KPHLS1TTT1
Capsula Opticap® XLT con membrana Durapore® da 0,45 µm
Opticap® XLT 10, cartridge nominal length 14.8 in. (37.6 cm), filter diam. 4.2 in. (10.7 cm)
About This Item
Prodotti consigliati
Materiali
polyester support
polyethylene support
polypropylene filter
polypropylene housing
silicone seal
Livello qualitativo
Conformità normativa
FDA 21CFR177-182 (all component materials)
Sterilità
sterile; irradiated
Nome Commerciale
Opticap® XLT 10
Caratteristiche
hydrophilic
Produttore/marchio commerciale
Opticap®
Parametri
≤15.0 mL/min air diffusion at 3.9 bar (56 psig) and 23 °C (in water)
1 bar max. inlet pressure (15 psi) at 80 °C
2.1 bar max. differential pressure (30 psid) at 4-40 °C (Reverse:)
2.8 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
4.1 bar max. differential pressure (60 psid) at 25 °C (Forward:)
5.5 bar max. inlet pressure (80 psi) at 23 °C
80 psig max. inlet pressure
tecniche
bioburden reduction: suitable
Lunghezza nominale della cartuccia
14.8 in. (37.6 cm)
device L
37.6 cm (14.8 in.)
device size
10 in.
Diam. filtro
4.2 in. (10.7 cm)
filter filtration area
0.62 m2
Diam. connessione ingresso
1-1/2 in.
inlet to outlet width
37.6 cm (14.8 in.)
Diam. connessione uscita
1-1/2 in.
Impurezze
≤0.25 EU/mL bacterial endotoxins (LAL test, aqueous extraction)
<0.25 EU/mL bacterial endotoxins (LAL test, sample aqueous extraction)
Matrice
Durapore®
Dimensione pori
0.45 μm pore size
Punto di bolla
≥1930 mbar (28 psig), air with water at 23 °C
Raccordi
1/4 in. fitting (vent/drain hose barb with double O-ring seal)
(38 mm (1 1/2 in.) Sanitary Flange Inlet and Outlet)
Cerchi prodotti simili? Visita Guida al confronto tra prodotti
Descrizione generale
Nota sulla preparazione
Minimum sterilization up to 25 kGy. 3 autoclave cycles of 60min at 3°C; not in-line steam sterilizable
Risultati analitici
Altre note
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer installation section of Opticap® XL Capsules and Opticap® XLT Capsules user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations
Note legali
Not finding the right product?
Try our Motore di ricerca dei prodotti.
Certificati d'analisi (COA)
Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.