Passa al contenuto
Merck
Tutte le immagini(9)

Documenti fondamentali

MFHV00025

Millipore

Milliflip®-HV Non-sterile Vacuum-driven PVDF Filter Unit

Nonsterile, 50 mL process volume, 0.45 µm pore size, PVDF membrane

Sinonimo/i:

PVDF nonsterile filter unit, tube top vacuum filter

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali

Scegli un formato

25 EACH
136,00 €

136,00 €


Disponibile per la spedizione il11 aprile 2025Dettagli


Richiedi un campione

Scegli un formato

Cambia visualizzazione
25 EACH
136,00 €

About This Item

Codice UNSPSC:
41104921
NACRES:
NB.24

136,00 €


Disponibile per la spedizione il11 aprile 2025Dettagli


Richiedi un campione

Materiali

PVDF filter membrane
acrylic housing
polypropylene

Livello qualitativo

Sterilità

non-sterile

Caratteristiche

holdup volume 0.6 mL
hydrophilic

Confezionamento

pack of 25 ea

Parametri

max. temp. at 45 °C

tecniche

vacuum filtration: suitable

Altezza

138 mm

Capacità

50 mL

Diametro

6.4 cm

Diam. filtro

4 cm

Superficie filtrante

7 cm2

Capacità imbuto

50 mL

Matrice

Durapore®

Dimensione pori

0.45 μm pore size

Raccordi

double lead thread inlet (with vacuum port)
double lead thread inlet for 50 mL centrifuge tube

Condizioni di spedizione

ambient

Descrizione generale

The Milliflip® filter unit is a disposable, vacuum-driven nonsterile filtration system used in the pre-filtration and clarification of water, buffers and aqueous solutions. It is designed to work with standard 50 mL centrifuge tubes, which eliminates sample transfer.

Applicazioni

Nonsterile vacuum filtration of water, buffers and aqueous solutions

Caratteristiche e vantaggi

Eliminates messy sample transfer via simple vacuum-assisted system; attaches to any standard 50 ml centrifuge tube eliminating unnecessary materials and risk of spilage; ideal for nonsterile filtration of aqueous and organic solutions used in analytical sample preparation; convenient blue stand helps to hold the filter unit during filtration;

Note legali

Durapore is a registered trademark of Merck KGaA, Darmstadt, Germany
MilliFlip is a registered trademark of Merck KGaA, Darmstadt, Germany

Certificati d'analisi (COA)

Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Domande

1–10 di 17 domande  
  1. Can one remove the filter and/or use with an additional filter?

    1 risposta
    1. These devices are intended for single use only, and the membrane cannot be removed or changed.

      Utile?

  2. Can I use the filter itself for further investigation or is it packed and sealed?

    1 risposta
    1. These devices are designed to be single use only, and the membrane is not removable/changeable.

      Utile?

  3. Does the tube holder come with it?

    1 risposta
    1. Yes, this product includes one tube stand per box of 25 devices. Please see the link below to review additional information available in the product datasheet:
      https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/204/618/20767821-ms.pdf

      Utile?

  4. What is a Milliflip™ filter unit?

    1 risposta
    1. The nonsterile vacuum-driven Milliflip™ filter unit is designed to offer a convenient solution to quickly clarify samples, buffers and reagents prior to analysis.The ready-to-assemble, closed system of the Milliflip™ filtration unit offers an ergonomic design, robust filtration of up to 50 ml, maximizes recovery, saves time, and reduces contamination. There is no sample transfer needed as you can simply filter with a flip of your wrist.

      Utile?

  5. Why is the liquid flowing out the vacuum tubing line?

    1 risposta
    1. There are two recommendations:
      1. Confirm orientation: This is likely being used upside-down. See user manual for correct orientation.
      2. Make sure to use a trap with filtered line to prevent liquid from entering pump or vacuum set-up (i.e. Millex® FG 50mm Cat. SLFG05010)

      Utile?

  6. What is the maximum centrifugal speed of the conical tube?

    1 risposta
    1. 5000 x g (Fixed angle 23, 35, 45-degree rotors)

      Utile?

  7. Does Milliflip™ have other options for membrane material besides 0.45 µm Durapore® polyvinylidene fluoride (PVDF)?

    1 risposta
    1. Milliflip™ is currently only offered in 0.45 µm Durapore® polyvinylidene fluoride (PVDF). However, sterile versions of PES, Nylon and PVDF membranes are available in the Steriflip brand.

      Utile?

  8. What is the minimum volume that can be filtered?

    1 risposta
    1. Sample volume should be greater than 1-2 mL. Filter unit hold-up and tubes’ residual hold-up volume can be ~0.5 mL. It is best to have entire filter surface covered in liquid

      Utile?

  9. Can I sterilize the Milliflip™ Durapore HV filter?

    1 risposta
    1. Sterile version of the Durapore-HV filter can be ordered (Steriflip® HV filter Cat. SE1M003M00)

      Utile?

  10. Do I have to use vacuum pressure to filter my sample?

    1 risposta
    1. Yes, this is a vacuum type of device and processing is performed using vacuum pressure. Many types of vacuum sources may be used including pumps and house vacuum

      Utile?

1–10 di 17 domande  

Recensioni

Nessuna valutazione

Filtri attivi

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.