跳转至内容
Merck
  • Multi-residue pesticide analysis (gas chromatography-tandem mass spectrometry detection)-Improvement of the quick, easy, cheap, effective, rugged, and safe method for dried fruits and fat-rich cereals-Benefit and limit of a standardized apple purée calibration (screening).

Multi-residue pesticide analysis (gas chromatography-tandem mass spectrometry detection)-Improvement of the quick, easy, cheap, effective, rugged, and safe method for dried fruits and fat-rich cereals-Benefit and limit of a standardized apple purée calibration (screening).

Journal of chromatography. A (2015-06-06)
Claudia Rasche, Britta Fournes, Uwe Dirks, Karl Speer
摘要

Some steps of the QuEChERS method for the analysis of pesticides with GC-MS/MS in cereals and dried fruits were improved or simplified. For the latter, a mixing vessel with stator-rotor-system proved to be advantageous. The extraction procedure of dried fruits is much easier and safer than the Ultra Turrax and results in excellent validation data at a concentration level of 0.01mg/kg (116 of 118 analytes with recoveries in the range of 70-120%, 117 of 118 analytes with RSD <20%). After qualifying problematic lipophilic pesticides in fat-rich cereals (fat content >7%), predominantly organochlorines showed recoveries of <70% in quantification when the standard QuEChERS method with water was used. A second extraction was carried out analogous to the QuEChERS method, however, without the addition of water. With this simple modification, the problematic lipophilic pesticides, which had been strongly affected by the fat content of the commodities, could be determined with recoveries above 70% even at a concentration level of 0.01mg/kg. Moreover, a GC-MS/MS screening method for 120 pesticides at a concentration level of 0.01mg/kg was established by employing analyte protectants (ethylglycerol, gulonolactone, and sorbitol). The use of only one standardized calibration, made of an apple purée extract in combination with analyte protectants, allowed for a qualitative and quantitative analysis of 120 pesticides in different matrix extracts (tomato, red pepper, sour cherries, dried apples, black currant powder, raisins, wheat flour, rolled oats, wheat germ). The analyte protectants leveled the differences in the matrix-induced protection effect of the analyzed extracts over a wide range. The majority of the pesticides were analyzed with good analytical results (recoveries in the range of 70-120% and RSD <20%).

材料
货号
品牌
产品描述

Sigma-Aldrich
D -山梨醇, ≥98% (GC)
Sigma-Aldrich
乙腈, anhydrous, 99.8%
Sigma-Aldrich
D -山梨醇, BioUltra, ≥99.0% (HPLC)
Sigma-Aldrich
D -山梨醇, 99% (GC)
Sigma-Aldrich
D -山梨醇, ≥98% (GC), for molecular biology
Sigma-Aldrich
3-乙氧基-1,2-丙二醇, 98%
Sigma-Aldrich
磷酸三苯酯, ≥99%
Sigma-Aldrich
蒽, ReagentPlus®, 99%
Sigma-Aldrich
D -山梨醇, ≥98% (GC), BioReagent, suitable for cell culture, suitable for plant cell culture
Sigma-Aldrich
蒽, reagent grade, 97%
Sigma-Aldrich
山梨醇 F 液 溶液, 70 wt. % in H2O, Contains mainly D-sorbitol with lesser amounts of other hydrogenated oligosaccharides
Sigma-Aldrich
乙腈, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
D -山梨醇, FCC, FG
Supelco
乙腈, HPLC grade, ≥99.93%
Sigma-Aldrich
D -山梨醇, ≥98% (GC), BioXtra
Sigma-Aldrich
乙腈, ≥99.8%, suitable for HPLC
Sigma-Aldrich
乙腈, HPLC Plus, ≥99.9%, poly-coated bottles
Sigma-Aldrich
蒽, suitable for scintillation, ≥99.0% (GC)
Sigma-Aldrich
乙腈 溶液, contains 0.1 % (v/v) trifluoroacetic acid, suitable for HPLC
Sigma-Aldrich
乙腈, ≥99.8%, for residue analysis, JIS 300
Sigma-Aldrich
乙腈, JIS special grade, ≥99.5%
Sigma-Aldrich
磷酸三苯酯溶液, NMR reference standard, 0.0485 M in acetone-d6 (99.9 atom % D)
Sigma-Aldrich
蒽, sublimed grade, ≥99%
Sigma-Aldrich
磷酸三苯酯 溶液, NMR reference standard, 0.0485 M in acetone-d6 (99.9 atom % D), NMR tube size 10 mm × 8 in.
Sigma-Aldrich
乙腈, ≥99.5%, ACS reagent
Sigma-Aldrich
乙腈 溶液, contains 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
乙腈, SAJ first grade, ≥99.0%
Sigma-Aldrich
乙腈, for chromatography
Sigma-Aldrich
乙腈, ≥99.8%, for residue analysis, JIS 1000
Sigma-Aldrich
磷酸三苯酯 溶液, NMR reference standard, 0.0485 M in acetone-d6 (99.9 atom % D), NMR tube size 3 mm × 8 in.