Saltar al contenido
Merck

33824

Supelco

Pentadecafluorooctanoic acid

analytical standard

Sinónimos:

PFAS, PFOA, Perfluorocaprylic acid, Perfluorooctanoic acid

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización

Seleccione un Tamaño

100 MG
113,00 €

113,00 €


Póngase en contacto con nuestro Servicio de Atención al Cliente para disponibilidad

Solicitar un pedido a granel

Seleccione un Tamaño

Cambiar Vistas
100 MG
113,00 €

About This Item

Fórmula lineal:
CF3(CF2)6COOH
Número de CAS:
Peso molecular:
414.07
Beilstein:
1809678
Número CE:
Número MDL:
Código UNSPSC:
85151701
ID de la sustancia en PubChem:
NACRES:
NA.24

113,00 €


Póngase en contacto con nuestro Servicio de Atención al Cliente para disponibilidad

Solicitar un pedido a granel

grado

analytical standard

Nivel de calidad

Agency

suitable for ASTM® 7968
suitable for ASTM® 7979
suitable for DIN 38407-42
suitable for EPA 1633
suitable for EPA 533
suitable for EPA 537.1
suitable for EPA 8327
suitable for EPA ACB B21-02
suitable for EPA ACB B23-05b
suitable for EPA OTM-45
suitable for GB 31604.35-2016
suitable for GB 5009.253-2016
suitable for ISO 21675 2019
suitable for ISO 25101

cumplimiento norm.

suitable for FDA C-010.02

caducidad

limited shelf life, expiry date on the label

técnicas

HPLC: suitable
gas chromatography (GC): suitable

bp

189 °C/736 mmHg (lit.)

mp

55-56 °C (lit.)

cadena SMILES

OC(=O)C(F)(F)C(F)(F)C(F)(F)C(F)(F)C(F)(F)C(F)(F)C(F)(F)F

aplicaciones

PFAS testing
cleaning products
cosmetics
environmental
food and beverages
personal care

Formato

neat

InChI

1S/C8HF15O2/c9-2(10,1(24)25)3(11,12)4(13,14)5(15,16)6(17,18)7(19,20)8(21,22)23/h(H,24,25)

Clave InChI

SNGREZUHAYWORS-UHFFFAOYSA-N

¿Está buscando productos similares? Visita Guía de comparación de productos

Descripción general

Pentadecafluorooctanoic acid is a perfluoroalkyl carboxylic acid,[1] which is primarily used as an ion pair reagent.[2]

Aplicación

Pentadecafluorooctanoic acid may be used as an ion pair reagent in the determination of underivatized amino acids in fermentation media using liquid chromatography coupled with tandem mass spectrometry (LC-MS-MS).[2]
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

Información legal

ASTM is a registered trademark of American Society for Testing and Materials

Palabra de señalización

Danger

Clasificaciones de peligro

Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Carc. 2 - Eye Dam. 1 - Lact. - Repr. 1B - Skin Corr. 1C - STOT RE 1

Órganos de actuación

Liver

Código de clase de almacenamiento

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

Clase de riesgo para el agua (WGK)

WGK 3

Equipo de protección personal

Eyeshields, Faceshields, Gloves, type P3 (EN 143) respirator cartridges


Listados normativos

Los listados normativos se proporcionan para los productos químicos principalmente. Para los productos no químicos sólo se puede proporcionar información limitada. Si no hay ninguna entrada, significa que ninguno de los componentes está en la lista. Es obligación del usuario garantizar el uso seguro y legal del producto.

EU REACH SVHC Candidate List

CAS No.

EU REACH Annex XVII (Restriction List)

CAS No.

Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

Ion-pair reversed-phase liquid chromatography for determination of polar underivatized amino acids using perfluorinated carboxylic acids as ion pairing agent.
Petritis NK, et al.
Journal of Chromatography A, 833(2), 147-155 (1999)
Rapid determination of underivatized pyroglutamic acid, glutamic acid, glutamine and other relevant amino acids in fermentation media by LC-MS-MS.
Qu J, et al.
Analyst, 127(1), 66-69 (2002)
Anne Vested et al.
Environmental health perspectives, 121(4), 453-458 (2013-01-31)
Perfluorinated alkyl acids (PFAAs), persistent chemicals with unique water-, dirt-, and oil-repellent properties, are suspected of having endocrine-disrupting activity. The PFAA compounds perfluorooctanoic acid (PFOA) and perfluorooctane sulfonic acid (PFOS) are found globally in humans; because they readily cross the
A K Rosenmai et al.
Toxicology and applied pharmacology, 266(1), 132-142 (2012-11-13)
Polyfluoroalkyl phosphate surfactants (PAPS) are widely used in food contact materials (FCMs) of paper and board and have recently been detected in 57% of investigated materials. Human exposure occurs as PAPS have been measured in blood; however knowledge is lacking
Mei-Huei Chen et al.
Epidemiology (Cambridge, Mass.), 24(6), 800-808 (2013-09-17)
Epidemiologic data regarding the potential neurotoxicity of perfluorinated compounds (PFCs) are inconclusive. We investigated the associations between in utero exposure to perfluorooctanoic acid (PFOA) and perfluorooctyl sulfonate (PFOS) and early childhood neurodevelopment. We recruited 239 mother-infant pairs in northern Taiwan

Artículos

Liquid Chromatography–Mass Spectrometry (LC-MS) separation of 33 PFAS (Per- and poly-fluoroalkyl substances) using a superficially porous silica particles (SPP) based Ascentis® Express C18 column.

Discover an LC-MS/MS method for the analysis of 16 per- and polyfluoroalkyl compounds (PFAS) in milk using QuEChERS extraction technique following FDA C-010.02 guidelines.

Sensitive PFAS testing can be performed with ultrapure water from a Milli-Q® IQ 7 system, which eliminates detectable PFAS for reliable LC-MS/MS results. See the science, see the proof.

Find more about the analysis of 16 PFAS in salmon via QuEChERS extraction and LC-MS/MS characterization following FDA Method C-010.02.

Preguntas

1–2 de 2 Preguntas  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 respuesta
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      ¿Le ha resultado útil?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 respuesta
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      ¿Le ha resultado útil?

Revisiones

Sin puntuación

Filtros activos

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico