We have not performed extractables/leachables studies for our Stericup® filters.
SEGPU0538
Unidad de filtración Stericup® E-GP ecológica
pore size 0.22 μm, polyethersulfone membrane, capacity 500 mL, 38 mm (1 1/2 in.) thread, pack of 12 ea
Sinónimos:
Sistema de filtración al vacío estéril sin embudo Stericup® E-GP Quick Release-GV
About This Item
Productos recomendados
Materiales
polyethersulfone membrane
polystyrene bottle
polystyrene funnel(s)
polystyrene housing
Nivel de calidad
esterilidad
sterile; irradiated
Línea del producto
Stericup®
Características
hydrophilic
envase
pack of 12 ea
características de los productos alternativos más sostenibles
Waste Prevention
Learn more about the Principles of Green Chemistry.
sustainability
Greener Alternative Product
Parámetros
max. temp. at 45 °C
descripción
2.4 mL (hold-up volume)
técnicas
sterile filtration: suitable
Altura
193 mm
capacidad
500 mL
Diámetro
9.3 cm
filtro capacidad
500 mL
diám. del filtro
73 mm
filtración área
40 cm2
Matriz
Express PLUS™
tamaño de poro
0.22 μm pore size
Adaptador
inlet thread(s)
38 mm (1 1/2 in.) thread
categoría alternativa más sostenible
Condiciones de envío
ambient
Descripción general
Para obtener más información, visite la BASE DE DATOS ACT
Los filtros esterilizantes Stericup® E y Steritop® E están diseñados como una Alternativa más Ecológica para la esterilización mediante filtración al vacío que reduce de manera significativa el plástico y los envases.
Este Stericup® E es un collarín de rosca de 38 mm que tiene una membrana de filtración de polietersulfona (PES) con un tamaño de poro de 0,22 μm combinada con un matraz receptor de 500 ml y una tapa para el procesamiento y almacenamiento. La rosca de 38 mm se conecta directamente a nuestras botellas de medios y a la mayoría de otras botellas de medios comerciales estándar.
Use solo botellas de vidrio o plástico diseñadas para aplicaciones al vacío.
Aplicación
- Medios de cultivo de tejidos +/- aditivos
- Amortiguadores
- Disoluciones biológicas
Características y beneficios
- El collar del filtro se desconecta de la botella receptora con solo un cuarto de vuelta—reduciendo así la probabilidad de derrame y haciendo que sea más fácil su manipulación sobre la mesa de trabajo o debajo de la campana.
- La identificación del producto en negrita en el collarín del filtro muestra claramente las características de la membrana, como su composición y el tamaño de los poros, para una selección de productos rápida y apropiada para la aplicación.
- El tapón de cierre mediante un clic está bridado y modificado para permitir un fuerte agarre en condiciones húmedas o secas—y un tope táctil confirma un cierre seguro. Preocúpese menos de la posibilidad de derramamiento o contaminación de los contenidos esterilizados.
- Una amplia superficie esmerilada de escritura en la botella receptora y el color más claro de la tapa facilita el etiquetado claro para mejorar la legibilidad y reducir los frotis ilegibles.
- La tapa descansa sobre el lateral para evitar el riesgo de contaminación.
- Las botellas receptoras son apilables para ahorrar espacio de almacenamiento.
Información legal
Opcional
Producto relacionado
Certificados de análisis (COA)
Busque Certificados de análisis (COA) introduciendo el número de lote del producto. Los números de lote se encuentran en la etiqueta del producto después de las palabras «Lot» o «Batch»
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Los clientes también vieron
Artículos
Learn about the impact of filtration on hematopoietic cell culture media containing vital T cell factors and other media components.
Learn about the impact of filtration on hematopoietic cell culture media containing vital T cell factors and other media components.
Learn about the impact of filtration on hematopoietic cell culture media containing vital T cell factors and other media components.
Learn about the impact of filtration on hematopoietic cell culture media containing vital T cell factors and other media components.
