コンテンツへスキップ
Merck

262897

Sigma-Aldrich

タンタル

foil, thickness 0.25 mm, ≥99.9% trace metals basis

別名:

Ta

ログイン組織・契約価格を表示する


About This Item

実験式(ヒル表記法):
Ta
CAS番号:
分子量:
180.95
EC Number:
MDL番号:
UNSPSCコード:
12141741
PubChem Substance ID:
NACRES:
NA.23

蒸気圧

<0.01 mmHg ( 537.2 °C)

品質水準

アッセイ

≥99.9% trace metals basis

形状

foil

自己発火温度

572 °F

抵抗性

13.5 μΩ-cm, 20°C

厚さ

0.25 mm

bp

5425 °C (lit.)

mp

2996 °C (lit.)

密度

16.69 g/cm3 (lit.)

SMILES記法

[Ta]

InChI

1S/Ta

InChI Key

GUVRBAGPIYLISA-UHFFFAOYSA-N

関連するカテゴリー

詳細

The structure of tantalum is body centered cubic (BCC) metal. It is a refractory metal; stable up to very high temperatures. Tantalum is ductile at room temperature and moderately ductile at cryogenic temperatures. Compton profile of highly pure thin elemental foil of tantalum was investigated using IGP type coaxial photon detector.1

数量

50x50 mm (approximately 10.4 g)
100x100 mm (approximately 41.6 g)

保管分類コード

11 - Combustible Solids

WGK

nwg

引火点(°F)

Not applicable

引火点(℃)

Not applicable

個人用保護具 (PPE)

Eyeshields, Gloves, type N95 (US)


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

労働安全衛生法名称等を表示すべき危険物及び有害物

名称等を表示すべき危険物及び有害物

労働安全衛生法名称等を通知すべき危険物及び有害物

名称等を通知すべき危険物及び有害物

Jan Code

262897-VAR:
262897-100CM2-PW:
262897-100CM2:
262897-41.6G-PW:
262897-25CM2-PW:
262897-25CM2:
262897-BULK:
262897-10.4G:
262897-10.4G-PW:
262897-41.6G:


試験成績書(COA)

製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

この製品を見ている人はこちらもチェック

Slide 1 of 6

1 of 6

タンタル foil, 100x100mm, thickness 0.100mm, annealed, 99.9%

GF76534500

タンタル

タンタル

Sigma-Aldrich

545007

タンタル

タンタル powder, &#8722;325&#160;mesh, 99.9% trace metals basis

Sigma-Aldrich

262846

タンタル

ニオブ foil, thickness 0.25&#160;mm, 99.8% trace metals basis

Sigma-Aldrich

262781

ニオブ

ケイ素 wafer (single side polished), &#60;111&#62;, N-type, contains no dopant, diam. × thickness 2&#160;in. × 0.5&#160;mm

Sigma-Aldrich

647101

ケイ素

The Morphology of Tensile Failure in Tantalum
Boyce BL, et al.
Metallurgical and Materials Transactions A: Physical Metallurgy and Materials Science, 44(10), 4567-4580 (2013)
Frédéric Clarençon et al.
Journal of neurosurgery. Spine, 18(6), 606-610 (2013-04-23)
Presurgical devascularization of hypervascular spinal metastases has been shown to be effective in preventing major blood loss during open surgery. Most often, embolization can be performed using polyvinyl alcohol (PVA) microparticles. However, in some cases, the close relationship between the
A M Ashmore et al.
Journal of biomechanics, 45(16), 2931-2934 (2012-10-13)
Interest in soft tissue RadioStereometric Analysis (RSA) is rising. Previous studies have attempted to use this technique to analyse anterior cruciate ligament (ACL) graft constructs, and more recently, the movement of soft tissue as a precursor to RSA follow up
Orbital ultrasound in the selective screening of a dural-cavernous sinus fistula.
Hamid Shokoohi et al.
European journal of emergency medicine : official journal of the European Society for Emergency Medicine, 20(2), 137-139 (2013-02-26)
Thomas Larzon et al.
Vascular, 21(2), 87-91 (2013-03-20)
Control of back bleeding from the hypogastric artery into the aneurysm after endovascular aneurysm repair (EVAR) of a ruptured aorto-iliac aneurysm may be necessary in order to avoid a type II endoleak. It is an emergency situation and selective catheterization

資料

Biomedical implants are essentially foreign substances within the human body that must survive many years’ exposure to demanding mechanical and physiological conditions. Despite these challenges, metal implants have been widely used to substitute for or rebuild hard tissues such as bones and teeth.

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)