Passa al contenuto
Merck
Tutte le immagini(1)

Key Documents

KGW2A04HH3

Millipore

Polysep II 1.0/1.2 µm nominal, Opticap® XL Capsule

Opticap® XL 4, pore size 1.2/1.0 μm, cartridge nominal length 4 in. (10 cm), filter diam. 5.7 in. (14.5 cm)

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Codice UNSPSC:
23151806

Materiali

borosilicate glass fiber (BGF) membrane
mixed cellulose esters (MCE) membrane
polypropylene filter
polypropylene housing
polypropylene support
silicone seal

Livello qualitativo

Conformità normativa

FDA 21CFR177-182 (all component materials)

Sterilità

non-sterile

Compatibilità con la sterilizzazione

autoclavable compatible

Nome Commerciale

Opticap® XL 4

Caratteristiche

hydrophilic

Produttore/marchio commerciale

Opticap®

Parametri

1 bar max. inlet pressure (15 psi) at 80 °C
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
3.5 bar max. differential pressure (50 psid) at 25 °C
5.5 bar max. inlet pressure (80 psi) at 23 °C
80 psig max. inlet pressure

tecniche

prefiltration: suitable

Lunghezza nominale della cartuccia

4 in. (10 cm)

device L

19.6 cm (7.7 in.)

device size

4 in.

Diam. filtro

5.7 in. (14.5 cm)

filter filtration area

0.11 m2

Diam. connessione ingresso

9/16 in.

inlet to outlet width

19.6 cm (7.7 in.)

Diam. connessione uscita

9/16 in.

Impurezze

≤0.5 EU/mL bacterial endotoxins (LAL test, aqueous extraction)
<0.5 EU/mL bacterial endotoxins (LAL test, sample aqueous extraction)

Matrice

Polysep II

pore size

1.0/1.2 μm nominal pore size
1.2/1.0 μm pore size

Raccordi

(14 mm (9/16 in.) Hose Barb Inlet and Outlet)

Cerchi prodotti simili? Visita Guida al confronto tra prodotti

Descrizione generale

Device Configuration: Capsule

Caratteristiche e vantaggi

Double Layer

Confezionamento

Double Easy-Open bag

Nota sulla preparazione

Sterilization Method:
3 autoclave cycles of Sterilization Method: 30min at 121°C; not in-line steam sterilizable

This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21CFR210.3(b)(6).

Risultati analitici

Gravimetric Extractables: ≤ 85 mg per capsule after a 1200 mL flush and 24 hours in water at controlled room temperature.
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥ 2 L

Altre note

Directions for Use:

  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer first page of Visual Inspection Guide and introduction section of Mixed cellulose esters Tech Brief
  • Storage Statement: Please refer Mixed cellulose esters Tech Brief
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations

Note legali

OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany
Polysep is a trademark of Sigma-Aldrich Co. LLC

Non trovi il prodotto giusto?  

Prova il nostro Motore di ricerca dei prodotti.


Certificati d'analisi (COA)

Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.