跳转至内容
Merck
  • Solid-phase extraction coupled with ultra high performance liquid chromatography and electrospray tandem mass spectrometry for the highly sensitive determination of five iodinated X-ray contrast media in environmental water samples.

Solid-phase extraction coupled with ultra high performance liquid chromatography and electrospray tandem mass spectrometry for the highly sensitive determination of five iodinated X-ray contrast media in environmental water samples.

Journal of separation science (2015-04-03)
Xia Li, Junjian Hu, Daqiang Yin, Xialin Hu
摘要

A highly sensitive method based on solid-phase extraction and ultra high performance liquid chromatography with electrospray tandem mass spectrometry has been developed for simultaneous determination of five iodinated X-ray contrast media in environmental water samples. Various solid-phase extraction cartridges have been evaluated and a combination of LiChrolute EN and ENVI-Carb solid phase extraction cartridges was selected for sample enrichment. The method was comprehensively validated on ground water, tap water, surface water, drinking water, and waste water by the conventional procedures: linearity, method detection limits, accuracy and precision, matrix effects. Good linearity (R(2) > 0.999), low detection limits (0.4-8.1 ng/L), satisfactory recoveries (55.1-109.5%) and precision (0.8-10.0% for intra-day precisions and 0.6-16.5% for inter-day precisions) were obtained for all the target compounds. Iopamidol, iohexol, and diatrizoate in some matrices were affected by matrix effects, which were slightly eased by using the isotope-labeled internal standard. The developed method was successfully applied for real samples collected in Shanghai, China, with detected concentrations up to 2200 ± 200 and 9000 ± 1000 ng/L for iohexol and iopamidol, respectively.

材料
货号
品牌
产品描述

Sigma-Aldrich
乙腈, anhydrous, 99.8%
Sigma-Aldrich
碘海醇, nonionic density gradient medium
Sigma-Aldrich
甲醇, anhydrous, 99.8%
Sigma-Aldrich
甲醇, JIS special grade, ≥99.8%
Sigma-Aldrich
甲醇, SAJ first grade, ≥99.5%
Sigma-Aldrich
乙腈, HPLC Plus, ≥99.9%, poly-coated bottles
Sigma-Aldrich
乙腈, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
乙腈 溶液, contains 0.1 % (v/v) formic acid, suitable for HPLC
Supelco
乙腈, HPLC grade, ≥99.93%
Sigma-Aldrich
甲醇, SAJ special grade
Sigma-Aldrich
甲醇, suitable for HPLC
Sigma-Aldrich
乙腈, ≥99.8%, suitable for HPLC
Sigma-Aldrich
乙腈 溶液, contains 0.1 % (v/v) trifluoroacetic acid, suitable for HPLC
Supelco
Supel QuE, PSA/ENVI-Carb Tube 2, pk of 50, suitable for EN 15662:2008 per BS, centrifuge tube volume 15 mL , Shaker Compatible
Sigma-Aldrich
甲醇, suitable for HPLC, gradient grade, 99.93%
Supelco
Supel QuE, PSA/ENVI-Carb (EN) Cleanup Tube 2, pack of 100, suitable for EN 15662:2008 per BS
Sigma-Aldrich
甲醇, NMR reference standard
Sigma-Aldrich
乙腈, ≥99.8%, for residue analysis, JIS 300
Supelco
Supel QuE, PSA/ENVI-Carb Tube 1, pk of 50, suitable for EN 15662:2008 per BS, centrifuge tube volume 15 mL , Shaker Compatible
Sigma-Aldrich
乙腈, JIS special grade, ≥99.5%
Sigma-Aldrich
乙腈, ≥99.5%, ACS reagent
Sigma-Aldrich
甲醇 溶液, NMR reference standard, 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Supelco
Supel QuE, PSA/C18/ENVI-Carb Tube, pk of 50, AOAC® 2007.01, centrifuge tube volume 15 mL , Shaker Compatible
Sigma-Aldrich
甲醇-12C, 99.95 atom % 12C
Supelco
甲醇 溶液, contains 0.10 % (v/v) formic acid, UHPLC, suitable for mass spectrometry (MS), ≥99.5%
Sigma-Aldrich
甲醇, JIS 300, ≥99.8%, for residue analysis
Supelco
Supel QuE, PSA/C18/ENVI-Carb Tube, pack of 100, AOAC® 2007.01
Supelco
Supel QuE, PSA/ENVI-Carb (EN) Cleanup Tube 1, pack of 100, suitable for EN 15662:2008 per BS
Sigma-Aldrich
甲醇, HPLC Plus, ≥99.9%, poly-coated bottles
Sigma-Aldrich
乙腈, SAJ first grade, ≥99.0%