おすすめの製品
由来生物
goat
抗体製品の状態
affinity isolated antibody
抗体製品タイプ
secondary antibodies
クローン
polyclonal
フォーム
buffered aqueous solution
交差性
rabbit
濃度
~1 mg/mL
蛍光検出
λex 638 nm; λem 655 nm in PBS, pH 7.4
保管温度
−20°C
詳細
Abberior STAR RED is a well-known red dye, named also KK114 in literature. It was developed for STED and confocal imaging in the red spectral region. It shows an exceptional brightness and low background, delivering stunning STED images. The dye works extremely well with Abberior Instruments STEDYCON and Expert Line microscopes and Leica STED microscopes. Abberior STAR RED can substitute dyes like Atto™ 647N, Alexa Fluor™ 647, or Cy®5. It can be excited with lasers at wavelength between 630 - 650 nm. For STED, a depletion wavelength around 750 - 800 nm is recommended. Abberior STAR RED is the ideal partner for Abberior STAR 580 to obtain optimal 2 Color STED results. Best results are obtained with freshly prepared samples.
Photophysical properties (carboxylic acid):
Absorption Maximum, λex [nm]: 638 (PBS pH 7.4), 638 (H2O), 634 (MeOH)
Extinction Coefficient, εmax [M-1cm-1]: 120 000 (PBS pH 7.4), 125 000 (H2O), 115 000 (MeOH)
Correction Factor, CF260 = ε260/εmax: 0,16 (PBS pH 7.4)
Correction Factor, CF280 = ε280/εmax: 0,32 (PBS pH 7.4)
Fluorescence Maximum, λem [nm]: 655 (PBS pH 7.4), 655 (H2O), 654 (MeOH)
Recommended STED Wavelength, λ [nm]: 750-800
Fluorescence Quantum Yield, λ: 0,90 (PBS pH 7.4)
Fluorescence Lifetime, τ [ns]: 3,4 (PBS pH 7.4)
Photophysical properties (carboxylic acid):
Absorption Maximum, λex [nm]: 638 (PBS pH 7.4), 638 (H2O), 634 (MeOH)
Extinction Coefficient, εmax [M-1cm-1]: 120 000 (PBS pH 7.4), 125 000 (H2O), 115 000 (MeOH)
Correction Factor, CF260 = ε260/εmax: 0,16 (PBS pH 7.4)
Correction Factor, CF280 = ε280/εmax: 0,32 (PBS pH 7.4)
Fluorescence Maximum, λem [nm]: 655 (PBS pH 7.4), 655 (H2O), 654 (MeOH)
Recommended STED Wavelength, λ [nm]: 750-800
Fluorescence Quantum Yield, λ: 0,90 (PBS pH 7.4)
Fluorescence Lifetime, τ [ns]: 3,4 (PBS pH 7.4)
特徴および利点
- Unmatched, background free STED imaging cont
- Verified in Abberior Instruments and Leica STED microscopes
適合性
Designed and tested for fluorescent super-resolution microscopy
アナリシスノート
May contain significant amounts of BSA as stabilizer
unconjugated dye ≤5% of total fluorescence
unconjugated dye ≤5% of total fluorescence
法的情報
ALEXA FLUOR is a trademark of Life Technologies
Atto is a trademark of Atto-Tec GmbH
Cy is a registered trademark of Cytiva
abberior is a registered trademark of Abberior GmbH
適切な製品が見つかりませんか。
製品選択ツール.をお試しください
保管分類コード
12 - Non Combustible Liquids
WGK
WGK 3
引火点(°F)
Not applicable
引火点(℃)
Not applicable
Céline Guilbeau-Frugier et al.
Cardiovascular research, 115(6), 1078-1091 (2018-10-18)
This study explored the lateral crest structures of adult cardiomyocytes (CMs) within healthy and diseased cardiac tissue. Using high-resolution electron and atomic force microscopy, we performed an exhaustive quantitative analysis of the three-dimensional (3D) structure of the CM lateral surface
Sinem K Saka et al.
Nature communications, 5, 4509-4509 (2014-07-26)
Most proteins have uneven distributions in the plasma membrane. Broadly speaking, this may be caused by mechanisms specific to each protein, or may be a consequence of a general pattern that affects the distribution of all membrane proteins. The latter
Kirill Kolmakov et al.
Chemistry (Weinheim an der Bergstrasse, Germany), 20(1), 146-157 (2013-12-18)
The synthesis, reactivity, and photophysical properties of new rhodamines with intense red fluorescence, two polar residues (hydroxyls, primary phosphates, or sulfonic acid groups), and improved hydrolytic stability of the amino-reactive sites (NHS esters or mixed N-succinimidyl carbonates) are reported. All
Alf Honigmann et al.
eLife, 3, e01671-e01671 (2014-03-20)
The eukaryotic cell membrane is connected to a dense actin rich cortex. We present FCS and STED experiments showing that dense membrane bound actin networks have severe influence on lipid phase separation. A minimal actin cortex was bound to a
Roman Schmidt et al.
Nano letters, 9(6), 2508-2510 (2009-05-23)
Because of the diffraction resolution barrier, optical microscopes have so far failed in visualizing the mitochondrial cristae, that is, the folds of the inner membrane of this 200 to 400 nm diameter sized tubular organelle. Realizing a approximately 30 nm
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)