reproducibility and accuracy. Overall kappa ranged from poor (k = 0.17) to moderate (k = 0.53), sensitivity from 30.6-63.5%, and specificity from 73.6-89.9%. Overall, the most experienced radiologists (R1-R2) and teams (T2-T3) agreed significantly more than the lesser experienced radiologists (R3-R4: p = 0.014, R5-R6; p = 0.018) and teams (T2-T3: p = 0.007). The most experienced radiologist (R1, R2, R3) and teams (T1, T2) were also consistently more accurate than the lesser experienced radiologists (R4, R5, R6) and team (T3). Significant differences were found between R1-R4 (p = 0.012), R3-R4 (p = 0.03), and T2-T3 (p = 0.014). The overall performance of consensus assessment was systematically higher than individual assessment. Significant differences were established between T1-T2 and radiologists R3-R4 (p<0.001, p = 0.001) and between T2 and R3 (p<0.001/p = 0.001) or R4 (p = 0.050). No overall significant differences were found between the radiologists' assessments with and without ABER. The addition of ABER does not significantly improve overall diagnostic performance. The radiologist's experience level and consensus assessment do contribute to higher reproducibility and accuracy.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
ヨウ素, ACS reagent, ≥99.8%, solid
Sigma-Aldrich
Histodenz, nonionic density gradient medium
Sigma-Aldrich
ヨウ素, flakes, ReagentPlus®, ≥99%
Supelco
ヨウ素, ReagentPlus®, ≥99.8% (titration)
Sigma-Aldrich
ヨウ素, ≥99.99% trace metals basis
Sigma-Aldrich
ヨウ素, puriss., meets analytical specification of Ph. Eur., BP, USP, 99.8-100.5%
Sigma-Aldrich
ヨウ素, ReagentPlus®, 99.7% trace metals basis, beads, 1-3 mm
Sigma-Aldrich
ヨウ素, 99.999% trace metals basis
Sigma-Aldrich
ヨウ素, anhydrous, beads, −10 mesh, 99.999% trace metals basis
Sigma-Aldrich
N-メチル-D-グルカミン, 99.0-100.5% (titration)
Sigma-Aldrich
ヨウ素, puriss., ≥99.5% (RT), particles (round)
Sigma-Aldrich
ガドリニウム, chips
Sigma-Aldrich
N-メチル-D-グルカミン, ReagentPlus®, ≥99.0% (T)
Sigma-Aldrich
ヨウ素, JIS special grade, ≥99.8%
Sigma-Aldrich
ガドリニウム, −40 mesh, 99% trace rare earth metals basis
Sigma-Aldrich
ヨウ素, SAJ first grade, ≥99.0%
Supelco
Iohexol, analytical standard
Sigma-Aldrich
Meglumine, 99.0-100.5% dry basis, meets USP testing specifications
ガドリニウム, rod, 50mm, diameter 6.35mm, cast, 99%
ガドリニウム, rod, 100mm, diameter 12.5mm, cast, 99%
Iohexol, European Pharmacopoeia (EP) Reference Standard
ガドリニウム, rod, 100mm, diameter 6.35mm, cast, 99%
ガドリニウム, rod, 48mm, diameter 3.0mm, cast, 99%
ガドリニウム, rod, 50mm, diameter 12.5mm, cast, 99%
N-メチル-D-グルカミン, European Pharmacopoeia (EP) Reference Standard
Supelco
N-メチル-D-グルカミン, Pharmaceutical Secondary Standard; Certified Reference Material
ガドリニウム, wire reel, 25mm, diameter 0.5mm, hard, 99.9%
ガドリニウム, wire reel, 100mm, diameter 0.5mm, hard, 99.9%
ガドリニウム, wire reel, 50mm, diameter 0.5mm, hard, 99.9%
ガドリニウム, rod, 100mm, diameter 3.0mm, cast, 99%