コンテンツへスキップ
Merck

P3B010A05

Millipore

Pellicon® 3カセット、Biomax® メンブレン付き

10kDa, A Screen, 0.57 m2

別名:

Pellicon® 3 Cassette with Biomax 10 kDa Membrane, A screen, 0.57 m2

ログイン組織・契約価格を表示する


About This Item

UNSPSCコード:
23151806
eCl@ss:
32031623

物質

TPE seal
polyethersulfone
polypropylene screen
stainless steel cap (for end; polypropylene-encapsulated)

品質水準

特徴

holdup volume 69 mL (in feed channel)

メーカー/製品名

Pellicon®

パラメーター

30 psi max. reverse press. exposure at 25 °C (for 24 hours)
4-6 L/min-m2 recirculation rate
40 psi max. transmembrane pressure at 4-50 °C
6.9 bar max. inlet pressure (100 psi)
80 psi max. transmembrane pressure at 4-40 °C

テクニック

analytical sample preparation: suitable
buffer exchange: suitable
protein purification: suitable (concentration)

H

2.4 cm (0.93 in.)

L

20.6 cm (8.1 in.)

W

17.8 cm (7 in.)

膜面積

0.57 m2

重量分析抽出物

≤1500 mg/m2

マトリックス

Biomax® (Membrane)

ポアサイズ

10 kDa NMWCO

pH

1-14

類似した製品をお探しですか? 訪問 製品比較ガイド

詳細

Pellicon® 3 filtration devices are advanced, high-performance cassettes ideal for today’s higher titer therapeutic antibodies as well as the more demanding filtration processes that require higher operating pressures, temperatures and caustic cleaning regimes.

The Pellicon® 3 Cassette with Biomax® Membrane is perfect for the filtration of monoclonal antibodies and solutions containing albumin, hormones, vaccines and growth factors.

This P3B010A05 Pellicon® 3 ultrafiltration device features a pore size of 10 kDa NMWCO, a Biomax® 10 membrane, and dimensions measuring 2.4 cm (H) x 17.8 cm (W) x 20.6 cm (L).

特徴および利点

  • Rugged & reliable – ideally suited for today′s more demanding filtration processes
  • High performance – produces excellent resolution, yields and back-pressure resistance
  • Optimum product recovery – thanks to proven membrane technology
  • Void-free technology – leading-edge membranes resolve virtually any separation challenge
  • Defect-free, superior adhesion – Ultracel®uses composite membranes cast on a microporous substrate
  • Automated manufacturing – delivers unbeatable performance, consistency and reliability
  • Easy installation & care – simple to install and maintain

その他情報

These products are manufactured in a facility which adheres to Good Manufacturing Practices.

アナリシスノート

Gravimetric Extractables: after 24 hours in water at controlled room temperature

法的情報

BIOMAX is a registered trademark of Merck KGaA, Darmstadt, Germany
Pellicon is a registered trademark of Merck KGaA, Darmstadt, Germany
ULTRACEL is a registered trademark of Merck KGaA, Darmstadt, Germany

保管分類コード

8B - Non-combustible corrosive hazardous materials

WGK

WGK 1


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。