Saltar al contenido
Merck

326380

Sigma-Aldrich

Cobalt

foil, thickness 0.1 mm, ≥99.99%

Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización

Seleccione un Tamaño

8.8 G
1890,00 €

1890,00 €


Póngase en contacto con nuestro Servicio de Atención al Cliente para disponibilidad

Solicitar un pedido a granel

Seleccione un Tamaño

Cambiar Vistas
8.8 G
1890,00 €

About This Item

Fórmula empírica (notación de Hill):
Co
Número de CAS:
Peso molecular:
58.93
Número CE:
Número MDL:
Código UNSPSC:
12141710
ID de la sustancia en PubChem:
NACRES:
NA.23

1890,00 €


Póngase en contacto con nuestro Servicio de Atención al Cliente para disponibilidad

Solicitar un pedido a granel

Ensayo

≥99.99%

Formulario

foil

resistividad

6.24 μΩ-cm, 20°C

grosor

0.1 mm

bp

2900 °C (lit.)

densidad

8.9 g/mL at 25 °C (lit.)

cadena SMILES

[Co]

InChI

1S/Co

Clave InChI

GUTLYIVDDKVIGB-UHFFFAOYSA-N

¿Está buscando productos similares? Visita Guía de comparación de productos

sustituido por

Referencia del producto
Descripción
Precios

Pictogramas

Health hazardExclamation mark

Palabra de señalización

Danger

Clasificaciones de peligro

Acute Tox. 4 Oral - Aquatic Chronic 3 - Carc. 1B - Eye Irrit. 2 - Muta. 2 - Repr. 1A - Resp. Sens. 1 - Skin Sens. 1

Código de clase de almacenamiento

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

Clase de riesgo para el agua (WGK)

WGK 3

Punto de inflamabilidad (°F)

Not applicable

Punto de inflamabilidad (°C)

Not applicable

Equipo de protección personal

dust mask type N95 (US), Eyeshields, Faceshields, Gloves


Listados normativos

Los listados normativos se proporcionan para los productos químicos principalmente. Para los productos no químicos sólo se puede proporcionar información limitada. Si no hay ninguna entrada, significa que ninguno de los componentes está en la lista. Es obligación del usuario garantizar el uso seguro y legal del producto.

EU REACH Annex XVII (Restriction List)

CAS No.

Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

S Perconti et al.
Journal of biological regulators and homeostatic agents, 27(2), 443-454 (2013-07-09)
Size-dependent characteristics of novel engineered nanomaterials might result in unforeseen biological responses and toxicity. To address this issue, we used cDNA microarray analysis (13443 genes) coupled with bioinformatics and functional gene annotation studies to investigate the transcriptional profiles of Balb/3T3
D W Su et al.
Journal of nanoscience and nanotechnology, 13(5), 3354-3359 (2013-07-19)
Highly ordered mesoporous Co3O4 nanostructures were prepared using SBA-15 silica as hard templates. The mesoporous structures were characterized by X-ray diffraction, high resolution transmission electron microscopy, and N2 adsorption/desorption isotherm analysis. The results demonstrated that the as-prepared mesoporous Co3O4 has
Pushya A Potnis et al.
Cellular immunology, 282(1), 53-65 (2013-05-18)
Metal orthopedic implant debris-induced osteolysis of hip bone is a major problem in patients with prosthetic-hips. Although macrophages are the principal targets for implant-wear debris, the receptor(s) and mechanisms underlying these responses are not fully elucidated. We examined whether the
Douglas A Weigent
Cellular immunology, 282(1), 9-16 (2013-05-04)
We report here that culture of lymphoid cells under hypoxic conditions showed an increase in both luciferase expression from a GH-promoter luciferase construct and the levels of lymphocyte GH. The effect was mimicked by treatment of cells with cobalt chloride
Ryota Shizu et al.
Toxicology letters, 219(2), 143-150 (2013-03-27)
Hypoxia inducible factor (HIF) and 5'-AMP-activated protein kinase are often activated under similar physiological conditions. Constitutive androstane receptor (CAR) translocates into the nucleus in accordance with 5'-AMP-activated protein kinase and thus confers transactivation. The aim of the present study was

Artículos

Biomedical implants are essentially foreign substances within the human body that must survive many years’ exposure to demanding mechanical and physiological conditions. Despite these challenges, metal implants have been widely used to substitute for or rebuild hard tissues such as bones and teeth.

Preguntas

Revisiones

Sin puntuación

Filtros activos

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico