Saltar al contenido
Merck

179124

Sigma-Aldrich

Acetona

Acetone

ACS reagent, ≥99.5%

Sinónimos:

2-propanona, Dimetil cetona

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización


About This Item

Fórmula lineal:
CH3COCH3
Número de CAS:
Peso molecular:
58.08
Beilstein/REAXYS Number:
635680
EC Number:
MDL number:
UNSPSC Code:
12352115
eCl@ss:
39021201
PubChem Substance ID:
NACRES:
NA.02
grade:
ACS reagent
assay:
≥99.5%
technique(s):
UV/Vis spectroscopy: suitable
bp:
56 °C/760 mmHg (lit.)
vapor pressure:
184 mmHg ( 20 °C)
En este momento no podemos mostrarle ni los precios ni la disponibilidad

grade

ACS reagent

Quality Level

agency

suitable for EPA 1613

vapor density

2 (vs air)

vapor pressure

184 mmHg ( 20 °C)

assay

≥99.5%

form

liquid

shelf life

Recommended retest period - 2 years

expl. lim.

13.2 %

technique(s)

UV/Vis spectroscopy: suitable

impurities

≤0.0003 meq/g Titr. acid
≤0.0006 meq/g Titr. base
≤0.002% aldehyde as formaldehyde
≤0.05% isopropanol
≤0.05% methanol
≤0.5% water

evapn. residue

≤0.001%

color

APHA: ≤10
clear

refractive index

n20/D 1.359 (lit.)

pH

5-6 (20 °C, 395 g/L)

bp

56 °C/760 mmHg (lit.)

mp

−94 °C (lit.)

density

0.791 g/mL at 25 °C (lit.)

format

neat

storage temp.

room temp

SMILES string

CC(C)=O

InChI

1S/C3H6O/c1-3(2)4/h1-2H3

InChI key

CSCPPACGZOOCGX-UHFFFAOYSA-N

¿Está buscando productos similares? Visita Guía de comparación de productos

General description

La acetona es un disolvente orgánico, aprótico, polar. Es un líquido incoloro y muy volátil. Se utiliza comúnmente en síntesis orgánicas como disolvente o unidad estructural en las industrias farmacéutica y de cuidado personal. Este grado cumple las requisitos del ACS, lo que la hace ideal para una amplia gama de aplicaciones analíticas.

Application

  • Se utiliza como disolvente o unidad estructural en síntesis orgánica, como en las reacciones SN2 y la oxidación de Jones
  • Fase móvil en cromatografía en capa fina (TLC)
  • Se utiliza como disolvente en sistemas de suministro de moléculas químicas en las industrias farmacéutica y cosmética
  • Para limpieza
La intensidad de luminiscencia de la acetona depende de los componentes de la disolución . La absorción de luz ultravioleta por la acetona tiene como consecuencia su fotólisis y la producción de radiales .

Features and Benefits

Los disolventes ACS cumplen o superan los altos estándares de la American Chemical Society (ACS), con especificaciones analíticas especializadas para cada compuesto. Según la American Chemical Society, la calidad para reactivo ACS implica que es una sustancia de suficiente pureza como para utilizarse en la mayoría de los análisis o reacciones químicos.

Other Notes

Los recipientes Pure-Pac® II precisan el acoplador Micromatic MacroValve, Z560723, para la dispensación de los disolventes.

Legal Information

Pure-Pac is a registered trademark of Merck KGaA, Darmstadt, Germany

greener alternative product

Referencia del producto
Descripción
Precios

pictograms

FlameExclamation mark

signalword

Danger

Hazard Classifications

Eye Irrit. 2 - Flam. Liq. 2 - STOT SE 3

target_organs

Central nervous system

supp_hazards

Storage Class

3 - Flammable liquids

wgk_germany

WGK 1

flash_point_f

1.4 °F - closed cup

flash_point_c

-17.0 °C - closed cup


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Los clientes también vieron

Preparation of 1,2-diketones: oxidation of alkynes by potassium permanganate in aqueous acetone
Srinivasan NS and Donald GL
The Journal of Organic Chemistry, 44(9), 1574-1574 (1979)
Aldol condensation of acetone over layered double hydroxides of the meixnerite type.
Tichit D, et al.
Applied Clay Science, 13(5), 401-415 (1998)
An investigation on photocatalytic activities of mixed TiO2-rare earth oxides for the oxidation of acetone in air.
Lin J and Jimmy CY.
Journal of Photochemistry and Photobiology A: Chemistry, 116(1), 63-67 (1998)
Oleksiy Krupin et al.
Optics express, 21(1), 698-709 (2013-02-08)
Straight long-range surface plasmon waveguides are demonstrated as biosensors for the detection of cells, proteins and changes in the bulk refractive index of solutions. The sensors consist of 5 μm wide 22 nm thick Au stripes embedded in polymer (CYTOP™)
Juan A López-Ráez et al.
Plant science : an international journal of experimental plant biology, 230, 59-69 (2014-12-07)
Apocarotenoids are a class of compounds that play important roles in nature. In recent years, a prominent role for these compounds in arbuscular mycorrhizal (AM) symbiosis has been shown. They are derived from carotenoids by the action of the carotenoid

Artículos

Substances are said to be miscible in one another if they dissolve to form a uniform solution. Bookmark or download our miscibility table for common lab solvents.

Substances are said to be miscible in one another if they dissolve to form a uniform solution. Bookmark or download our miscibility table for common lab solvents.

Se dice que las sustancias son miscibles entre sí si se disuelven hasta formar una disolución uniforme. Marque o descargue nuestra tabla de miscibilidad para los disolventes comunes del laboratorio.

Se dice que las sustancias son miscibles entre sí si se disuelven hasta formar una disolución uniforme. Marque o descargue nuestra tabla de miscibilidad para los disolventes comunes del laboratorio.

Ver todo

Protocolos

Derived from procedure SSPHYT02. Includes template updates to current SOP specifications and incorporation of notes into the procedure.

Derived from procedure SSPHYT02. Includes template updates to current SOP specifications and incorporation of notes into the procedure.

Derived from procedure SSPHYT02. Includes template updates to current SOP specifications and incorporation of notes into the procedure.

Derived from procedure SSPHYT02. Includes template updates to current SOP specifications and incorporation of notes into the procedure.

Questions

1–3 of 3 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  3. If the can does not include a plastic Flex Spout, what is the pour spout adapter for Item # 179124-18L-CS, 673811-18L-CS, and 178918-18L-CS?

    1 answer
    1. The pour spout adapter for Item # 179124-18L-CS, 673811-18L-CS, and 178918-18L-CS is Item # Z557757-1EA. The adapter can be used for pouring directly from the can or adapting a hand pump.

      Helpful?

Reviews

Active Filters

  1. 3 Ratings-Only Reviews

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico