A-LMPAKMM
Activation Kit For Multiplex Microspheres
Synonyme(s) :
AnteoTech Microsphere Activation Kit
About This Item
Produits recommandés
Utilisation
10 reactions
Disponibilité
not available in Japan
Température de stockage
2-8°C
Catégories apparentées
Description générale
- Binding difficult antibodies and antigens to microspheres
- Complex protocols for inexperienced users
- Lengthy microsphere and protein preparation times prior to protein coupling
- Reproducibility between batches of protein coupled microspheres
- Limited storage of ready-to-couple microspheres
From these findings, they developed the AnteoBind™ Activation Kit For Multiplex Microspheres that is for use with the Luminex xMAP® system and contains the patented AnteoBind Activation Reagent.
With this Activation Kit, you can couple multiple antibodies without extra optimization for each, saving assay development time and reducing the barriers of assay transfer between diverse platforms.
AnteoBind is water based and replaces the dry chemicals you would use with the EDC method. Using AnteoBind instead of NHS/EDC chemistry can save up to 3-4 hours of lab time. Experiments have shown increased stability and functionality for antibodies and a decreased background. AnteoBind improves reproducibility between experiments by providing uniformity between surfaces. You can store your AnteoBind activated microspheres for up to 1 year.
POSTER: A Novel User Friendly Chemistry to Couple Antibodies and Challenging Proteins to Luminex MagPlex Microspheres
Application
Caractéristiques et avantages
- Water based AnteoBind™ activation and coupling reagent for microspheres
- Fast assay development time making it easy to move your ELISA assay to the Luminex xMAP® system
- Compatible with both Luminex MagPlex® and MicroPlex® microspheres
- Test problematic proteins on xMAP, including those cited as not suitable for the system
- An alternative to traditional chemistries such as NHS/EDC methods with an easier to use AnteoBind protocol
- Ease of use, simply pipette AnteoBind Reagent to your chosen microspheres to activate
- Reduce reagent preparation time by 3-4 hours
- Increase antibody functionality
- Low background noise
- High reproducibility between experiments
Informations légales
Composants de kit seuls
- Mix&Go Activation Reagent
- Coupling Buffer
- Storage Buffer
- Low Binding Microcentrifuge Tubes
Mention d'avertissement
Warning
Mentions de danger
Conseils de prudence
Classification des risques
Aquatic Chronic 2 - Skin Sens. 1
Code de la classe de stockage
12 - Non Combustible Liquids
Point d'éclair (°F)
Not applicable
Point d'éclair (°C)
Not applicable
Faites votre choix parmi les versions les plus récentes :
Certificats d'analyse (COA)
Désolés, nous n'avons pas de COA pour ce produit disponible en ligne pour le moment.
Si vous avez besoin d'assistance, veuillez contacter Service Clients
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..
Contacter notre Service technique