コンテンツへスキップ
Merck
すべての画像(1)

主要文書

安全性情報

HTS024M

Sigma-Aldrich

ChemiSCREEN Membrane Preparation Recombinant Human CRF 2 Neuropeptide Receptor

ログイン組織・契約価格を表示する


About This Item

UNSPSCコード:
41106514
eCl@ss:
32161000
Pricing and Inventory is not available. Please check the Merck website for more information.

由来生物

human

リコンビナント

expressed in Chem-1 cells

フォーム

liquid

メーカー/製品名

ChemiScreen
Chemicon®

テクニック

ligand binding assay: suitable (GTPγS)
radioligand binding assay (RLBA): suitable

NCBIアクセッション番号

UniProtアクセッション番号

詳細

Full-length human CRHR2 cDNA encoding CRF2
The corticotropin-releasing factor receptors, CRF1 and CRF2, are Gs-coupled GPCRs expressed in the brain, blood vessels and intestine that bind to several neuropeptides, including corticotropin-releasing factor (CRF) and urocortin, and the amphibian peptide sauvagine (Lovenberg et al., 1995; Bale and Vale, 2004). In addition, two peptides, urocortin II (Ucn II) and urocortin III (Ucn III), bind selectively and with high affinity to CRF2 (Lewis et al., 2001). The CRF peptides and their receptors play important roles in stress mediated by the hypothalamic-pituitary-adrenal axis in animal models, and possibly in depression and anxiety in humans, although the contributions of CRF1 and CRF2 appear to be distinct (Bale and Vale, 2004; Risbrough et al., 2004) In addition, CRF1 and CRF2 differentially alter feeding behavior, gastric motility and vascular tone (Zorrilla et al., 2004; Martinez et al., 2004; Wiley and Davenport, 2004). Millipore′s CRF2 membrane preparations are crude membrane preparations made from our proprietary stable recombinant cell lines to ensure high-level of GPCR surface expression; thus, they are ideal HTS tools for screening of antagonists of CRF2 interactions with its ligands. The membrane preparations exhibit a Kd of 0.65 nM for [125I]-sauvagine. With 5 μg/well CRF2 Membrane Prep and 0.35 nM [125I]-sauvagine, a greater than 20-fold signal-to-background ratio is obtained.

アプリケーション

Human CRF2 GPCR membrane preparation for Radioligand binding Assays & GTPgammaS binding.
Radioligand binding assay, and GTPgammaS binding.

生物化学的/生理学的作用

  • GPCR Class: B
  • Protein Target: CRF2
  • Target Sub-Family: CRF Receptor

品質

Signal:background and specific binding values obtained in a competition binding assay with CRF2 membrane preparation.
5 μg/well
Signal:Background 64.6
Specific Binding (cpm): 38718

SPECIFICATIONS: 1 unit = 5 μg
Bmax: 9.04 pmol/mg protein
Kd : 0.65 nM

規格

RECOMMENDED ASSAY CONDITIONS: Membranes are mixed with radioactive ligand and unlabeled competitor (see Figures 1 and 2 for concentrations tested) in binding buffer in a nonbinding 96-well plate, and incubated for 1-2 h. Prior to filtration, an FC 96-well harvest plate (Millipore cat. # MAHF C1H) is coated with 0.33% polyethyleneimine for 30 min, then washed with 50mM HEPES, pH 7.4, 0.5% BSA. Binding reaction is transferred to the filter plate, and washed 3 times (1 mL per well per wash) with Wash Buffer. The plate is dried and counted.

Binding buffer: 50 mM Hepes, pH 7.4, 5 mM MgCl2, 1 mM CaCl2, 0.2% BSA, filtered and stored at 4°C

Radioligand: [125I] Sauvagine (Perkin Elmer#:NEX306)

Wash Buffer: 50 mM Hepes, pH 7.4, 500mM NaCl , 0.1% BSA, filtered and stored at 4°C.

One vial contains enough membranes for at least 200 assays (units), where an unit is the amount of membrane that will yield greater than 20-fold signal:background with 125I-labeled Sauvagine at 0.35 nM

物理的形状

Liquid in packaging buffer: 50 mM Tris pH 7.4, 10% glycerol and 1% BSA no preservatives.Packaging method: Membranes protein were adjusted to 0.5 mg/ml in 1 ml packaging buffer, rapidly frozen, and stored at -80°C.

保管および安定性

Maintain frozen at -70°C for up to 2 years. Do not freeze and thaw.

法的情報

CHEMICON is a registered trademark of Merck KGaA, Darmstadt, Germany

免責事項

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial

保管分類コード

12 - Non Combustible Liquids

WGK

WGK 2

引火点(°F)

Not applicable

引火点(℃)

Not applicable


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

Jan Code

HTS024M:


試験成績書(COA)

製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。

以前この製品を購入いただいたことがある場合