17-10393
Rac1 Activation Magnetic Beads Pulldown Assay
Non-radioactive Rac1 Activation Assay Kit can be used to precipitate Rac1-GTP from cell lysates, & detection by a Rac1 specific monoclonal antibody.
Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali
About This Item
Prodotti consigliati
Livello qualitativo
Reattività contro le specie
rat, mouse, human
Produttore/marchio commerciale
Upstate®
tecniche
activity assay: suitable (G-protein activation)
affinity binding assay: suitable
N° accesso NCBI
N° accesso UniProt
Condizioni di spedizione
dry ice
Informazioni sul gene
human ... RAC1(5879)
Specificità
Predicted to cross-react with all mammalian species
Anti-Rac1, clone 23A8 (mouse monoclonal IgG2b): Human, mouse and rat, other species cross-reactivity unknown. Note: This antibody may be reused 3-5 times for immunoblot analysis. Add 0.05% sodium azide to the blocking buffer containing the diluted antibody. Do not use sodium azides with HRP
Anti-Rac1, clone 23A8 (mouse monoclonal IgG2b): Human, mouse and rat, other species cross-reactivity unknown. Note: This antibody may be reused 3-5 times for immunoblot analysis. Add 0.05% sodium azide to the blocking buffer containing the diluted antibody. Do not use sodium azides with HRP
Applicazioni
Non-radioactive Rac1 Activation Assay Kit can be used to precipitate Rac1-GTP from cell lysates, & detection by a Rac1 specific monoclonal antibody.
Research Category
Signaling
Signaling
Confezionamento
Kit capacity: 30 assays
Componenti
Rac1/Cdc42 Assay Reagent (Pak-1 PBD, Magnetic beads): 300 ug of Pak-1 PBD in 150 uL of glutathione magnetic beads, provided as a 50% beads slurry in PBS containing 50% glycerol for a final volume of 300 uL.
Anti-Rac1, clone 23A8: (Part No. 05-389) One vial containing 250 ug of purified IgG2akappa in 250 uL of storage buffer (0.1 M Tris-glycine, pH 7.4, 0.15 M NaCl, containing 0.05% sodium azide).
Mg2+ Lysis/Wash Buffer, 5X, (Part No. 20-168).Two vials, each vial contains 18 mL of 125 mM, HEPES, pH 7.5, 750 mM NaCl, 5% Igepal CA-630, 50mM MgCl2, 5 mM EDTA and 10% glycerol
100X GTPγS, 10mM (Cat.# 20-176) One vial containing 50 uL of 10 mM GTPγS, 100X stock, in sterile water. Non-hydrolyzable analog of GTP. Sufficient to label 5 mL of cell lysates
100X GDP, 100 mM, (Part No. 20-177). One vial containing 50 uL of 100 mM GDP, 100X stock, in sterile water. GDP, Guanosine 5’-Diphosphate, type I, for in vitro labeling of G-proteins in the inactive form. Sufficient to label 5ml of cell lysates.
Anti-Rac1, clone 23A8: (Part No. 05-389) One vial containing 250 ug of purified IgG2akappa in 250 uL of storage buffer (0.1 M Tris-glycine, pH 7.4, 0.15 M NaCl, containing 0.05% sodium azide).
Mg2+ Lysis/Wash Buffer, 5X, (Part No. 20-168).Two vials, each vial contains 18 mL of 125 mM, HEPES, pH 7.5, 750 mM NaCl, 5% Igepal CA-630, 50mM MgCl2, 5 mM EDTA and 10% glycerol
100X GTPγS, 10mM (Cat.# 20-176) One vial containing 50 uL of 10 mM GTPγS, 100X stock, in sterile water. Non-hydrolyzable analog of GTP. Sufficient to label 5 mL of cell lysates
100X GDP, 100 mM, (Part No. 20-177). One vial containing 50 uL of 100 mM GDP, 100X stock, in sterile water. GDP, Guanosine 5’-Diphosphate, type I, for in vitro labeling of G-proteins in the inactive form. Sufficient to label 5ml of cell lysates.
Qualità
Routinely evaluated by precipitating Rac-GTP from 3T3 cell lysates that had been loaded with GTPγS. The precipitated Rac-GTP was detected by immunoblot analysis using anti-Rac.
Linkage
Replaces: SGT425
Note legali
UPSTATE is a registered trademark of Merck KGaA, Darmstadt, Germany
Esclusione di responsabilità
Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
Avvertenze
Danger
Indicazioni di pericolo
Consigli di prudenza
Classi di pericolo
Aquatic Acute 1 - Aquatic Chronic 2 - Eye Dam. 1
Codice della classe di stoccaggio
10 - Combustible liquids
Certificati d'analisi (COA)
Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
EMBO reports, 19(7) (2018-05-26)
Integrin β3 is seen as a key anti-angiogenic target for cancer treatment due to its expression on neovasculature, but the role it plays in the process is complex; whether it is pro- or anti-angiogenic depends on the context in which
Cellular and molecular life sciences : CMLS, 79(2), 122-122 (2022-02-08)
Skeletal muscle demonstrates a high degree of regenerative capacity repeating the embryonic myogenic program under strict control. Rhabdomyosarcoma is the most common sarcoma in childhood and is characterized by impaired muscle differentiation. In this study, we observed that silencing the expression
The Journal of neuroscience : the official journal of the Society for Neuroscience, 39(25), 4959-4975 (2019-04-18)
Coiled-coil and C2 domain containing 1A (CC2D1A) is an evolutionarily conserved protein, originally identified as a nuclear factor-κB activator through a large-scale screen of human genes. Mutations in the human Cc2d1a gene result in autosomal recessive nonsyndromic intellectual disability. It
Oncotarget, 6(11), 8851-8874 (2015-04-11)
N-myc downstream regulated gene-1 (NDRG1) is a potent metastasis suppressor that plays a key role in regulating signaling pathways involved in mediating cancer cell invasion and migration, including those derived from prostate, colon, etc. However, the mechanisms and molecular targets
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.