Contenido relacionado
Stericup® E and Steritop® E sterile filters help reduce laboratory environmental impact by significantly reducing plastic and packaging waste. Both attach directly to commercial media bottles, eliminating the plastic funnel while they eliminate contaminants from media and buffers.
Stericup® E and Steritop® E sterile filters help reduce laboratory environmental impact by significantly reducing plastic and packaging waste. Both attach directly to commercial media bottles, eliminating the plastic funnel while they eliminate contaminants from media and buffers.
Stericup® E and Steritop® E sterile filters help reduce laboratory environmental impact by significantly reducing plastic and packaging waste. Both attach directly to commercial media bottles, eliminating the plastic funnel while they eliminate contaminants from media and buffers.
Stericup® E and Steritop® E sterile filters help reduce laboratory environmental impact by significantly reducing plastic and packaging waste. Both attach directly to commercial media bottles, eliminating the plastic funnel while they eliminate contaminants from media and buffers.
-
What leachables are detected during filtration processes using Stericup® filters?
1 answer-
Helpful?
-
-
What tubing can be used with Stericup® and Steritop® vacuum filters?
What tubing can be used with Stericup® and Steritop® vacuum filters?
1 answer-
Stericup® and Steritop® filters are fitted with a 1/4” tube adapter. We recommend 3/16 in. (4.8 mm) ID silicone tubing to fit this tube adapter: https://www.sigmaaldrich.com/product/mm/xx7100004
Helpful?
-
-
What is the difference between classic Stericup® filters and Stericup® “Quick Release” filters?
1 answer-
Stericup® Quick Release, or “QR”, filters feature a connection between funnel filter and receiver bottle that requires only a quarter-turn release to facilitate funnel removal. These filters come fully engaged – there is no need to tighten before use. The receiver bottle cap has flanges on the top surface to improve grip, as well as a positive lock stop to ensure a leak-proof seal with the receiver bottle. Other improvements include a large, frosted writing surface on the receiver bottle and a lighter cap color to facilitate labelling, more prominent volume markings on the filtration funnel and receiver bottle, and a product label with a peel-off lot record strip on the bag for easy viewing in storage.
Helpful?
-
-
Can we filter oil-type liquids with Stericup® filters?
Can we filter oil-type liquids with Stericup® filters?
1 answer-
Likely not, due to pore size/possible fouling/chemical compatibility. Refer to our guide, "Chemical compatibility of filter components": https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/302/855/membrane-chemical-compatibility-ds2532en-ms.pdf
Helpful?
-
-
Can Stericup® and Steritop® filters be used to prepare solutions that will be administered to patients?
1 answer-
No, all Stericup® and Steritop® devices are Research Use Only.
Helpful?
-
-
Can Stericup® and Steritop® filters be reused?
1 answer-
All Stericup® and Steritop® filters were developed for single use, disposable processing.
Helpful?
-
-
What is the maximum vacuum pressure for filtration?
1 answer-
700 mm Hg (27.5” Hg, 0.9 bar) differential vacuum at 25 °C (77 °F)
Helpful?
-
-
What Bacterial Endotoxins Test is used?
1 answer-
The test method used complies with USP 85 and EP 2.6.14 to ensure the absence of endotoxin in our products.
Helpful?
-
-
What is the maximum processing volume for Stericup® and Steritop® filters? Can I add more volume after initial filtration?
1 answer-
All Stericup® and Steritop® filters were developed for single-use application. The maximum volume is dependent on the receiver bottle capacity. Stericup® filters come with a receiver bottle with a specified maximum volume. For Steritop® filters, the maximum recommended volume is 2 L with an appropriate-sized receiver bottle. Larger processing volumes can result in membrane fouling, increase chance of spillage and contamination, and lead to possible airlock*.
*Note that devices with PES membranes can airlock if filtered to dryness. Some liquid must be left on top of the filter, then the system stopped, receiver changed or emptied, and more sample volume added before restart. This increases the chance of spillage.Helpful?
-
-
What is the expiration date of Stericup® and Steritop® filters?
1 answer-
Typically 3 years from sterilization.
Helpful?
-
Active Filters
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico