Accéder au contenu
Merck
Toutes les photos(1)

Key Documents

87212

Sigma-Aldrich

Trimethyl-tetradecylammonium chloride

≥98.0% (AT)

Synonyme(s) :

Tetradecyltrimethylammonium chloride

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Formule linéaire :
CH3(CH2)13N(Cl)(CH3)3
Numéro CAS:
Poids moléculaire :
291.94
Numéro Beilstein :
3916572
Numéro CE :
Numéro MDL:
Code UNSPSC :
12352116
ID de substance PubChem :
Nomenclature NACRES :
NA.22

Niveau de qualité

Pureté

≥98.0% (AT)

Forme

powder

Pf

~250 °C (dec.)

Chaîne SMILES 

[Cl-].CCCCCCCCCCCCCC[N+](C)(C)C

InChI

1S/C17H38N.ClH/c1-5-6-7-8-9-10-11-12-13-14-15-16-17-18(2,3)4;/h5-17H2,1-4H3;1H/q+1;/p-1

Clé InChI

CEYYIKYYFSTQRU-UHFFFAOYSA-M

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Catégories apparentées

Pictogrammes

Exclamation mark

Mention d'avertissement

Warning

Mentions de danger

Classification des risques

Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3

Organes cibles

Respiratory system

Code de la classe de stockage

11 - Combustible Solids

Classe de danger pour l'eau (WGK)

WGK 3

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable

Équipement de protection individuelle

dust mask type N95 (US), Eyeshields, Gloves


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Vous ne trouvez pas la bonne version ?

Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Hayat M Marafie et al.
Talanta, 91, 26-32 (2012-03-01)
Two conventional plastic membrane electrodes that are selective for the tetradecyltrimethylammonium cation (TTA) have been prepared. The ion exchangers of these sensors were the ion associate, TTA-PT, and the ion aggregate, TTA-PSS, where PT and PSS are phosphotungstate and polystyrene
Dulan B Gunasekara et al.
Electrophoresis, 32(8), 832-837 (2011-03-26)
The combination of microchip electrophoresis with amperometric detection leads to a number of analytical challenges that are associated with isolating the detector from the high voltages used for the separation. While methods such as end-channel alignment and the use of
Yuri Borodko et al.
Langmuir : the ACS journal of surfaces and colloids, 25(12), 6665-6671 (2009-04-29)
The vibrational spectra of platinum nanoparticles (12 nm) capped with tetradecyltrimethylammonium bromide, C(14)TAB, were investigated by Fourier transform infrared (FTIR) spectroscopy. We have shown that the thermal decay of Pt-C(14)TAB nanoparticles in N(2), H(2), and O(2) atmospheres leads to the
Dawei Fan et al.
Journal of colloid and interface science, 333(2), 757-763 (2009-02-24)
Phase stability of two nanometer-scale Keplerate-type polyoxomolybdates, (NH(4))(42)[Mo(VI)(72)Mo(V)(60)O(372)(CH(3)COO)(30)(H(2)O)(72)]300H(2)O10CH(3)COONH(4) ({Mo(132)}) and Mo(VI)(72)Fe(III)(30)O(252)L(102)ca. 180H(2)O with L=H(2)O/CH(3)COO(-)/Mo(2)O(n-)(8/9) ({Mo(72)Fe(30)}), can be easily achieved by controlling the concentration of a cationic surfactant, tetradecyltrimethylammonium bromide (TTABr), in aqueous solution. Precipitates and floccules were observed when the
Aline Delbos et al.
Physical review. E, Statistical, nonlinear, and soft matter physics, 84(1 Pt 1), 011404-011404 (2011-08-27)
We investigate experimentally the behavior of liquid foams pumped at a given flow rate through a single pore, in the situation where the pore diameter is smaller than the bubble diameter. Results reveal that foam invasion can be observed only

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique