KR05A51TT1
Opticap® XL1 Polygard® CR
inlet connection diam. 1.5 in., pore size 5.0 μm, cartridge nominal length 1 in. (2.5 cm)
Sinonimo/i:
Opticap XL1 Polygard CR 5.0 μm 1-1/2 in. TC/TC
About This Item
Materiali
polypropylene
polypropylene housing
polypropylene support
polypropylene vent cap
silicone seal
Livello qualitativo
Conformità normativa
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
Produttore/marchio commerciale
Opticap®
Parametri
1.0 bar max. inlet pressure (15 psi) at 80 °C
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
4.8 bar max. differential pressure (70 psid) at 20 °C
5.5 bar max. inlet pressure (80 psi) at 25 °C
80 psig max. inlet pressure
Lunghezza
21.6 cm (8.5 in.)
Lunghezza nominale della cartuccia
1 in. (2.5 cm)
Diametro
10.7 cm (4.2 in.)
Diam. connessione ingresso
1.5 in.
Amp. ingresso/ uscita
21.6 cm (8.5 in.)
Diam. connessione uscita
1.5 in.
Impurezze
≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
Estraibili (gravimetria)
≤10 mg/capsule
Matrice
Polygard®-CR
Dimensione pori
5.0 μm nominal pore size
5.0 μm pore size
input
sample type liquid
Raccordi
inlet sanitary flange
38 mm (1 1/2 in.) inlet/outlet sanitary flange
outlet sanitary flange
Descrizione generale
The KR05A51TT1 Opticap® XL1Polygard® CR features a pore size of 5.0 μm. This single layer capsule filter has a sanitary flange inlet/outlet connection measuring 1.5 in. in diameter.
Opticap XL capsule filters eliminate the time and expense associated with assembling, cleaning, and validating stainless steel housings. The capsule patented design allows unparalleled thermal and hydraulic stress resistance, resulting in reliability, high confidence in the sterility process and improved cleanliness. The unique capsule design with Polygard® CR media minimizes hold-up volume and reduces production losses.
Caratteristiche e vantaggi
Confezionamento
Altre note
Nota sulla preparazione
3 autoclave cycles of 30 min @ 126 °C; not in-line steam sterilizable
Risultati analitici
Note legali
Esclusione di responsabilità
Certificati d'analisi (COA)
Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.