Seleccione un Tamaño
| Talla/SKU | Disponibilidad | Precio |
|---|---|---|
3 ea |
Acerca de este artículo
No se puede adquirir este artículo como usuario invitado. Para más información, póngase en contacto con nosotros en +34 912 158 016o
.Nombre del producto
Millipore Express® SHF, Cápsula Opticap® XL, Chemistry: Hydrophilic Polyethersulfone (PES) Inlet: 3/4 in. Sanitary Flange Outlet: 3/4 in. Sanitary Flange Max Operating Pressure: 80 psi @ 25 °C
Quality Segment
material
polyethersulfone , polyethylene support, polypropylene (gamma-stable), polypropylene housing, polypropylene vent cap, polysulfone , silicone seal
reg. compliance
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
sterility
non-sterile
sterilization compatibility
gamma compatible
product line
Opticap® XL 600
feature
hydrophilic
manufacturer/tradename
Millipore Express®
parameter
≤5.8 mL/min air diffusion at 2.8 bar (40 psig) and 23 °C (in water), 1.0 bar max. differential pressure (15 psid) at 80 °C (Forward), 1.0 bar max. inlet pressure (15 psi) at 80 °C, 100 psi max. differential pressure (6.9 bar) (intermittent), 2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent), 2.75 bar max. inlet pressure (40 psi) at 60 °C, 25 °C max. inlet temp., 5.5 bar max. differential pressure (80 psid) at 25 °C (Forward), 5.5 bar max. inlet pressure (80 psi) at 23 °C, 6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent), 6.9 bar max. inlet pressure (100 psi) at 23 °C (intermittent), 80 psi max. differential pressure (5.5 bar) (continuous), 80 psig max. inlet pressure
technique(s)
sterile filtration: suitable
L
16.5 cm (6.5 in.)
W
2.2 in.
cartridge nominal length
6.5 in. (16.5 cm)
diam.
5.6 cm (2.2 in.)
filtration area
0.0971 m2 (1.05 ft2)
inlet connection diam.
3/4 in.
inlet to outlet W
16.5 cm (6.5 in.)
outlet connection diam.
3/4 in.
impurities
≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction), <0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
matrix
Millipore Express® SHF
pore size
0.2 μm pore size
bubble point
≥4000 mbar (58 psig), air with water at 23 °C
fitting
1/4 in. drain/vent hose barb (with double O-ring seal), inlet sanitary flange, outlet sanitary flange, (19 mm (3/4 in.) Sanitary Flange Inlet and Outlet)
General description
Packaging
Preparation Note
Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
Analysis Note
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
After sterilization and a controlled water flush of 3.0 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
Other Notes
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Legal Information
Disclaimer
1 of 1
Este artículo | |||
|---|---|---|---|
| description Chemistry: Hydrophilic Polyethersulfone (PES) Inlet: 3/4 in. Sanitary Flange Outlet: 3/4 in. Sanitary Flange Max Operating Pressure: 80 psi @ 25 °C | description Chemistry: Hydrophilic Polyethersulfone (PES) Inlet: 3/4 in. Sanitary Flange Outlet: 3/4 in. Sanitary Flange Max Operating Pressure: 80 psi @ 25 °C | description Chemistry: Hydrophilic Polyethersulfone (PES) Inlet: 9/16 in. Hose Barb Outlet: 9/16 in. Hose Barb Max Operating Pressure: 80 psi @ 25 °C | description Chemistry: Hydrophilic Polyethersulfone (PES) Inlet: 3/4 in. Sanitary Flange Outlet: 3/4 in. Sanitary Flange Max Operating Pressure: 80 psi @ 25 °C |
| pore size 0.2 μm pore size | pore size 0.2 μm | pore size 0.2 μm pore size | pore size 0.2 μm pore size |
| filtration area 970 cm2 | filtration area 970 cm2 | filtration area 970 cm2 | filtration area 480 cm2 |
| technique(s) sterile filtration: suitable | technique(s) sterile filtration: suitable | technique(s) sterile filtration: suitable | technique(s) sterile filtration: suitable |
| product line Opticap® XL 600 | product line Opticap® XL 600 | product line Opticap® XL 600 | product line Opticap® XL 3 |
| matrix Millipore Express® SHF | matrix Millipore Express® SHF | matrix Millipore Express® SHF | matrix Millipore Express® SHF |
| manufacturer/tradename Millipore Express® | manufacturer/tradename Millipore Express® | manufacturer/tradename Millipore Express® | manufacturer/tradename Millipore Express® |
Still not finding the right product?
Explore all of our products under Millipore Express® SHF, Cápsula Opticap® XL
Cumpla las GMP con el programa Emprove®.
Acelere la cualificación, mantenga la conformidad y ahorre tiempo con Emprove® Dossiers.
Nota: será redirigido a EmproveSuite.com. Su nombre de usuario y contraseña son independientes de SigmaAldrich.com y pueden diferir.
Regístrese gratis y acceda a Emprove® Dossiers en cuestión de minutos. Actualice su plan de suscripción para desbloquear contenidos avanzados y personalizados en la Emprove® Suite
¿No encuentra lo que busca? Visite la página de ayuda del programa Emprove®..
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
¿Le resulta difícil encontrar su producto o lote/número de lote?
Cómo encontrar el número de producto
Las referencias de los producto se combinan con los tamaños de envase y las cantidades cuando se muestran en la página web, por ejemplo: T1503-25G. Asegúrese de introducir el número de producto ÚNICAMENTE en el campo del Número de producto (ejemplo: T1503).
Ejemplo:
Otros ejemplos
705578-5MG-PW
PL860-CGA/SHF-1EA
MMYOMAG-74K-13
1000309185
introducir como 1.000309185)
¿Tienes problemas? Siéntase libre de contactar Servicio técnico para asistencia