コンテンツへスキップ
Merck

RCI1MAG-87K

Millipore

MILLIPLEX® Rat Cardiac Injury Panel 1 - Cardiotoxicity Multiplex Assay

ログイン組織・契約価格を表示する


About This Item

UNSPSCコード:
12161503
eCl@ss:
32161000
NACRES:
NA.84

化学種の反応性

rat

品質水準

メーカー/製品名

Milliplex®

assay range

recovery range: 80-100%
(2 Hour Protocol)

recovery range: 86-103%
(Overnight Protocol)

sensitivity: 7-155 pg/mL
(Overnight Protocol; MinDC+2SD)

sensitivity: 9-86 pg/mL
(2 Hour Protocol; MinDC+2SD)

standard curve range: 123-90,000 pg/mL
(cTnI)

standard curve range: 21-15,000 pg/mL
(CKM)

standard curve range: 4-3,000 pg/mL
(MYL3)

standard curve range: 41-30,000 pg/mL
(FABP3)

standard curve range: 41-30,000 pg/mL
(TIMP-1)

standard curve range: 82-60,000 pg/mL
(FSTL1)

standard curve range: 82-60,000 pg/mL
(cTnT)

テクニック

multiplexing: suitable

検出方法

fluorometric (Luminex xMAP)

輸送温度

wet ice

詳細

Drug-induced cardiotoxicity can be life threatening and necessitates limiting an otherwise-effective treatment. In fact, cardiovascular toxicity has been reported to account for over 40% of drug candidate withdrawal in premarketing clinical trials. Many therapeutic agents have been reported to induce or exacerbate heart failure including anti-tumor medications, immunomodulating drugs, antidepressants, and calcium channel blocking agents to name a few. Conventional biomarkers of cardiotoxicity such as aspartate aminotransferase (AST), lactate dehydrogenase (LDH) and creatine kinase (CK) have gradually been withdrawn due to low tissue specificity. The number of cardiac-specific biomarkers adapted from clinical studies of cardiotoxicity continues to rise. The reverse translational application of these auspicious biomarkers in experimental animal models could improve the power of detection for diagnosis, helping to predict the occurrence of cardiotoxicity in humans. Emerging biomarkers of cardiac injury include multiple categories of proteins: characteristic muscle cell proteins (cTnI, cTnT, FABP3 and MYL3), cytosolic kinase (CKM), secreted heparin-binding protein (FSTL1) and metalloprotease inhibitor (TIMP1). Numerous studies have demonstrated elevated levels of these biomarkers in experimental animal blood samples.

In order to meet the increasing need to provide screening assays for experimental biomarkers of drug-induced cardiac injury in pre-clinical and translational research models, we have developed the MILLIPLEX® Rat Cardiac Injury Bead Panel 1. This configurable 7-plex panel is the most versatile system available for cardiac injury screening in pre-clinical and translational research models.

The MILLIPLEX® Rat Cardiac Injury Bead Panel 1 (RCI1MAG-87K) contains all the components necessary to simultaneous quantify any or all of the following 7 analytes in serum and plasma samples: Cardiac Troponin I (cTnI), Cardiac Troponin T (cTnT), Creatine Kinase, Muscle (CKM), Fatty Acid Binding Protein 3 (FABP3), Follistatin-like Protein 1 (FSTL1), Myosin Light Chain 3 (MYL3), Tissue Inhibitor of Metalloproteinase-1 (TIMP-1).

This kit uses a 96-well format, contains lyophilized standard cocktail and two quality controls, and can measure up to 38 serum or plasma samples in duplicate.

Panel Type: Toxicity
The MILLIPLEX® MAP Rat Cardiac Injury Magnetic Bead Panel 1 is a configurable 7-plex kit for the quantification of cTnI, cTnT, CKM (MM-CK), FABP3, FSTL1, MYL3, and TIMP-1 in serum or plasma samples on the Luminex xMAP instrument platform.

特異性

Cross Reactivty
There was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes within a panel.

アプリケーション

  • Analytes: Cardiac Troponin I (cTnI), Cardiac Troponin T (cTnT), Creatine Kinase Muscle (CKM), Fatty Acid Binding Protein 3 (FABP3), Follistatin-like Protein 1 (FSTL1), Myosin Light Chain 3 (MYL3), Tissue Inhibitor of Metalloproteinase-1 (TIMP-1)
  • Recommended Sample Type: Rat serum or plasma
  • Recommended Sample dilution: 25 μL per well of 1:5 diluted serum or plasma
  • Assay Run Time: Overnight (16-18 hours) at 2-8°C or 2 hours at room temperature (20-25°C).
  • Research Category: Toxicity
  • Research Subcategory: Cardiovascular

特徴および利点

Design your multiplex kit by choosing available analytes within this panel.

包装

Everything you need in a single kit.

構成

Rat Cardiac Injury Standard, 1 vial, lyophilized

Rat Cardiac Injury Quality Control 1, 1 vial, lyophilized

Rat Cardiac Injury Quality Control 2, 1 vial, lyophilized

Serum Matrix (0.08% Sodium Azide), 1 vial, lyophylized

Assay Buffer, 1 bottle, 30 mL

Wash Buffer, 10X (0.05% Proclin), 2 bottles, 30 mL ea

Rat Cardiac Injury Panel 1 Detection Antibodies, 1 bottle, 3.2 mL

Rat Cardiac Injury Panel 1 Antibody-Immobilized Beads (20X), 200 µL ea

Streptavidin-Phycoerythrin, 1 bottle, 3.2 mL

Mixing Bottle, 1 bottle

Sample Plate, 96 well format, 1 plate

2 Foil Plate Sealers

保管および安定性

Recommended storage for kit components is 2 - 8°C.

その他情報

Please contact Technical Service for linearity of dilution.
Please refer to Assay Protocol for individual analyte accuracy.
Sensitivity: Please see kit protocol for assay sensitivities of individual analytes.

法的情報

MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany

免責事項

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

ピクトグラム

Skull and crossbonesHealth hazardCorrosionEnvironment

シグナルワード

Danger

危険有害性の分類

Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2

ターゲットの組織

Respiratory Tract

保管分類コード

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

Jan Code

RCI1MAG-87K-01:
RCI1MAG-87K:
RCI1MAG-87K-04:
RCI1MAG-87K-02:
RCI1MAG-87K-07:
RCI1MAG-87K-06:
RCI1MAG-87K-03:
RCI1MAG-87K-05:


試験成績書(COA)

製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

関連コンテンツ

UnEnhance research with MILLIPLEX® multiplexing tips, industry guidance, and one-day assays for limited lab time.

実験動物、コンパニオンアニマル、農業用動物の研究におけるバイオマーカー検出マルチプレックス・イムノアッセイの利点と、獣医学および動物衛生研究のためのMILLIPLEX®マルチプレックスアッセイについて説明します。

Discover the benefits of MILLIPLEX® multiplex assays, based on Luminex® xMAP® multiplex assay technology, that provide consistent, high-quality results and see how these multiplex biomarker Luminex® assays are being used to advance research.

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)